TenderDekho Logo
GEM

Government Tender Published for SPECTROPHOTOMETER in BHAGALPUR, BIHAR

Bid Publish Date

02-Jul-2026, 11:20 am

Bid End Date

13-Jul-2026, 12:00 pm

Location

BHAGALPUR , BIHAR

Progress

Issue02-Jul-2026, 11:20 am
AwardPending
Explore all 4 tabs to view complete tender details

Quantity

1

Bid Type

Two Packet Bid

Categories 18

Public procurement opportunity for Bihar Agricultural University SPECTROPHOTOMETER (Q2) in BHAGALPUR, BIHAR. Quantity: 1 issued by. Submission Deadline: 13-07-2026 12: 00: 00. View full details and respond.

Additional Tender Data

Commercial Details

Tender Category

Goods

Bid To RA

No

Bid To RA Enabled

No

Item Category

SPECTROPHOTOMETER (Q2)

Authority Records

AGRICULTURE DEPARTMENT

BID & GeM Expert Consultancy

End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.

Bid Preparation GeM Registration Document Filing

Free consultation · 24h response

Documents 3

GeM-Bidding-9529658.pdf

Main Document

CATALOG-Specification-1

CATALOG Specification

GEM General Terms and Conditions Document

GEM_GENERAL_TERMS_AND_CONDITIONS

Past Similar Tenders (Historical Results)

5 found

SPECTROPHOTOMETER

Rajiv Gandhi Centre For Biotechnology (rgcb)

THIRUVANANTHAPURAM, KERALA

Posted: 29 May 2025
Closed: 11 June 2025
GEM

SPECTROPHOTOMETER

Department Of Drugs Control

Posted: 11 November 2024
Closed: 21 November 2024
GEM

SPECTROPHOTOMETER

Indian Institutes Of Science Education And Research (iiser)

GANJAM, ODISHA

Posted: 9 January 2025
Closed: 30 January 2025
GEM

SPECTROPHOTOMETER

N/a

JAUNPUR, UTTAR PRADESH

Posted: 11 January 2025
Closed: 1 February 2025
GEM

SPECTROPHOTOMETER

National Institute Of Technology (nit)

BHOPAL, MADHYA PRADESH

Posted: 14 January 2025
Closed: 4 February 2025
GEM

Technical Specifications 1 Item

Item #1 Details

View Catalog
Category Specification Requirement
LIGHT SOURCE Light Source Deuterium Lamp, Tungsten Halogen Lamp
LIGHT SOURCE Diffraction Grating (lines/mm) 1200
LIGHT SOURCE Switching of Light Source Automatic
LIGHT SOURCE Wavelength Setting And Scanning Automatic
TYPE Type of Spectrophotometer UV - VISIBLE
TYPE Type of Optical System Double Beam
TYPE Monochromator Type Czerny-turner
TYPE Detector Type Photo Multiplier Tube (PMT)
TYPE Spectral Bandwidth Type Variable Bandwidth
OPTICAL PERFORMANCE Source Wavelength - Minimum 190.0
OPTICAL PERFORMANCE Source Wavelength - Maximum 1100, 1500, 2000, 2500, 2700, 3000, 3200, 3300, 1650 Or higher
OPTICAL PERFORMANCE Resolution 0.3
OPTICAL PERFORMANCE Wavelength Accuracy (+/-) 0.1
OPTICAL PERFORMANCE Bandwidth (nm) 0.1 to 5.0
OPTICAL PERFORMANCE Focal length (mm) 100 to 149
OPTICAL PERFORMANCE Photometric measurement modes Transmittance, Absorbance, Concentration (Wavelength, time), Reflectance, Energy
OPTICAL PERFORMANCE Photometric Absorbance (Max) (Abs) (+/-) 4
OPTICAL PERFORMANCE Photometric Absorbance Accuracy (Max) (+/-) 0.001 - 0.001 Or lower
OPTICAL PERFORMANCE Photometric Transmittance (Max) (+/-) 100.0
OPTICAL PERFORMANCE Photometric Transmittance Accuracy (Max) (+/-) 0.0 - 0.1 Or lower
OPTICAL PERFORMANCE Photometric Reflectance (Max) (+/-) 100.0
GENERIC Display In-built display
GENERIC Display type TFT
GENERIC Display Size 10.1 - 30.0 Or higher
GENERIC Test result printing Through external printer
GENERIC If inbuilt printer, Type of printer Laser b/w
GENERIC Internal storage(GB) 1.0 - 80.0 Or higher
GENERIC Mximum Path Length of sample 100.0
GENERIC Number of Cuvettes supplied-inclusive in the scope of supply 6
GENERIC Spares and Consumables inclusive in the scope of supply No
OPERATING CONDITIONS Minimum Operating Temperature 10.0
OPERATING CONDITIONS Maximum Operating Temperature 35.0
OPERATING CONDITIONS Operating Humidity (RH) (%) at 40 degree C 80.0
WARRANTY Onsite Warranty 2.0
WARRANTY Availability of Spares (at extra cost) 10.0
Certification Availability of UL/CE Certification as per EN 61010-1:2010 Safety requirements for electrical equipment for measurement, control, and laboratory use General requirements Yes
Certification Conformance to EMC/EMI as per EN 61326-1:2013 Electrical equipment for measurement, control and laboratory use No
Certification Availability of Test Reports from Central Govt / NABL approved / ILAC acredited lab to prove conformity to the specification No

🤖 AI-Powered Bidder Prediction

Discover companies most likely to bid on this tender

Live AI
Historical Data

Required Documents

1

Experience Criteria

2

Bidder Turnover

3

OEM Authorization Certificate *In case any bidder is seeking exemption from Experience / Turnover Criteria

4

the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer

Similar Tenders

5 found
Urgent

SPECTROPHOTOMETER

State Forensic Science Laboratory Chhattisgarh

📍 RAIPUR, CHHATTISGARH

EMD: ₹40,000
⏰ Deadline: 1 day left
🛒 Type: Goods
View GEM
Urgent

Sher-e-Kashmir University Of Agricultural Sciences And Technology Of Jammu Spectrophotometer Tender Jammu 61010-1 EN 61010-1 2010 2026

Sher-e-kashmir University Of Agricultural Sciences And Technology Of Jammu

📍 JAMMU, JAMMU & KASHMIR

EMD: ₹26,000
⏰ Deadline: 4 days left
🛒 Type: Goods
View GEM
Urgent

SPECTROPHOTOMETER

National Institute Of Technology (nit)

📍 HAMIRPUR, HIMACHAL PRADESH

⏰ Deadline: 4 days left
🛒 Type: Goods
View GEM

SPECTROPHOTOMETER

Jawaharlal Institute Of Postgraduate Medical Education And Research (jipmer)

📍 PONDICHERRY, PUDUCHERRY

Est: ₹12.0 L
⏰ Deadline: 3 weeks left
🛒 Type: Goods
View GEM

SPECTROPHOTOMETER

Office Of Dg ( Ns & M)

EMD: ₹1.4 L
⏰ Deadline: 2 weeks left
🛒 Type: Goods
View GEM