Non Refrigerated Centrifuge for General Purpose and research
Central Railway
Bid Publish Date
30-Jun-2026, 10:30 am
Bid End Date
21-Jul-2026, 11:00 am
Location
Progress
Quantity
2
Bid Type
Two Packet Bid
A tender has been published for Employees State Insurance Corporation Non Refrigerated Centrifuge for General Purpose and research (Q3) in COIMBATORE, TAMIL NADU. Quantity: 2 by. Submission Deadline: 21-07-2026 11: 00: 00. Check eligibility and apply.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
Non Refrigerated Centrifuge for General Purpose and research (Q3)
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
GEM_GENERAL_TERMS_AND_CONDITIONS
Central Railway
N/a
N/a
PUNE, MAHARASHTRA
N/a
GAUTAM BUDDHA NAGAR, UTTAR PRADESH
Directorate Of Purchase And Stores
HYDERABAD, TELANGANA
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| Standards | Conformity to standards | IEC 61010-1 |
| Performance Parameters | Purpose | To Centrifuge different kinds of samples in different Labs and research Labs at room Temperature |
| Performance Parameters | Centrifuge design | Bench Top |
| Performance Parameters | Weight including Rotor in kgs | 36 |
| Performance Parameters | Maximum RPM with no load | 20000, < 20000 |
| Performance Parameters | "Number of steps of RPM Variation available in the settings (correspondingly RCF also varies) " | 10 |
| Performance Parameters | RPM setting accuracy | plus minus 5% |
| Performance Parameters | Type of Motor | Brushless(without carbons) |
| Performance Parameters | Type of lid lock | Both Manual and Electronic |
| Performance Parameters | Maximum Noise level when working at 1 meter distance in db | 56 |
| Performance Parameters | Ambient operating Temperature range in Degree centigrade Celsius and Humidity Range | 0 to 40 and relative humidity is 15 to 80% |
| Performance Parameters | Rotor imbalance diagnostics and automatic stop if required | Yes |
| Performance Parameters | No of accelaration and decelarion profiles in built for rotor speed while automatic braking | "Programmable from 50 to 200 Seconds in Interval of 5 Seconds" |
| Performance Parameters | Maximum timer set point | 60 minutes |
| Performance Parameters | Configuration of Rotor supplied with centrifuge machine | Swing Out |
| Performance Parameters | Rotor Feature With Reference to Autoclavability | Autoclavable Rotor @121 Degree Celsus |
| Performance Parameters | Type of Tubes which can be used with centrifuge machine | Polypropylene Centrifuge tubes and Glass centrifuge tubes |
| Performance Parameters | Size of rotor supplied with centrifuge | 24x15ml(For swing out type rotor RPM 5000) |
| Performance Parameters | Maximum RCF | 5250 |
| Performance Parameters | Power supply | 230 Volts 50 Hz AC ± 10% |
| Performance Parameters | Power consumption in watts | 370 |
| Performance Parameters | Accessories | Spanner to tight or loose Nut of Rotor on Motor shaft head puller,spare rotor nuts ,fuse-2, Instruction Manual Book ,installation CD, Power supply cable, Instruction Manual |
| Performance Parameters | Warranty period in years | 1 |
| Material Parameters | Assembly Material for manufacture of Centrifuge | Steel armor plate with high-impact PC-ABS plastic cover |
| Material Parameters | "Lid Material of Centrifuge " | CRC Steel finish with powder coating or stove painting or ABS Plastic of injection moulding |
| Material Parameters | Body material of Centrifuge | C.R.C Steel Finish with Powder Coating/ Stove Painting |
| Material Parameters | Front Panel of centrifuge | high-impact PC-ABS plastic |
| Material Parameters | Centrifuge Bowl material in Centrifuge | 304 Quality Stainless Steel Moulded |
| Additional Parameters | The Equipment shall be installed and demonstrated before Acceptance | Yes |
| Additional Parameters | Servo Controller Voltage Stabilizer supplied with Item | No |
| Additional Parameters | Servo stabilizer ratings in KVA | Not Supplied |
| Additional Parameters | Warranty of stabilizer in years | Not supplied |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Employees State Insurance Corporation
📍 PATNA, BIHAR
N/a
📍 KRISHNA, ANDHRA PRADESH
N/a
📍 CENTRAL DELHI, DELHI
Navsari Agricultural University Navsari
📍 NAVSARI, GUJARAT
All India Institute Of Medical Sciences (aiims)
📍 JODHPUR, RAJASTHAN
Sign up now to access all documents
Main Document
CATALOG Specification
GEM_GENERAL_TERMS_AND_CONDITIONS