Rajnandgaon District Panchayats Tricycle/Rickshaw Tender 2025 V2 - Generic Driving/Construction Standards
Rajnandgaon District Panchayats
RAJNANDGAON, CHHATTISGARH
Bid Publish Date
02-Jan-2026, 5:11 pm
Bid End Date
17-Jan-2026, 1:00 pm
EMD
₹34,17,500
Value
₹17,08,75,000
Location
Progress
Quantity
26
Bid Type
Two Packet Bid
Government Medical College And Hospital invites bids for ICU Ventilators (V2) (Q2) in CHANDIGARH, CHANDIGARH. Quantity: 26. Submission Deadline: 17-01-2026 13: 00: 00. Submit your proposal before the deadline.
Rajnandgaon District Panchayats
RAJNANDGAON, CHHATTISGARH
Satara District Panchayats
SATARA, MAHARASHTRA
Satara District Panchayats
SATARA, MAHARASHTRA
N/a
KANGRA, HIMACHAL PRADESH
Indian Army
EAST SIKKIM, SIKKIM
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| GENERAL | Product Description | ICU Ventilator |
| PRODUCT INFORMATION | Patient Type | Adult & pediatric |
| PRODUCT INFORMATION | Type of technology | Compressor |
| PRODUCT INFORMATION | Tidal volume in ml | (20 ml or less) to (1500 ml or more) |
| PRODUCT INFORMATION | Respiration rate, breaths/min | upto 150 or more |
| PRODUCT INFORMATION | Trigger mechanism | Both pressure and flow |
| PRODUCT INFORMATION | FiO2% | 21 to 100 |
| PRODUCT INFORMATION | Inspiratory flow rate, L/min | up to 150 or more |
| PRODUCT INFORMATION | Inspiratory pressure, cm H2O | upto 80 or more |
| PRODUCT INFORMATION | IE ratio | 1:10 to 4:1 |
| PRODUCT INFORMATION | Sigh breath function | Yes |
| PRODUCT INFORMATION | PEEP/CPAP, cm H2O | upto 40 or more |
| PRODUCT INFORMATION | Pressure support, cm H2O | 0 to 40 or more |
| PRODUCT INFORMATION | Leak compensation | Yes |
| PRODUCT INFORMATION | Auto 100%/Increase O2 button | Yes |
| PRODUCT INFORMATION | Control panel lock | Yes |
| PRODUCT INFORMATION | Facility for double lung ventilation | Yes |
| PATIENT ASSESSMENT TOOLS | Number of loops | 2 loops (P-V, F-V) with facility of saving of 1 Loops for reference |
| PATIENT ASSESSMENT TOOLS | Lung recruitment tools (PV loops) / OLT (Open lung tools) | Yes |
| PATIENT ASSESSMENT TOOLS | Lung mechanics visualization tool | Yes |
| PATIENT ASSESSMENT TOOLS | Capnography/CO2 monitoring | Yes |
| PATIENT ASSESSMENT TOOLS | Esophageal / transpulmonary pressure monitoring | No, Yes |
| PATIENT ASSESSMENT TOOLS | APRV(Airway Pressure Release Ventilation) /Bivent/Bi level | Yes |
| PATIENT ASSESSMENT TOOLS | MMV(Mandatory Minute Ventilation) + PSV (Pressure Support Ventilation) /ASV( Adaptive Support Ventilation ) or ALPV(Adaptive Lung Protection Ventilation) or Automode | Yes |
| PATIENT ASSESSMENT TOOLS | PRVC(Pressure-Regulated Volume Control ventilation)/Auto flow | Yes |
| PATIENT ASSESSMENT TOOLS | High flow oxygen therapy | Yes |
| PATIENT ASSESSMENT TOOLS | Automatic weaning system provided | Yes |
| PATIENT ASSESSMENT TOOLS | Volume Support | Yes |
| PATIENT ASSESSMENT TOOLS | Ventilation monitoring facility | The Ventillator is a Microprocessor Controlled ventilator with integrated facility for Ventilation monitoring |
| PATIENT ASSESSMENT TOOLS | Monitored / Displayed parameters | Peak inspiratory pressure, Mean airway pressure, PEEP pressure, Tidal volume, Minute volume, Spontaneous minute volume, FiO2 (analyzed %), Respiratory rate, Inspiratory time, Expiratory time, IE ratio, Plateau Pressure |
| PATIENT ASSESSMENT TOOLS | Availability of Status indicator on display | Ventilator mode, Battery life, patient data, alarm settings, clock |
| PATIENT ASSESSMENT TOOLS | Patient alarms | Low/high FiO2, Low/high minute volume, Low inspiratory pressure, High pressure, Low PEEP, High PEEP, Apnea, Continuous high pressure/occlusion, Inverse IE, High respiratory rate, Breathing circuit disconnect |
| PATIENT ASSESSMENT TOOLS | Equipment alarms | Gas-supply failure, Power failure, Vent inoperative, Low battery, Self-diagnostic |
| PATIENT ASSESSMENT TOOLS | RSBI (Rapid Shallow Breathing Index) | Yes |
| PATIENT ASSESSMENT TOOLS | Expiratory Time constant ( Tcexp) | Yes |
| PATIENT ASSESSMENT TOOLS | Compliance static and/or dynamic | Yes |
| PATIENT ASSESSMENT TOOLS | Inspired and/or expired resistance | Yes |
| PATIENT ASSESSMENT TOOLS | Occlusion pressure | Yes |
| PATIENT ASSESSMENT TOOLS | Inspiratory and expiratory hold | Yes |
| PATIENT ASSESSMENT TOOLS | Spontaneous frequency | Yes |
| PATIENT ASSESSMENT TOOLS | Total peep, intrinsic peep, extrinsic peep | Yes |
| PATIENT ASSESSMENT TOOLS | Expiratory block is autoclavable and no routine calibration required | Yes |
| PATIENT ASSESSMENT TOOLS | Auto compensation for ET Tube | Yes |
| PATIENT ASSESSMENT TOOLS | Facility for automatic compliance & Leakage compensation for circuit available | Yes |
| PATIENT ASSESSMENT TOOLS | RS 232 out put port | Yes |
| PATIENT ASSESSMENT TOOLS | USB/Memory card | Yes |
| PATIENT ASSESSMENT TOOLS | Availability of Remote alarm/display port | Yes |
| PATIENT ASSESSMENT TOOLS | Facility to Report (vent alarms and patient status) | Yes |
| PATIENT ASSESSMENT TOOLS | HL/7 Compliant out put | Yes |
| PATIENT ASSESSMENT TOOLS | Type of coloured display | LED/LCD/TFT |
| PATIENT ASSESSMENT TOOLS | Display should be touch screen | Yes |
| PATIENT ASSESSMENT TOOLS | NIV (Non Invasive Ventilation) to be possible in all modes of ventilation available | Yes |
| PATIENT ASSESSMENT TOOLS | Minimum Size of display (±2%) | 15.0 |
| PATIENT ASSESSMENT TOOLS | Graphic display have automatic scaling facility for waves | Yes |
| HARDWARE AND ELECTRICAL REQUIREMENTS | Power supply | 220-240 V , 50 Hz AC |
| HARDWARE AND ELECTRICAL REQUIREMENTS | Provision of UPS | Yes, No |
| HARDWARE AND ELECTRICAL REQUIREMENTS | Backup time in hrs | 2 |
| HARDWARE AND ELECTRICAL REQUIREMENTS | Internal backup battery | Yes |
| HARDWARE AND ELECTRICAL REQUIREMENTS | Backup time of internal battery in mins | 30 mins or more |
| HARDWARE AND ELECTRICAL REQUIREMENTS | Built in air source | Air compressor (external) |
| HARDWARE AND ELECTRICAL REQUIREMENTS | Availability of stand alone compressor | Yes |
| HARDWARE AND ELECTRICAL REQUIREMENTS | Compressor shall provide an oil free Medical air, with Peak output flow should be minimum 150 LPM and Air quality complying with ISO compressed air purity class | Yes |
| HARDWARE AND ELECTRICAL REQUIREMENTS | Medical Air Compressor should automatically activate in the event of wall air supply loss and replacement of internal filters should be performed without removing the compressor, to have washable air filter | Yes |
| HARDWARE AND ELECTRICAL REQUIREMENTS | Seller shall ensure compatibility of compressor with ventilator | Yes |
| HARDWARE AND ELECTRICAL REQUIREMENTS | Nebulizer with particle size less than 3 micron | Yes |
| ADDITIONAL ACCESSORIES | NV mask(Re usable)-Small,medium and large | 2 Each |
| ADDITIONAL ACCESSORIES | Length of Power cord in m | ≥ 3 m |
| ADDITIONAL ACCESSORIES | Humidifier: Servo controlled with digital monitoring of inspired gas temperature with heating wire | 1 |
| ADDITIONAL ACCESSORIES | Trolley for ventilator with circuit holding arm | Yes |
| CERTIFICATIONS | Compliance to Medical Device Rules (MDR) 2017 as amended till date | Yes |
| CERTIFICATIONS | Availability of valid Medical Device license for the product issued from the competent authority defined under Drugs and Cosmetic Act 1940 and Rules made there under as amended till date | Yes |
| CERTIFICATIONS | Certification for manufacturing unit | ISO:13485 (Latest) |
| CERTIFICATIONS | Availability of Test Report for each supplied batch/product as per Medical Device Rule (MDR) 2017 as amended till date | Yes |
| CERTIFICATIONS | Submission of all necessary certifications, licenses and test reports to the buyer at the time of bid submission or along with supplies as per buyer requirement | Yes |
| CERTIFICATIONS | Electrical Safety Standard | IEC 60601-1-2 or Equivalent BIS |
| CERTIFICATIONS | Safety and Essential Performance | IS 13450 Part 2 Section 12 |
| MISCELLANEOUS PARAMETERS | OEM/Reseller (if supplied by reseller shall ensure uninterrupted availability of all spares for 10 years) | Yes |
| MISCELLANEOUS PARAMETERS | Availability of toll free facility for technical support maintened by OEM or authorized agencies | Yes |
| MISCELLANEOUS PARAMETERS | During the warranty period it shall be ensured that all the break down calls are attended with in 24 hrs and the complete details of service agents / contact details should be furnished to buyer and consignee at time of supplies | Yes |
| MISCELLANEOUS PARAMETERS | User/Technical/Maintenance manuals to be supplied in English in hard and soft copy | Yes |
| MISCELLANEOUS PARAMETERS | Details of equipments and procedures required for local calibration and routine maintenance to be supplied and advanced maintenance task documentation also to be furnished | Yes |
| MISCELLANEOUS PARAMETERS | List of important spares and accessories, with their part numbers and price lists to be supplied to the buyer at the time of supplying the equipment | Yes |
| MISCELLANEOUS PARAMETERS | The Principal Manufacturer must have direct Presence/approved service center In India | Yes |
| MISCELLANEOUS PARAMETERS | Copies of reports and certifications to be furnished to buyer on demand at time of supplies | Yes |
| WARRANTY | Warranty (years) | 5 Or higher |
Discover companies most likely to bid on this tender
Experience Criteria
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
Additional Doc 1 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Indian Army
📍 UDHAMPUR, JAMMU & KASHMIR
All India Institute Of Medical Sciences (aiims)
📍 SOUTH DELHI, DELHI
Directorate Of Technical Education And Training
N/a
📍 ALMORA, UTTARAKHAND
Indian Navy
📍 TIRUNELVELI, TAMIL NADU
Sign up now to access all documents
Main Document
OTHER
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS