Central Board of Direct Taxes Diesel Generator Tender 900 KVA Ghaziapur Uttar Pradesh 2026
Central Board Of Direct Taxes (cbdt)
BALLIA, UTTAR PRADESH
Bid Publish Date
18-Jun-2026, 4:48 pm
Bid End Date
09-Jul-2026, 12:00 pm
EMD
₹84,380
Location
Progress
Quantity
5
Bid Type
Two Packet Bid
Public procurement opportunity for Munitions India Limited Diesel Power Generator (up to 900 KVA) (Q2) in HOSHANGABAD, MADHYA PRADESH. Quantity: 5 issued by. Submission Deadline: 09-07-2026 12: 00: 00. View full details and respond.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
Diesel Power Generator (up to 900 KVA) (Q2)
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
OTHER
CATALOG Specification
OTHER
OTHER
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Central Board Of Direct Taxes (cbdt)
BALLIA, UTTAR PRADESH
Central Board Of Direct Taxes (cbdt)
FATEHPUR, UTTAR PRADESH
N/a
PATHANAMTHITTA, KERALA
N/a
UDHAM SINGH NAGAR, UTTARAKHAND
E-municipalities - Eservices To Citizens And Employees Of Urban Local Bodies Of Uttar Pradesh
GORAKHPUR, UTTAR PRADESH
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| Installation Configuration | Power Generator Installation Configurations as per CPWD General Specifications for Electrical Works – Part VII (DG Set) | Fixed (Power Generators are permanently installed)" |
| Ratings | Nominal Rated Capacity (in kVA) | 40 |
| Engine | Rated Engine Power (kWm) | 110 % of the required powered at STP(Standard Temperature Pressure) i.e equal to (Nominal Rated Capacity (KVA) of power generator Any Auxilary power Consumption by the Power generator) x Power factor(0.8) / Alternator efficience Or higher |
| Engine | Type of Governor | Electronic Or higher |
| Engine | Rated Engine Speed (in RPM) | 1500 |
| Engine | Type of Fuel | High Speed Diesel (HSD) |
| Alternator | Voltage Regulation Grade | VG 3 Or higher |
| Control Panel | Type of Control Panel | AMF Control Panel |
| Trailer | Availability of Trailer | NA for Fixed/Skid Mounted Power Generator |
| Installation Requirement | Scope of installation for diesel generating set when offered by the vendor - inclusive in the scope of supply (Part-1) | a) Installation of Power Generator when offered by the vendor is inclusive in the scope of supply and shall be done by the seller. The installation work of Power Generator and its constituent parts shall be generally conforming to CPWD General Specification for Electrical Works, Part - VII - latest. b) Foundation shall be constructed by the seller. Foundation shall be of PCC type with the ratio of 4:2:1. The length and breadth of the foundation shall be 300 mm more from the respective length and breadth of the Power Generator. The height of the foundation shall be 400 mm, i.e., 200 mm below and 200 mm above the ground level. All the materials / labour required for foundation work shall be supplied by the seller. |
| Installation Requirement | Scope of installation for diesel generating set when offered by the vendor - inclusive in the scope of supply (Part-2) | c) Supply, laying and termination of interconnecting power and control cable shall be done by the seller. The cable supplied shall be ISI marked heavy duty PVC insulated, armoured cable, with PVC outer Sheath of Type ST-2 (FR Grade, Category C1), with aluminium conductor having insulation of PVC compound type -C, suitable for rated voltage upto and including 1100 volts and conforming to IS: 1554 (Part-1) latest. For 3-Phase Power Generators, 3.5 core or higher core cables shall be used. Total length of the cable supplied by the seller shall be within 30 meters for each Power Generator with manual control panel and within 60 metres for each Power Generator with AMF control panel. The current rating of the cables shall be as indicated below: 2C, 6 Sq mm for Single Phase, 3.5 & 5.0 KVA 2C, 10 Sq mm for Single Phase, 7.5 & 10 KVA 2C, 25 Sq mm for Single Phase, 15 KVA 2C, 35 Sq mm for Single Phase, 20 KVA 2C, 70Sq mm for Single Phase, 25 KVA 2C, 95Sq mm for Single Phase, 30 KVA 2C, 120Sq mm for Single Phase, 40 KVA 4C, 4 Sq mm for Three Phase, |
| Installation Requirement | Scope of installation for diesel generating set when offered by the vendor - inclusive in the scope of supply (Part-3) | d) 10 KVA 4C, 6 Sq mm for Three Phase, 15 KVA 4C, 10 Sq mm for Three Phase, 20 & 25 KVA 4C, 16 Sq mm for Three Phase, 30 KVA 3.5C, 25 Sq mm for Three Phase, 40 KVA 3.5C, 35 Sq mm for Three Phase, 50 KVA 3.5C, 70 Sq mm for Three Phase, 62.5 & 75 KVA 3.5C, 95 Sq mm for Three Phase, 82.5 KVA 3.5C, 120 Sq mm for Three Phase, 100 KVA 3.5C, 185 Sq mm for Three Phase, 125 KVA 3.5C, 300 Sq mm for Three Phase, 160 KVA 3.5C, 2 Run of 120 Sq mm for Three Phase, 180 KVA 3.5C, 2 Run of 150 Sq mm for Three Phase, 200 KVA 3.5C, 2 Run of 185 Sq mm for Three Phase, 225 KVA 3.5C, 2 Run of 240 Sq mm for Three Phase, 250 & 275 KVA 3.5C, 3 Run of 185 Sq mm for Three Phase, 320 KVA 3.5C, 3 Run of 240 Sq mm for Three Phase, 380 & 400 KVA 3.5C, 4 Run of 240 Sq mm for Three Phase, 500, 600 & 750 KVA 3.5C, 6 Run of 240 Sq mm for Three Phase, 900 KVA |
| Installation Requirement | Scope of installation for diesel generating set when offered by the vendor - inclusive in the scope of supply (Part-4) | e) Construction of suitable earthing station and necessary connections shall be done by the seller. All the materials / labour required for construction of earthing station shall be supplied by the seller. The total number of earthing pits/stations shall be 4, i.e., 2 for neutral and 2 for body-earthing. Netutral earthing shall be done with copper Plate and Body earthing shall be done with G.I. plate / Copper. The consignee should choose installation site in such a way that the earthing stations can be made within 10 metres of the Power Generator. Earthing station shall be typically constructed as per prevalent standard practices and shall be generally conforming to CPWD General specification for Electrical Works, Part - VII & Part - I - latest. e) Installation of Fuel Tank including foundation / stand shall be done by the seller. f)The warranty is applicable upto specified value of month/hours whichever occurs first's. |
Discover companies most likely to bid on this tender
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Additional Doc 1 (Requested in ATC)
Additional Doc 2 (Requested in ATC)
Additional Doc 3 (Requested in ATC)
Additional Doc 4 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Bharat Petroleum Corporation Ltd
📍 CHATRA, JHARKHAND
Puducherry Women's Commission
📍 PONDICHERRY, PUDUCHERRY
State Bank Of India (sbi)
📍 KOLLAM, KERALA
Uttar Pradesh Police
📍 SULTANPUR, UTTAR PRADESH
Urban Development And Housing Department
📍 PURNIA, BIHAR
Sign up now to access all documents
Main Document
OTHER
CATALOG Specification
OTHER
OTHER
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS