TenderDekho Logo
GEM

Procurement Opportunity: Power Generator - DG Set (up to 900 KVA),Power Generator - DG Set (up to 900 KVA) in SRINAGAR, JAMMU & KASHMIR

Bid Publish Date

23-Jan-2026, 11:45 am

Bid End Date

13-Feb-2026, 12:00 pm

EMD

₹35,670

Value

₹17,83,500

Progress

Issue23-Jan-2026, 11:45 am
AwardPending
Explore all 4 tabs to view complete tender details

Quantity

2

Category

Power Generator - DG Set (up to 900 KVA)

Bid Type

Two Packet Bid

Indo Tibetan Border Police (itbp) has released a public tender for Power Generator - DG Set (up to 900 KVA) (Q2) in SRINAGAR, JAMMU & KASHMIR. Quantity: 2. Submission Deadline: 13-02-2026 12: 00: 00. Download documents and apply online.

Documents 5

GeM-Bidding-8863195.pdf

Main Document

CATALOG-Specification-1

CATALOG Specification

CATALOG-Specification-2

CATALOG Specification

Other Documents

OTHER

GEM General Terms and Conditions Document

GEM_GENERAL_TERMS_AND_CONDITIONS

Past Similar Tenders (Historical Results)

5 found

Indian Army Gen Set Honda 2.3KVA Repair & Overhaul Tender Poonch Jammu & Kashmir 2026

Indian Army

POONCH, JAMMU & KASHMIR

Posted: 14 January 2026
Closed: 24 January 2026
GEM

Indian Army Repair of GenSet 3.5 KVA PERFECT D69 5000 Overhauling Tender PoONCH Jammu & Kashmir 2026

Indian Army

POONCH, JAMMU & KASHMIR

Posted: 14 January 2026
Closed: 24 January 2026
GEM

Indian Army PUMP ELEMENT 15 KVA PCU & related cards Tender Srinagar Jammu & Kashmir 2026

Indian Army

SRINAGAR, JAMMU & KASHMIR

Posted: 14 January 2026
Closed: 24 January 2026
GEM

3 5 KVA Generator Armature Faulty,3 5 KVA Generator Fuel Pump not Work,3 5 KVA Generator Engine Hea

Indian Army

RAJAURI, JAMMU & KASHMIR

Posted: 13 January 2026
Closed: 23 January 2026
GEM

Stage set up and banner,Sound arrangement,First Prize,Second Prize,Participants Prize,Refreshment f

Indian Army

RAJAURI, JAMMU & KASHMIR

Posted: 13 January 2026
Closed: 23 January 2026
GEM

Technical Specifications 2 Items

Item #1 Details

View Catalog
Category Specification Requirement
Power Generator INSTALLATION CONFIGURATIONS Power Generator installation configurations as defined in CPWD General Specifications for Electrical works - Part VII (DG Set) Fixed (Power Generators are permanently installed)"
OUTPUT CAPACITY RATING/ PHASE Nominal Rated Capacity (kVA) 125
OUTPUT CAPACITY RATING/ PHASE No of Phase (Single Phase-3-5kVA) (Single Phase or Three Phase-5 & 7-5, 10,15, 20, 25, 30 & 40 kVA) (Three Phase-50 to 900 kVA) Three Phase
ENGINE Rated Engine Power (kWm) 100 % of the required powered at STP(Standard Temperature Pressure) i.e equal to (Nominal Rated Capacity (KVA) of power generator + Any Auxilary power Consumption by the Power generator) x Power factor(0.8) / Alternator efficience, 110 % of the required powered at STP(Standard Temperature Pressure) i.e equal to (Nominal Rated Capacity (KVA) of power generator Any Auxilary power Consumption by the Power generator) x Power factor(0.8) / Alternator efficience Or higher
ENGINE Type of Engine cooling Liquid Cooled
ENGINE Type of governer Electronic Or higher
ENGINE Number of cylinders (nos) 4
ENGINE Rated RPM of Engine (RPM) 1500
ENGINE Fuel High Speed Diesel (HSD)
ALTERNATOR Voltage Regulation Grade VG 3 Or higher
ALTERNATOR Alternator IP Rating IP 23 Or higher
CONTROL PANEL Control Panel AMF Control Panel
CONTROL PANEL Control Panel Location Outside the Canopy
CONTROL PANEL IP Rating of Control Panel IP 53, IP 54, IP 55 Or higher
ACOUSTIC ENCLOSURE Noise level at 1 meter (dB) 75
Fuel Tank Fuel Tank Features Fuel Tank capacity is sufficient for 8 hrs of running at full load
TRAILER Trailer Yes
TRAILER Pay load of the Trailer 0, 500, 1000, 2000 Or higher
SCOPE OF INSTALLATION Installation with installation - inclusive in the scope of supply Or higher
SCOPE OF INSTALLATION Scope of installation for Diesel Generating Set when offered by the vendor - inclusive in the scope of supply(Part-1) a) Installation of Power Generator when offered by the vendor is inclusive in the scope of supply and shall be done by the seller. The installation work of Power Generator and its constituent parts shall be generally conforming to CPWD General Specification for Electrical Works, Part - VII - latest. b) Foundation shall be constructed by the seller. Foundation shall be of PCC type with the ratio of 4:2:1. The length and breadth of the foundation shall be 300 mm more from the respective length and breadth of the Power Generator. The height of the foundation shall be 400 mm, i.e., 200 mm below and 200 mm above the ground level. All the materials / labour required for foundation work shall be supplied by the seller.
SCOPE OF INSTALLATION Scope of installation for Diesel Generating Set when offered by the vendor - inclusive in the scope of supply(Part-2) c) Supply, laying and termination of interconnecting power and control cable shall be done by the seller. The cable supplied shall be ISI marked heavy duty PVC insulated, armoured cable, with PVC outer Sheath of Type ST-2 (FR Grade, Category C1), with aluminium conductor having insulation of PVC compound type -C, suitable for rated voltage upto and including 1100 volts and conforming to IS: 1554 (Part-1) latest. For 3-Phase Power Generators, 3.5 core or higher core cables shall be used. Total length of the cable supplied by the seller shall be within 30 meters for each Power Generator with manual control panel and within 60 metres for each Power Generator with AMF control panel. The current rating of the cables shall be as indicated below: 2C, 6 Sq mm for Single Phase, 3.5 & 5.0 KVA 2C, 10 Sq mm for Single Phase, 7.5 & 10 KVA 2C, 25 Sq mm for Single Phase, 15 KVA 2C, 35 Sq mm for Single Phase, 20 KVA 2C, 70Sq mm for Single Phase, 25 KVA 2C, 95Sq mm for Single Phase, 30 KVA 2C, 120Sq mm for Single Phase, 40 KVA 4C, 4 Sq mm for Three Phase,
SCOPE OF INSTALLATION Scope of installation for Diesel Generating Set when offered by the vendor - inclusive in the scope of supply(Part-3) d) 10 KVA 4C, 6 Sq mm for Three Phase, 15 KVA 4C, 10 Sq mm for Three Phase, 20 & 25 KVA 4C, 16 Sq mm for Three Phase, 30 KVA 3.5C, 25 Sq mm for Three Phase, 40 KVA 3.5C, 35 Sq mm for Three Phase, 50 KVA 3.5C, 70 Sq mm for Three Phase, 62.5 & 75 KVA 3.5C, 95 Sq mm for Three Phase, 82.5 KVA 3.5C, 120 Sq mm for Three Phase, 100 KVA 3.5C, 185 Sq mm for Three Phase, 125 KVA 3.5C, 300 Sq mm for Three Phase, 160 KVA 3.5C, 2 Run of 120 Sq mm for Three Phase, 180 KVA 3.5C, 2 Run of 150 Sq mm for Three Phase, 200 KVA 3.5C, 2 Run of 185 Sq mm for Three Phase, 225 KVA 3.5C, 2 Run of 240 Sq mm for Three Phase, 250 & 275 KVA 3.5C, 3 Run of 185 Sq mm for Three Phase, 320 KVA 3.5C, 3 Run of 240 Sq mm for Three Phase, 380 & 400 KVA 3.5C, 4 Run of 240 Sq mm for Three Phase, 500, 600 & 750 KVA 3.5C, 6 Run of 240 Sq mm for Three Phase, 900 KVA
SCOPE OF INSTALLATION Scope of installation for Diesel Generating Set when offered by the vendor - inclusive in the scope of supply(Part-4) e) Construction of suitable earthing station and necessary connections shall be done by the seller. All the materials / labour required for construction of earthing station shall be supplied by the seller. The total number of earthing pits/stations shall be 4, i.e., 2 for neutral and 2 for body-earthing. Netutral earthing shall be done with copper Plate and Body earthing shall be done with G.I. plate / Copper. The consignee should choose installation site in such a way that the earthing stations can be made within 10 metres of the Power Generator. Earthing station shall be typically constructed as per prevalent standard practices and shall be generally conforming to CPWD General specification for Electrical Works, Part - VII & Part - I - latest. e) Installation of Fuel Tank including foundation / stand shall be done by the seller. f)The warranty is applicable upto specified value of month/hours whichever occurs first's.
WARRANTY/SERVICES Warranty on Complete power genertor/DG Set 24, 36 Or higher
WARRANTY/SERVICES Warranty in running hours 5000.0 - 5000.0 Or higher
WARRANTY/SERVICES Number of preventive maintenance visits offered in an year during warranty period (Supply of all consumables is the buyer's responsibilty)* 2, 1
TEST REPORTS Test report Available for (Test/approval) Type Approval Certificate for the specified rating of the Power Generator from any of the designated agency authorized by CPCB, COP Certificate for engine, Type test report for Alternator as per IS:13364 (Part-1) latest / IS:13364 (Part-2) latest to prove conformity to the specifications

🤖 AI-Powered Bidder Prediction

Discover companies most likely to bid on this tender

Live AI
Historical Data

Required Documents

1

Experience Criteria

2

Past Performance

3

Bidder Turnover

4

Certificate (Requested in ATC)

5

OEM Authorization Certificate

6

OEM Annual Turnover *In case any bidder is seeking exemption from Experience / Turnover Criteria

7

the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer

Similar Tenders

5 found

N/A District & Sessions Judge Bilaspur Power Generator DG Set Tender 900 KVA Bilaspur Chhattisgarh 2026

N/a

📍 BILASPUR, CHHATTISGARH

EMD: ₹1.3 L
⏰ Deadline: 5 weeks left
🛒 Type: Goods
View GEM

Power Generator - DG Set (up to 900 KVA)

Southern Railway

📍 VIRUDHUNAGAR, TAMIL NADU

EMD: ₹1.4 L
⏰ Deadline: 5 weeks left
🛒 Type: Goods
View GEM

Parabolic Reflector Antenna Set: a) 0.5-2 Ghz PRA, b) 2-6 Ghz PRA, c) 6-18Ghz PRA (01 SET),Power Am

Office Of Dg (ecs)

📍 HYDERABAD, TELANGANA

EMD: ₹2.0 L
⏰ Deadline: 3 weeks left
🛒 Type: Goods
View GEM

Cranking Batteries for 4X3000 KVA Diesel Generator Station

Nmdc Steel Limited

📍 BASTAR, CHHATTISGARH

⏰ Deadline: 3 weeks left
🛒 Type: Goods
View GEM

Customized AMC/CMC for Pre-owned Products - 2x15 kVA UPS System; Hitachi Hirel Power Electronics Pv

N/a

📍 INDORE, MADHYA PRADESH

⏰ Deadline: 3 weeks left
🛒 Type: Service
View GEM