Public procurement opportunity for Government Medical College And Hospital Laparoscopic Surgery System (V2) (Q2) in CHANDIGARH, CHANDIGARH. Quantity: 1 issued by. Submission Deadline: 05-03-2026 10: 00: 00. View full details and respond.
Main Document
OTHER
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Directorate Of Medical Education And Training
JAUNPUR, UTTAR PRADESH
Ssg Hospital Vadodara
N/a
N/a
U.p.rural Institute Of Medical Sciences And Research Saifai
ETAWAH, UTTAR PRADESH
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| GENERAL | Product Description | Laparoscopic Surgery System |
| GENERAL | Components of the laparoscopic set to be from the same OEM | Camera head, Camera console, Light source and cable, Telescope |
| CAMERA PROCESSOR | Camera processor | 2D |
| CAMERA PROCESSOR | Resolution of camera in pixels | 3840 x 2160 (4K) |
| CAMERA PROCESSOR | Aspect ratio | 16:9 |
| CAMERA PROCESSOR | Image sensor | CMOS/CCD |
| CAMERA PROCESSOR | Special filters for chrome endoscopy | Yes Or higher |
| CAMERA PROCESSOR | Minimum Video output | 2 |
| CAMERA PROCESSOR | Minimum Number of programmable buttons on camera head | 3 |
| CAMERA PROCESSOR | Zoom facility | Yes |
| CAMERA PROCESSOR | The system capable of lCG fluoroscopy for better delineation of anatomic structures | Yes Or higher |
| CAMERA PROCESSOR | The camera head shall be sterilizable by autoclave or by some other appropriate technology | Yes |
| CAMERA PROCESSOR | Should be compatible with flexible video endoscope | Yes |
| HIGH-RESOLUTION MEDICAL GRADE MONITOR | Monitor type | 2D |
| HIGH-RESOLUTION MEDICAL GRADE MONITOR | Size of monitor in inches | 31 to 40 |
| HIGH-RESOLUTION MEDICAL GRADE MONITOR | Resolution of monitor in pixels | 3840 x 2160 (4K) |
| HIGH-RESOLUTION MEDICAL GRADE MONITOR | Aspect ratio of monitor | 16:9 |
| HIGH-RESOLUTION MEDICAL GRADE MONITOR | Panel shall be anti glare | Yes |
| HIGH-RESOLUTION MEDICAL GRADE MONITOR | Monitor shall have picture in picture facility | Yes |
| HIGH-RESOLUTION MEDICAL GRADE MONITOR | Provision of monitor stand with integrated cable channel for monitor | Yes |
| HIGH-RESOLUTION MEDICAL GRADE MONITOR | Minimum Video inputs | 2 |
| HIGH-RESOLUTION MEDICAL GRADE MONITOR | Minimum Video output of monitor | 2 |
| HIGH-RESOLUTION MEDICAL GRADE MONITOR | Viewing angle of monitor | 178 degree (H) and 178 degree (V) |
| HIGH-RESOLUTION MEDICAL GRADE MONITOR | Monitor should be PAL system compatible | Yes |
| HIGH-RESOLUTION MEDICAL GRADE MONITOR | Availability of output ports | Digital |
| HIGH-RESOLUTION MEDICAL GRADE MONITOR | Monitor is from the same OEM make | Yes |
| LIGHT SOURCE | Light Source Type | LED Lamp |
| LIGHT SOURCE | Lamp life | 10000 hours or more, 20000 hours or more Or higher |
| LIGHT SOURCE | Colour temperature of light source(Approx) | 5401 K to 6500 K Or higher |
| LIGHT SOURCE | Minimum LED Lamp intensity | 1500 Lumens or more, 1800 Lumens or more Or higher |
| LIGHT SOURCE | Means of light intensity adjustment facility | Continuously adjustable from 0 to 100% manually/automatically |
| LIGHT SOURCE | NIR filter for ICG application | Yes |
| FIBRE OPTIC LIGHT CABLE | Diameter in mm | 4.5 mm or above |
| FIBRE OPTIC LIGHT CABLE | Length in cm | 300 cm or above |
| FIBRE OPTIC LIGHT CABLE | Cable shall be autoclavable | Yes |
| FIBRE OPTIC LIGHT CABLE | Fibre cable shall be capable of transmitting the optimum light delivered by the light source | Yes |
| FIBRE OPTIC LIGHT CABLE | Cable shall have capability to with stand the high temperature | Yes |
| CO2 INSUFFLATOR | CO2 insufflator provided | Yes |
| CO2 INSUFFLATOR | Flow rate in Litre per minute | 40 or more |
| CO2 INSUFFLATOR | Pressure in mm Hg | 0 to 30 mmHg |
| CO2 INSUFFLATOR | Pre heating facility | Yes |
| CO2 INSUFFLATOR | Digital Display for actual and pre set flow rate and pressure and total volume consumed | Yes |
| CO2 INSUFFLATOR | Quick and precise continuous insufflation | Fully Microprocessor based |
| CO2 INSUFFLATOR | Machine should be able to set flow rateautomatically depending on actual abdomen pressure and set pressure | Yes |
| CO2 INSUFFLATOR | Provision of automatic venting mechanism | Yes |
| CO2 INSUFFLATOR | High pressure tubing with yoke assembly from machine to CO2 cylinder | Yes |
| CO2 INSUFFLATOR | Provision of patient tube with luer lock adaptor | Yes |
| CO2 INSUFFLATOR | CO2 insufflator should have visual and audible alarms | Yes |
| CO2 INSUFFLATOR | lt should also have provision of automatic feed back on malfunction & indicators on control panel | Yes |
| CO2 INSUFFLATOR | CO2 Insufflator should be from same OEM make | Yes |
| TELESCOPES | Telescope provided | Yes |
| TELESCOPES | Compatibility of telescope | 4K |
| TELESCOPES | NIR/ICG compatible | Yes |
| TELESCOPES | Quantity of 5-6 mm telescope (0 degree each) | 1, NA if not provided |
| TELESCOPES | Quantity of 5-6 mm telescope (30 degree each) | 1 |
| TELESCOPES | Quantity of 10-11 mm telescope (30 degree each) | 2 |
| TELESCOPES | Length of telescope in cm | 29 to 33 cm (Non Bariatic) |
| TELESCOPES | Facility of rod lens system for high definition imaging | Yes |
| TELESCOPES | Facility of standard ocular window for coupling the camera head | Yes |
| TELESCOPES | Telescope shall be autoclavable | Yes |
| TELESCOPES | Material of telescope | Medical grade stainless steel |
| DOCUMENTATION SYSTEM (RECORDER SYSTEM) | The system is compact and provided with medical grade recording device | Yes |
| DOCUMENTATION SYSTEM (RECORDER SYSTEM) | Type of recording system | 2D |
| DOCUMENTATION SYSTEM (RECORDER SYSTEM) | Provision for digital storage of still images, video sequences, and audio files Format available | 4K |
| DOCUMENTATION SYSTEM (RECORDER SYSTEM) | System is sterile, ergonomic operation via touch screen, camera head buttons / foot switch | Yes |
| DOCUMENTATION SYSTEM (RECORDER SYSTEM) | System has full featured Graphical User Interface DICOM capability | Yes |
| DOCUMENTATION SYSTEM (RECORDER SYSTEM) | Provision of Portable memory and USB slot for still image recording available | Yes |
| DOCUMENTATION SYSTEM (RECORDER SYSTEM) | Minimum internal memory | 1 TB, 2TB Or higher |
| DOCUMENTATION SYSTEM (RECORDER SYSTEM) | Live streaming facility | Yes |
| MOBILE VIDEOCART | Mobile Videocart should ride on four antistatic casters | Yes |
| MOBILE VIDEOCART | Availability of locking brakes | Yes |
| MOBILE VIDEOCART | Monitor arm provided with height adjustment | 1 |
| MOBILE VIDEOCART | Number of shelves | 4 |
| MOBILE VIDEOCART | Availability of handles for easy manoeuvring | Yes |
| MOBILE VIDEOCART | Cable channel mounted on the left or right of the column | Yes |
| ACCESSORIES | Online UPS 2 KVA | Yes, NA if not provided |
| CERTIFICATIONS | Compliance to Medical Device Rules (MDR) 2017 as amended till date | Yes |
| CERTIFICATIONS | Availability of valid Medical Device license for the product issued from the competent authority defined under Drugs and Cosmetic Act 1940 and Rules made there under as amended till date | Yes |
| CERTIFICATIONS | Certification for manufacturing unit | ISO:13485 (Latest) |
| CERTIFICATIONS | Conformity to standards for safety | IEC/EN 60601-1 or equivalent BIS Standard |
| CERTIFICATIONS | Submission of all necessary certifications, licenses and test reports to the buyer at the time of bid submission or along with supplies as per buyer requirement | Yes |
| WARRANTY | Warranty in Years (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) | 5 Or higher |
| MISCELLANEOUS REQUIREMENTS | Availability of toll free facility for technical support maintened by OEM or authorized agencies | Yes |
| MISCELLANEOUS REQUIREMENTS | User/Technical/Maintenance manuals to be provided in English in hard and soft copy | Yes |
| MISCELLANEOUS REQUIREMENTS | Details of equipments and procedures required for local calibration and routine maintenance to be provided and advanced maintenance task documentation also to be furnished | Yes |
| MISCELLANEOUS REQUIREMENTS | Supplier to perform installation, safety and operation checks before handover | Yes |
| MISCELLANEOUS REQUIREMENTS | Training of users in operation and basic maintenance shall be provided | Yes |
| MISCELLANEOUS REQUIREMENTS | Contact details of manufacturer, supplier and local service agent to be provided | Yes |
| MISCELLANEOUS REQUIREMENTS | Certificate of calibration from the manufacturer | Yes |
Discover companies most likely to bid on this tender
Experience Criteria
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
Additional Doc 1 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Extended Deadline
05-Mar-2026, 10:00 am
Opening Date
05-Mar-2026, 10:30 am
Brd Medical College Gorakhpur
📍 GORAKHPUR, UTTAR PRADESH
Uttarakhand Health And Family Welfare Society Dehradun
📍 HARIDWAR, UTTARAKHAND
N/a
📍 WEST TRIPURA, TRIPURA
Sign up now to access all documents
Main Document
OTHER
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS