1

Bid Type

Two Packet Bid

Categories 6

Public procurement opportunity for Indian Council Of Agricultural Research (icar) Gas Chromatography (Q3). Quantity: 1 issued by. Submission Deadline: 27-07-2026 16: 00: 00. View full details and respond.

Additional Tender Data

Commercial Details

Tender Category

Goods

Bid To RA

No

Bid To RA Enabled

Yes

Item Category

Gas Chromatography (Q3)

Advisory Bank

State Bank of India

ePBG Percentage

5%

ePBG Duration (Months)

14

Pre-Bid & Qualification

Pre-Bid Date

21-07-2026 11:00:00

Pre-Bid Venue

Committee Room, ICAR-CIRB, Sirsa Road, Hisar

Delivery Details

Max Delivery Days

60

Delivery Locations

1

Delivery Cities

Hisar

Delivery Pincodes

125001

Delivery Locations

ConsigneeAddressCityStatePincodeQuantityDelivery DaysAdditional Requirement
Ashok Kumar125001,ICAR - CENTRAL INSTITUTE FOR RESEARCH ON BUFFALOES, HISARHisarHaryana125001160-

Authority Records

MINISTRY OF AGRICULTURE AND FARMERS WELFAREAGRICULTURAL RESEARCH AND EDUCATION DEPARTMENT

BID & GeM Expert Consultancy

End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.

Bid Preparation GeM Registration Document Filing

Free consultation · 24h response

Documents 4

GeM-Bidding-9617590.pdf

Main Document

CATALOG-Specification-1

CATALOG Specification

Other Documents

OTHER

GEM General Terms and Conditions Document

GEM_GENERAL_TERMS_AND_CONDITIONS

Past Similar Tenders (Historical Results)

5 found

Gas Chromatography

Mahatma Phule Krishi College Of Agriculture Pune

AHMEDNAGAR, MAHARASHTRA

Posted: 12 February 2026
Closed: 26 February 2026
GEM

Gas Chromatography

Brahmaputra Valley Fertilizer Corporation Limited (bvfcl)

DIBRUGARH, ASSAM

Posted: 27 May 2025
Closed: 4 July 2025
GEM

Gas Chromatography

Agharkar Research Institute (ari)

PUNE, MAHARASHTRA

Posted: 17 January 2025
Closed: 10 February 2025
GEM

CSIR Gas Chromatography Equipment Tender Jorhat Assam 2025

Council Of Scientific And Industrial Research (csir)

JORHAT, ASSAM

Posted: 28 November 2025
Closed: 28 January 2026
GEM

Agriculture Department Uttarakhand Gas Chromatograph Procurement Udham Singh Nagar 2026 IS/IEC 61010-1 EMI 61326-1

N/a

UDHAM SINGH NAGAR, UTTARAKHAND

Posted: 27 February 2026
Closed: 9 March 2026
GEM

Technical Specifications 1 Item

Item #1 Details

View Catalog
Category Specification Requirement
GAS CHROMATOGRAPH (GC) CONFIGURATION "GC Detectors inclusive in the scope of supply (Select Only those Detectors, which are part of supply)" Flame Ionization Detector (FID), Thermal Conductivity Detector (TCD or Hot Wire Detector), Electron Capture Detector (ECD), Nitrogen–Phosphorus Detector (NPD) / Flame Thermionic Detector (FTD), Flame Photometric Detector (FPD), Photo Ionization Detector (PID), Pulsed Flame Photometric Detector (PFPD)
GAS CHROMATOGRAPH (GC) CONFIGURATION "Number of FID in the System - inclusive in the scope of Supply (Select '0' if this Detector is not a part of supply)" 0, 1, 2
GAS CHROMATOGRAPH (GC) CONFIGURATION "Number of TCD in the System - inclusive in the scope of Supply (Select '0' if this Detector is not a part of supply)" 0, 1, 2
GAS CHROMATOGRAPH (GC) CONFIGURATION "Number of ECD in the System - inclusive in the scope of Supply (Select '0' if this Detector is not a part of supply)" 0, 1, 2
GAS CHROMATOGRAPH (GC) CONFIGURATION "Number of NPD/FTD in the System - inclusive in the scope of Supply (Select '0' if this Detector is not a part of supply)" 0, 1, 2
GAS CHROMATOGRAPH (GC) CONFIGURATION "Number of FPD in the System - inclusive in the scope of Supply (Select '0' if this Detector is not a part of supply)" 0, 1, 2
GAS CHROMATOGRAPH (GC) CONFIGURATION "Number of PID in the System - inclusive in the scope of Supply (Select '0' if this Detector is not a part of supply)" 0, 1, 2
GAS CHROMATOGRAPH (GC) CONFIGURATION "Number of PFPD in the System - inclusive in the scope of Supply (Select '0' if this Detector is not a part of supply)" 0, 1, 2
GAS CHROMATOGRAPH (GC) CONFIGURATION Number of Inlets GC can Simultaneously Support 1, 2, 3
GAS CHROMATOGRAPH (GC) CONFIGURATION Number of Detectors (Ports) GC can Simultaneously Support 1, 2, 3, 4
GAS CHROMATOGRAPH (GC) CONFIGURATION Number of Capillary Columns provided in GC - inclusive in the scope of Supply 0, 1, 2
GAS CHROMATOGRAPH (GC) CONFIGURATION Type of Capillary Column Polar, Non-Polar, Semi-Polar, NA
GAS CHROMATOGRAPH (GC) CONFIGURATION "GC Capillary Column Length (Hint:-Select '0' if Not Applicable)" 0, 30, 60, 100
GAS CHROMATOGRAPH (GC) CONFIGURATION "Number of Packed Columns provided in GC - inclusive in the scope of Supply (Hint:-Select '0' if Not Applicable)" 0, 1, 2
GAS CHROMATOGRAPH (GC) CONFIGURATION "GC Packed Column Length (Hint:-Select '0' if Not Applicable)" 0, 3, 6, 9, 12
PERFORMANCE "GC Detector Minimum Detection Level (MDL) " < 1.4 pg C/s for FID, < 1.8 pg C/s for FID, < 3.0 pg C/s for FID < 400 pg/ml for TCD, < = 1 microgram/ml for TCD, < = 10 microgram/ml for TCD, < 4.5 fg /sec for ECD, < 5.5 fg /sec for ECD, <= 100 fg/sec for ECD, < 0.1pg N /sec for NPD/FTD, < 0.03 pg P /sec for NPD/FTD, <0.5 pg P/s for NPD/FTD, < 45 fg P /sec for FPD, < 100 fg P /sec for FPD, <2.5 pg S /sec for FPD, <2.5 pg S /sec for FPD, <5 pg S /sec for FPD, <10pg S/s for FPD
COLUMN OVEN (GAS CHROMATOGRAPH - GC) Maximum Operating Temperature (GC Oven) upto 400 deg. C, upto 450 deg. C (2) Or higher
COLUMN OVEN (GAS CHROMATOGRAPH - GC) Number of Oven Ramps / Plateaus for Temperature programming 6/7 or more, 9/10 or more, 20/21 or more
COLUMN OVEN (GAS CHROMATOGRAPH - GC) Temperature Ramp Rate - Maximum 120 Deg. C/minute or better, 50 Deg. C/minute or better
PNEUMATIC CONTROL Number of Injection Ports 1, 2
PNEUMATIC CONTROL Maximum Injection Port heating Temperature upto 400 deg. C (1), upto 450 deg. C (2) Or higher
PNEUMATIC CONTROL Pressure Range upto100 psi (1), upto 120 psi (2) Or higher
PNEUMATIC CONTROL Pressure set point Resolution (±)(psi) 0.001, 0.01, 0.1 Or lower
PNEUMATIC CONTROL Type of Sample Injection Port Split, Splitless, split / Splitless, Purged packed Inlet
PNEUMATIC CONTROL Split Ratio 6000:1, 7000:1, 7500:1, NA
AUTO INJECTOR / AUTO SAMPLER Compatible Liquid Auto Sampler - inclusive in the scope of supply Yes, No
AUTO INJECTOR / AUTO SAMPLER Capacity of the Liquid Auto Sampler (Number of Vials) 0, 15, 100, 150 Or higher
AUTO INJECTOR / AUTO SAMPLER Number of Injection Ports in the Liquid Auto Sampler 0, 1, 2
AUTO INJECTOR / AUTO SAMPLER Number of Channels in the Liquid Auto Sampler 0, 2
AUTO INJECTOR / AUTO SAMPLER Minimum Volume of the injected liquid sample 0 - 1
AUTO INJECTOR / AUTO SAMPLER Maximum Volume of the injected liquid sample 0 - 100
AUTO INJECTOR / AUTO SAMPLER "Liquid Auto Sampler Features (Select applicable features Only)" Fully automated Liquid Auto Sampler, Injects with variable speed & varying syringe sizes, Operates through Software (Software inclusive in the scope of supply), NA
HEAD SPACE SAMPLER Compatible Head Space Sampler- inclusive in the scope of supply Yes, No
HEAD SPACE SAMPLER Capacity of the Head Space Sampler Carousel (number of Vials) 12 or better, NA
HEAD SPACE SAMPLER Head Space Sampler Temperature Range Upto 200 deg. C or better, NA
PYROLYZER SYSTEM Compatible Pyrolyzer System for pyrolysis of solid and liquid samples- inclusive in the scope of supply Yes, No
SALIENT FEATURES OF GAS CHROMATOGRAPH (GC) "Salient Featutes of GC (Select applicable features Only)" Automatic leak testing/detection of Pneumatics, Direct setting of split flow rates and ratios, Flow sensor for control & storage of split ratio, Split and Septum Purge gases, Able to direct inject onto packed and wide-bore capillary columns, Oven power turns-off automatically when the lid/door is opened, Over Heat Protection, Display Unit with built-in Key Board, Controlled by External PC System, NA
SOFTWARE "Software Features (Select Applicable Features only)" Compatible with Windows 7 or higher version operating system, Seamless integration & control of all the GC parameters, Interface with Multiple GCs through the comprehensive real-time monitoring and diagnostic software, Real time notification via advisories and indicators, Counters, Chromatographic attributes, Instrument diagnostics, Access to maintenance information, Access to maintenance, run and event logs, Retention Time - Locking module for analyzing target compounds in complex matrices
GENERIC Display Through PC (PC is not part of supply), Built-in Display
GENERIC Connectivity interface USB, WIFI, ETHERNET, Bluetooth, RS 232, RJ-45
GENERIC Provision to split the sample from single injection to two different detectors and get results for two detectors simultaneously Yes, No
ACESSORIES Gas Supply inclusive in the scope of supply Nitrogen, Hydrogen, Argon, Helium, Zero Air, Not offered
ACESSORIES Capacity of Gas cylinder 47 liters water capacity, Not offered
ACESSORIES Number of Cyliners of each type supplied - inclusive in the scope of supply 0, 1, 2
ACESSORIES Gas cylinders certified by PESO Yes, No for Gas Cylinder Not Offered
ACESSORIES Regulator - inclusive in the scope of supply Dual Stage Regulator, NA
ACESSORIES "Other Accessories inclusive in the scope of supply (Select only those Accessories which are part of supply)" Gas purification panel for all Gases with moisture trap, Hydrocarbon trap & Oxygen trap, Syringe for manual injection x 05 nos, Auto Sampler Vials x 1000 vials with screw cap, Graphite ferrules x 10 nos, Vessel ferrules x 10 nos, Septa for injector x 100 nos, Inlet liner for splitles x 4 nos, Inlet liner for split x 4 nos, O-rings x 10 nos. of each type, Column Cutter x 2 nos, Gas tube Cutter x 2 nos, Tool Kit x 1 no., User / Technical / Maintenance Manual, Standard Samples - NIST / IPL Traceable, NA
ENVIRONMENTAL Minimum Operating Temperature 0 - 10
ENVIRONMENTAL Maximum Operating Temperature 30 - 65
ENVIRONMENTAL Operating Humidity (RH) (%) at 40 degree C Up to 95
INSTALLATION & COMMISSIONING / WARRANTY / AVAILABILITY OF SPARES / TRAINING Warranty on equipment 1.0
INSTALLATION & COMMISSIONING / WARRANTY / AVAILABILITY OF SPARES / TRAINING Number of days onsite training provided 3, 5, 7, 10
CERTIFICATION / TEST REPORT "Availability of UL/CE Certificate as per IEC 61010- 1 latest - Safety requirements for electrical equipment for measurement,control, and laboratory use General requirements" Yes, No
CERTIFICATION / TEST REPORT Conformance to EMC/EMI as per IEC 61326-1 latest - Electrical equipment for measurement, control and laboratory use Yes, No
CERTIFICATION / TEST REPORT Availability of Test Reports from Central Govt / NABL approved / ILAC accredited Lab to prove conformity to the specification Yes, No

🤖 AI-Powered Bidder Prediction

Discover companies most likely to bid on this tender

Live AI
Historical Data

Required Documents

1

Experience Criteria

2

Bidder Turnover

3

Certificate (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria

4

the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer

Similar Tenders

5 found

Gas Chromatography

Telangana State Dairy Development Cooperative Fed

📍 HYDERABAD, TELANGANA

EMD: ₹32,000
⏰ Deadline: 2 weeks left
🛒 Type: Goods
View GEM

ICAR Gas Chromatograph Configuration Tender India 2026 IS 61010-1/EMD ₹150000

Indian Council Of Agricultural Research (icar)

EMD: ₹1.5 L
⏰ Deadline: 2 weeks left
🛒 Type: Goods
View GEM
Urgent

Gas Chromatography Syringe

Power Grid Corporation Of India Limited

📍 BIDAR, KARNATAKA

⏰ Deadline: 4 days left
🛒 Type: Goods
View GEM
Urgent

Gas Chromatography Syringe

Power Grid Corporation Of India Limited

📍 GURGAON, HARYANA

⏰ Deadline: 6 days left
🛒 Type: Goods
View GEM

Gas Chromatography Mass Spectrometry (GC - MS)

N/a

📍 SOUTH ANDAMAN, ANDAMAN & NICOBAR

EMD: ₹2.2 L
Est: ₹1.1 Cr
⏰ Deadline: 2 weeks left
🛒 Type: Goods
View GEM