Progress
Directorate Of Employment & Training announces a tender for FREQUENCY METER DIGITAL, ELECTRICAL LOAD SET OF INCANDESCENT LAMP TUBE LIGHT CFL LED, ARRAY JUNCTION BOX FOR CONNECTING 250W X 4 NOS. SOLAR PANEL, ELECTRICAL WIRING AND SWITCH GEAR RACK, DISCRETE COMPONENT TRAINER, PROTECTIVE RELAYS AND CONTACTORS RACK in JAMNAGAR, GUJARAT. Quantity: 8. Submission Deadline: 22-10-2026 18: 00: 00. Last date to apply is approaching fast!
Quantity
8
Category
DISCRETE COMPONENT TRAINER
Bid Type
Two Packet Bid
Bid Validity
180 (Days)
Bid Type
Service
Evaluation
Total value wise evaluation
Inspection Required
No
RA Qualification Rule
H1-Highest Priced Bid Elimination
Tech Clarification Time
2 Days
EMD Required
No
MII Purchase Preference
Yes
MII Preference Band
L1+20%
MSE Purchase Preference
Yes
MSE Preference Band
L1+20%
MSE Exemption/Relaxation
No
Startup Exemption/Relaxation
Yes
Bid Splitting Applied
No
OEM Avg. Turnover
1
Past Performance
50 %
Warranty Period
15 days
Experience Required
3 Year (s)
Arbitration Clause
No
Mediation Clause
No
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
FREQUENCY METER DIGITAL , ELECTRICAL LOAD SET OF INCANDESCENT LAMP TUBE LIGHT CFL LED , ARRAY JUNCTION BOX FOR CONNECTING 250W X 4 NOS. SOLAR PANEL , ELECTRICAL WIRING AND SWITCH GEAR RACK , DISCRETE COMPONENT TRAINER , PROTECTIVE RELAYS AND CONTACTORS RACK
Advisory Bank
State Bank of India
ePBG Percentage
5%
ePBG Duration (Months)
12
Payment Timelines
Payments shall be made to the Seller within 45 days of issue of consignee receipt-cum-acceptance certificate (CRAC) and on-line submission of bills (This is in supersession of 10 days time as provided in clause 12 of GeM GTC)
Pre-Bid Date
13-10-2026 14:00:00
Pre-Bid Venue
ITI BHANVAD, TRAN PATIYA ROAD, NEAR MARKETING YARD, BHANVAD, TA- BHANVAD, DI-DEVBHUMI DWARKA-360510
Max Delivery Days
15
Delivery Locations
1
Delivery Cities
Devbhumi Dwarka
Delivery Pincodes
360510
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| Nareshkumar B Kathrotiya | 360510,GOVT. INDUSTRIAL TRAINING INSTITUTE, BHANVAD, BHANVAD TRAN PATIYA ROAD, TA- BHANVAD, DI - DEVBHUMI DWARKA | Devbhumi Dwarka | Gujarat | 360510 | 1 | 15 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
FREQUENCY METER DIGITAL
Frequency Meter Digital suitable for armature motor rewinding and electrical testing laboratories. Measuring range 20 Hz to 99.9 Hz. Suitable for standard 50 Hz and 60 Hz AC power supply. High brightness 3 digit or 4 digit red LED display. Operating voltage 110 V to 230 V AC at 50 Hz. Accuracy 0.1 Hz. Display resolution 0.01 Hz or 0.1 Hz. Panel mounting type. Panel cutout size 96 mm x 96 mm or 48 mm x 96 mm. Durable ABS plastic or polycarbonate enclosure.
ELECTRICAL LOAD SET OF INCANDESCENT LAMP TUBE LIGHT CFL LED
Electric load Set of Incandescent lamp 100 watt 10 pieces, Tube light-40 watt 10 pieces, CFL-10 watt 10 pieces, LED light 9 watt 10pieces
ARRAY JUNCTION BOX FOR CONNECTING 250W X 4 NOS. SOLAR PANEL
WITH DC FUSE, DC MCB, AND SURGE SUPPRESSOR PROTECTION
ELECTRICAL WIRING AND SWITCH GEAR RACK
The setup shall consist of electrical control elements suitable for practicing control circuits using banana plugs and sockets for easy and safe connections. The panel board shall be fabricated using a sturdy 40 mm x 40 mm aluminum conveyor frame, incorporating a main input panel with provisions for connecting two bulbs, tube light, AC fan, digital ammeter, voltmeter, energy meter, intermediate switch & house bell wiring. The assembly shall be mounted on a mild steel table, topped with 18 mm ply glossy finished with a durable laminate surface & all 4 sides shall be fitted with a PVC edge band for added protection and an aesthetically clean finish.
DISCRETE COMPONENT TRAINER
TECHNICAL SPECIFICATIONS Fixed DC Power Supply IC Regulated +5V DC and +/-12V DC 250mA. Variable DC Power Supply IC Regulated 0-5V DC and 0-12V DC 250mA. AC Power Supply 15-0-15V AC 250mA. Operated on mains power 230V 50Hz plus or minus 10 percent. Variable Resistors 1K 10K and 100K provided on board. 3 pairs of connected 2mm sockets. Rectifier Diodes 4 Nos Diode 4007. OA79 Germanium Diode. Zener Diodes 3 Nos of 5.1V 8.2V and 12V. Different values of resistances capacitors and inductors including 2 Nos of 10mH. DIAC DB33. SCR 2P4M. TRIAC BT136. MOSFET IRF540. UJT 2N2646. JFET 2N4393. SL100 and SK100 pair. LDR. Thermistor. Buzzer 1 each and LEDs 2 Nos Red and Green. 1 Buzzer. SALIENT FEATURES Front panel built with high class insulated printed circuit board sheet with well printed circuits and symbols. Instruction Manual. Connections brought out through 2mm Brass Sockets. Patch Cords 2mm. Trainer housed in ABS Plastic cabinet. Size of trainer set 12 inch x 8 inch. STANDARD ACCESSORIES User Manual. Patchcords. LIST OF EXPERIMENTS 1 PN Junction Diode V-I Characteristics. 2 Zener Diode V-I Characteristics. 3 Voltage Stabilization of Zener Diode. 4 LED Characteristics. 5 Resistance in Series and Parallel. 6 Charging and Discharging of Condenser. 7 LCR Resonance Circuit. 8 Clipping and Clamping. 9 Half Wave Full Wave and Bridge Rectifier. 10 Common Base Transistor Amplifier. 11 Common Emitter Transistor Amplifier. 12 Common Collector Transistor Amplifier. 13 RC Coupled Amplifier. 14 Basic Logic Gates. 15 RC Passive Filter Circuits and many more.
PROTECTIVE RELAYS AND CONTACTORS RACK
The setup shall be suitable for practicing control circuits using banana plugs and sockets. It shall include Protector Relays operating at a working voltage of 230V AC, with under-voltage settings between 160-220V, over-voltage settings between 230-300V, and a fixed time setting of 2.5 seconds. The panel shall be constructed using a 40 mm x 40 mm aluminum conveyor frame and shall feature a main input panel equipped with a push-button station, an under and over voltage protection relay and a contactor station, with all terminals brought out for trainees to practice wiring exercises. The entire assembly shall be mounted on a mild steel table, topped with 18 mm thick plywood, finished with a durable laminate surface and edged on all four sides with PVC edge banding for protection and a clean appearance.
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) | Price Trends |
|---|---|---|---|---|---|---|---|
| 1 | FREQUENCY METER DIGITAL | Frequency Meter Digital suitable for armature motor rewinding and electrical testing laboratories. Measuring range 20 Hz to 99.9 Hz. Suitable for standard 50 Hz and 60 Hz AC power supply. High brightness 3 digit or 4 digit red LED display. Operating voltage 110 V to 230 V AC at 50 Hz. Accuracy 0.1 Hz. Display resolution 0.01 Hz or 0.1 Hz. Panel mounting type. Panel cutout size 96 mm x 96 mm or 48 mm x 96 mm. Durable ABS plastic or polycarbonate enclosure. | 1 | nos | bhanvad_con | 15 | |
| 2 | ELECTRICAL LOAD SET OF INCANDESCENT LAMP TUBE LIGHT CFL LED | Electric load Set of Incandescent lamp 100 watt 10 pieces, Tube light-40 watt 10 pieces, CFL-10 watt 10 pieces, LED light 9 watt 10pieces | 2 | nos | bhanvad_con | 15 | |
| 3 | ARRAY JUNCTION BOX FOR CONNECTING 250W X 4 NOS. SOLAR PANEL | WITH DC FUSE, DC MCB, AND SURGE SUPPRESSOR PROTECTION | 2 | nos | bhanvad_con | 15 | |
| 4 | ELECTRICAL WIRING AND SWITCH GEAR RACK | The setup shall consist of electrical control elements suitable for practicing control circuits using banana plugs and sockets for easy and safe connections. The panel board shall be fabricated using a sturdy 40 mm x 40 mm aluminum conveyor frame, incorporating a main input panel with provisions for connecting two bulbs, tube light, AC fan, digital ammeter, voltmeter, energy meter, intermediate switch & house bell wiring. The assembly shall be mounted on a mild steel table, topped with 18 mm ply glossy finished with a durable laminate surface & all 4 sides shall be fitted with a PVC edge band for added protection and an aesthetically clean finish. | 1 | nos | bhanvad_con | 15 | |
| 5 | DISCRETE COMPONENT TRAINER | TECHNICAL SPECIFICATIONS Fixed DC Power Supply IC Regulated +5V DC and +/-12V DC 250mA. Variable DC Power Supply IC Regulated 0-5V DC and 0-12V DC 250mA. AC Power Supply 15-0-15V AC 250mA. Operated on mains power 230V 50Hz plus or minus 10 percent. Variable Resistors 1K 10K and 100K provided on board. 3 pairs of connected 2mm sockets. Rectifier Diodes 4 Nos Diode 4007. OA79 Germanium Diode. Zener Diodes 3 Nos of 5.1V 8.2V and 12V. Different values of resistances capacitors and inductors including 2 Nos of 10mH. DIAC DB33. SCR 2P4M. TRIAC BT136. MOSFET IRF540. UJT 2N2646. JFET 2N4393. SL100 and SK100 pair. LDR. Thermistor. Buzzer 1 each and LEDs 2 Nos Red and Green. 1 Buzzer. SALIENT FEATURES Front panel built with high class insulated printed circuit board sheet with well printed circuits and symbols. Instruction Manual. Connections brought out through 2mm Brass Sockets. Patch Cords 2mm. Trainer housed in ABS Plastic cabinet. Size of trainer set 12 inch x 8 inch. STANDARD ACCESSORIES User Manual. Patchcords. LIST OF EXPERIMENTS 1 PN Junction Diode V-I Characteristics. 2 Zener Diode V-I Characteristics. 3 Voltage Stabilization of Zener Diode. 4 LED Characteristics. 5 Resistance in Series and Parallel. 6 Charging and Discharging of Condenser. 7 LCR Resonance Circuit. 8 Clipping and Clamping. 9 Half Wave Full Wave and Bridge Rectifier. 10 Common Base Transistor Amplifier. 11 Common Emitter Transistor Amplifier. 12 Common Collector Transistor Amplifier. 13 RC Coupled Amplifier. 14 Basic Logic Gates. 15 RC Passive Filter Circuits and many more. | 1 | nos | bhanvad_con | 15 | |
| 6 | PROTECTIVE RELAYS AND CONTACTORS RACK | The setup shall be suitable for practicing control circuits using banana plugs and sockets. It shall include Protector Relays operating at a working voltage of 230V AC, with under-voltage settings between 160-220V, over-voltage settings between 230-300V, and a fixed time setting of 2.5 seconds. The panel shall be constructed using a 40 mm x 40 mm aluminum conveyor frame and shall feature a main input panel equipped with a push-button station, an under and over voltage protection relay and a contactor station, with all terminals brought out for trainees to practice wiring exercises. The entire assembly shall be mounted on a mild steel table, topped with 18 mm thick plywood, finished with a durable laminate surface and edged on all four sides with PVC edge banding for protection and a clean appearance. | 1 | nos | bhanvad_con | 15 |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Additional Doc 1 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer