SPECTROPHOTOMETER
Kamdhenu University
SABARKANTHA, GUJARAT
Bid Publish Date
24-Feb-2026, 4:24 pm
Bid End Date
06-Mar-2026, 5:00 pm
Location
Progress
Quantity
1
Bid Type
Single Packet Bid
Bidhan Chandra Krishi Viswavidyalaya Nadia invites bids for SPECTROPHOTOMETER (Q2) in NADIA, WEST BENGAL. Quantity: 1. Submission Deadline: 06-03-2026 17: 00: 00. Submit your proposal before the deadline.
Main Document
CATALOG Specification
GEM_GENERAL_TERMS_AND_CONDITIONS
Kamdhenu University
SABARKANTHA, GUJARAT
N/a
KORBA, CHHATTISGARH
N/a
NORTH 24 PARGANAS, WEST BENGAL
N/a
Indian Council Of Agricultural Research (icar)
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| LIGHT SOURCE | Light Source | Halogen Lamp, Deuterium Lamp, LED, Tungsten Halogen Lamp, Xenon Flash |
| LIGHT SOURCE | Diffraction Grating (lines/mm) | 600, 800, 1000, 1200, 1400, 1600, 1800 |
| LIGHT SOURCE | Switching of Light Source | Automatic, Mannual, NA |
| LIGHT SOURCE | Wavelength Setting And Scanning | Automatic |
| TYPE | Type of Spectrophotometer | UV-VIS |
| TYPE | Type of Optical System | Single Beam |
| TYPE | Monochromator Type | Reflexive Grating, Holographic Grating, Czerny-turner, NA, Scanning grating |
| TYPE | Detector Type | Photo Multiplier Tube (PMT), Photodiode, CMOS, Diode array, Silicon, Silicon & Lead Sulfide, Indium Gallium Arsenide (InGaAs) |
| TYPE | Spectral Bandwidth Type | Fixed Bandwidth, Variable Bandwidth |
| OPTICAL PERFORMANCE | Source Wavelength - Minimum | 190.0 |
| OPTICAL PERFORMANCE | Source Wavelength - Maximum | 1100, 1500, 2000, 2500, 2700, 3000, 3200, 3300, 1650 Or higher |
| OPTICAL PERFORMANCE | Resolution | 0.5, 0.3 |
| OPTICAL PERFORMANCE | Wavelength Accuracy (+/-) | 0.3, 1.0 |
| OPTICAL PERFORMANCE | Bandwidth (nm) | 1, 2.0 |
| OPTICAL PERFORMANCE | If variable band width, Specify the incremental step value(mm) | 1.0, NA |
| OPTICAL PERFORMANCE | Scanning Speed (nm/min) | 800, 2500 |
| OPTICAL PERFORMANCE | Focal length (mm) | 50 to 99, 100 to 149 |
| OPTICAL PERFORMANCE | Photometric measurement modes | Transmittance, Absorbance, Concentration (Wavelength, time), Reflectance, Energy, Polarisation |
| OPTICAL PERFORMANCE | Photometric Absorbance (Max) (Abs) (+/-) | 4, 0.2 |
| OPTICAL PERFORMANCE | Photometric Absorbance Accuracy (Max) (+/-) | 0.001 - 0.001 Or lower |
| OPTICAL PERFORMANCE | Photometric Transmittance (Max) (+/-) | 100.0, 0.0 |
| OPTICAL PERFORMANCE | Photometric Transmittance Accuracy (Max) (+/-) | 0.0 - 0.5 Or lower |
| OPTICAL PERFORMANCE | Photometric Reflectance (Max) (+/-) | 0.0 |
| OPTICAL PERFORMANCE | Photometric Reflectance Accuracy (Max) (+/-) | 0.0 - 0.5 Or lower |
| OPTICAL PERFORMANCE | Stray Light Correction | Automatic |
| OPTICAL PERFORMANCE | Baseline Correction | Automatic |
| GENERIC | Display | In-built display |
| GENERIC | Display type | LCD touchscreen |
| GENERIC | Display Size | 10.1 - 30.0 Or higher |
| GENERIC | Test result printing | Through external printer |
| GENERIC | If inbuilt printer, Type of printer | N/A |
| GENERIC | Suitable software for connecting PC & Printer | Yes |
| GENERIC | Connectivity | RS 232 |
| GENERIC | Internal storage(GB) | 4.0 - 80.0 Or higher |
| GENERIC | Sample switching/selection | Automatic |
| GENERIC | Capacity of Sample holder / Sample Carousel | 2 |
| GENERIC | Mximum Path Length of sample | 10.0 |
| GENERIC | Number of Cuvettes supplied-inclusive in the scope of supply | 2 |
| GENERIC | Power Supply | 230 V ± 10, 50 Hz |
| GENERIC | Spares and Consumables inclusive in the scope of supply | Yes, No |
| OPERATING CONDITIONS | Minimum Operating Temperature | -5, -10, 0, 5, 10 |
| OPERATING CONDITIONS | Maximum Operating Temperature | 35, 40, 45, 50, 55, 60 |
| OPERATING CONDITIONS | Operating Humidity (RH) (%) at 40 degree C | 80.0 |
| WARRANTY | Onsite Warranty | 1.0 |
| WARRANTY | Availability of Spares (at extra cost) | 5.0 |
| Certification | Availability of UL/CE Certification as per EN 61010-1:2010 Safety requirements for electrical equipment for measurement, control, and laboratory use General requirements | Yes, No |
| Certification | Conformance to EMC/EMI as per EN 61326-1:2013 Electrical equipment for measurement, control and laboratory use | Yes, No |
| Certification | Availability of Test Reports from Central Govt / NABL approved / ILAC acredited lab to prove conformity to the specification | Yes, No |
| Certification | If yes test report to furnished,to the buyer on demand | N/A |
Discover companies most likely to bid on this tender
Experience Criteria
OEM Authorization Certificate *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Rajiv Gandhi University
📍 PAPUM PARE, ARUNACHAL PRADESH
Office Of Dg (ls)
Kamdhenu University
📍 BANASKANTHA, GUJARAT
Directorate Of Medical Education And Training
📍 AGRA, UTTAR PRADESH
Secretariat Department Of He St And Bt West Bengal
📍 KOLKATA, WEST BENGAL
Sign up now to access all documents
Main Document
CATALOG Specification
GEM_GENERAL_TERMS_AND_CONDITIONS