TenderDekho Logo
GEM

Procurement Opportunity: Ion selective electrode in MUMBAI, MAHARASHTRA

Bid Publish Date

16-Jun-2026, 11:46 am

Bid End Date

07-Jul-2026, 9:00 am

Progress

Issue16-Jun-2026, 11:46 am
AwardPending
Explore all 4 tabs to view complete tender details

Quantity

2

Bid Type

Single Packet Bid

Directorate Of Purchase And Stores announces a tender for Ion selective electrode (Q3) ( PAC Only) in MUMBAI, MAHARASHTRA. Quantity: 2. Submission Deadline: 07-07-2026 09: 00: 00. Last date to apply is approaching fast!

Additional Tender Data

Commercial Details

Tender Category

Goods

Bid To RA

No

Bid To RA Enabled

No

Item Category

Ion selective electrode (Q3) ( PAC Only )

Authority Records

DEPARTMENT OF ATOMIC ENERGY

BID & GeM Expert Consultancy

End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.

Bid Preparation GeM Registration Document Filing

Free consultation · 24h response

Documents 5

GeM-Bidding-9416671.pdf

Main Document

Other Documents

OTHER

CATALOG-Specification-1

CATALOG Specification

Buyer uploaded ATC document

ATC

GEM General Terms and Conditions Document

GEM_GENERAL_TERMS_AND_CONDITIONS

Past Similar Tenders (Historical Results)

5 found

Directorate Of Purchase And Stores Ion Selective Electrodes Tender 2025 Department Of Atomic Energy India

Directorate Of Purchase And Stores

Posted: 25 November 2025
Closed: 9 December 2025
GEM

Ion selective electrode

Directorate Of Purchase And Stores

Posted: 26 May 2025
Closed: 10 June 2025
GEM

Ion selective electrode

Central Water Commission (cwc)

SURAT, GUJARAT

Posted: 7 January 2025
Closed: 18 January 2025
GEM

Ion selective electrode

Central Water Commission (cwc)

Posted: 25 November 2024
Closed: 12 December 2024
GEM

Ion selective electrode

Directorate Of Purchase And Stores

Posted: 16 May 2025
Closed: 30 May 2025
GEM

Technical Specifications 1 Item

Item #1 Details

View Catalog
Category Specification Requirement
Generic Item Description Only Ion Selective electrode with accessories
Measurements Possible Measurements ions
Performance Parameter Ion Electrodes Nitrate ion
Performance Parameter Features Microprocessor based, Menu driven programmable, Multiple channel for direct measurement of Ion Conc mV, pH and Temp, Up gradation to analyze multi parameters, Bench top model for analysis of all cations and anions at residual level, Large backlit graphic LCD display, Easy function keys for easy selection, Ready indicator alerts for indicating when readings are stable, Timed reading gathers data in specific time intervals or just once with single short mode, Fix errors without a complete recalibration with the calibration editing function, Atleast 5 methods per channel and allowing customized procedures to differentiate between tests and/or users, Facility to transfer data from equipment to computer archives, Directly operate the ion meter with PC with suitable software, Facility to mix samples with a stir plate with direct control of the stirrer probe, Machine should Include electrode arm and probe holder to make it easier to maintain and place probes into samples, Should works with almost every AC power source, Ion meter should include Propeller stirrer with variable speed for Stirring controlled, Should provide additional Electrode Stand, Others, USB output, Powered with power adapter, In places without power supply possibility of work with an external rechargeable battery, HOLD" function to freeze the result on the display, NA
Technical Specifications Power Supply 9 V / 500 mA power adapter
Technical Specifications Electrodes Single Channel
Technical Specifications Calibration Points-Min 3
Technical Specifications Rechargable Battery NA
Technical Specifications Ion Meter Series 500 Series
Ion Selective Electrode Ion measurement mode specifications Enables ion concentration measurements of monovalent, bivalent, negative and positive ions
Ion Selective Electrode Range-ISE 0 to 19999
mV - Rel mV Relative Accuracy +/-0.2 mV or 0.05%, whichever is greater
pH Measuring Mode pH mode specifications NA
Temperature Readable Units NA
Data Logging Log function Manual, ready and time
Warranty Warranty Duration 12.0 - 36.0 Or higher
Manintainence Contract AMC 0.0
Documentation Complete Tabular Details with specific Measurement chart as per Model No
Certifications and Reports Copies of reports and certifications to be furnished to buyer on demand at time of supplies No

🤖 AI-Powered Bidder Prediction

Discover companies most likely to bid on this tender

Live AI
Historical Data

Required Documents

1

Certificate (Requested in ATC)

2

OEM Authorization Certificate *In case any bidder is seeking exemption from Experience / Turnover Criteria

3

the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer

Similar Tenders

5 found
Urgent

Odisha Mining Corporation Limited Carbon Electrode Paste Tender Bhubaneswar Odisha 2026

Odisha Mining Corporation Limited (omc) Bhubaneswar

📍 JAJAPUR, ODISHA

EMD: ₹4.0 L
⏰ Deadline: 6 days left
🛒 Type: Goods
View GEM
Urgent

ECG Electrode Gel (V2),ECG Electrodes (V2)

Employees State Insurance Corporation (esic)

📍 GULBARGA, KARNATAKA

⏰ Deadline: 3 days left
🛒 Type: Goods
View GEM

Portable Multi-Parameter with ion Electrode

Directorate Of Purchase And Stores

⏰ Deadline: 3 weeks left
🛒 Type: Goods
View GEM
Urgent

National Institute Of Technology Raipur Electrochemical Workstation Tender 2026 Raipur Chhattisgarh IS 550/ISO Standards 3 Years Experience

National Institute Of Technology (nit)

📍 RAIPUR, CHHATTISGARH

EMD: ₹78,000
Est: ₹26.0 L
⏰ Deadline: 4 days left
🛒 Type: Goods
View GEM
Urgent

ECG Electrodes (V2)

Indian Army

📍 JALANDHAR, PUNJAB

⏰ Deadline: 5 days left
🛒 Type: Goods
View GEM