Isolation Transformer
Indian Coast Guard
Bid Publish Date
27-Feb-2026, 3:15 pm
Bid End Date
20-Mar-2026, 3:00 pm
EMD
₹12,540
Location
Progress
Quantity
43
Category
Isolation Transformer
Bid Type
Two Packet Bid
N/a invites bids for Isolation Transformer (Q2) in RAIPUR, CHHATTISGARH. Quantity: 43. Submission Deadline: 20-03-2026 15: 00: 00. Submit your proposal before the deadline.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
Isolation Transformer (Q2)
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Indian Coast Guard
Indian Space Research Organization
THIRUVANANTHAPURAM, KERALA
Indian Air Force
WEST DELHI, DELHI
Rail Wheel Plant Bela
SARAN, BIHAR
Indian Air Force
CHANDIGARH, CHANDIGARH
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| CONSTRUCTION | Isolation transformer suitable for installed at | Inside the Lighting Distribution Board (LDB), at Welding DB panel itself, By the side of respective LDB, By the side of respective Welding DB, Inside Neutral Grounding Cubicle |
| GENERIC | Description of store | Isolation transformer for lighting, Dry type, Isolation transformer for Neutral Grounding |
| GENERIC | Rating (in KVA) | 100, 20, 10, 30, 50 |
| GENERIC | No. of phase (in Nos.) | 1 |
| GENERIC | Winding connection HV/LV | Delta/Star, Not applicable for Isolation transformer for Neutral Grounding |
| GENERIC | Voltage ratio | 415/415V, +/- 5% taps (OCTC) in steps of 2.5%, 11000V/110V |
| GENERIC | Insulation class | B, F |
| GENERIC | One minute power frequency withstand voltage (in KV) | 2.5, 35 |
| GENERIC | Material of enclosure | CR sheet (2.0 mm thick), Not applicable for Isolation transformer for Neutral Grounding |
| GENERIC | Enclosure protection (IP Rating), Ref. IS/IEC:60947 latest | IP 42, Not applicable for Isolation transformer for Neutral Grounding |
| GENERIC | Enclosure protection transformer terminal box (IP Rating), Ref. IS/IEC:60947 latest | IP 52, Not applicable for Isolation transformer for Neutral Grounding |
| FITTINGS FOR EACH TRANSFORMER | Number of Termination insulators (hint: If not applicable select "0") | 0, 1, 2, 3, 4, 5 |
| FITTINGS FOR EACH TRANSFORMER | Number of Winding temperature indicator (s) with alarm and trip contact (as applicable) (hint: If not applicable selet "0") | 0, 1, 2, 3, 4, 5 |
| FITTINGS FOR EACH TRANSFORMER | Number of Cover lifting eyes (hint: If not applicable select "0") | 0, 1, 2, 3, 4, 5 |
| FITTINGS FOR EACH TRANSFORMER | Number of Transformer lifting lugs (hint: If not applicable select "0") | 0, 1, 2, 3, 4, 5 |
| FITTINGS FOR EACH TRANSFORMER | Number of Core and winding lifting lugs (hint: If not applicable select "0") | 0, 1, 2, 3, 4, 5 |
| FITTINGS FOR EACH TRANSFORMER | Number of Earthing terminals (hint: If not applicable select "0") | 0, 1, 2, 3, 4, 5 |
| FITTINGS FOR EACH TRANSFORMER | Number of Cable boxes (hint: If not applicable write "0") | 0, 1, 2, 3, 4, 5 |
| FITTINGS FOR EACH TRANSFORMER | Number of Tap changing links | Off Circuit 1 No., Not applicable |
| FITTINGS FOR EACH TRANSFORMER | Other requirements for each transformer | Supporting structure, Foundation Bolts, Rating and diagram plate, Towing holes |
| TESTS | Agreed to furnish additional routine test reports for | Insulation resistance, Iron loss, Paint shade, thickness/adhesion, Enclosure sheet thickness, Not applicable |
| TESTS | Agreed to furnish special test reports to buyer /consignee on demand | Partial discharge measurement, Measurement of acoustic sound level, Short-circuit test, IP protection for Cable box and Enclosure, Not applicable |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Additional Doc 1 (Requested in ATC)
Additional Doc 2 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Institute For Plasma Research
Bharat Dynamics Limited
📍 MEDAK, TELANGANA
Indian Space Research Organization
📍 THIRUVANANTHAPURAM, KERALA
The Fertilisers And Chemicals Travancore Limited
📍 ERNAKULAM, KERALA
Prasar Bharati Broadcasting Corporation Of India
Sign up now to access all documents
Main Document
CATALOG Specification
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS