Online Ups Modular Type
Indian Army
TINSUKIA, ASSAM
Bid Publish Date
11-Jul-2026, 10:54 am
Bid End Date
01-Aug-2026, 11:00 am
EMD
₹24,000
Value
₹24,00,000
Location
Progress
Quantity
3
Bid Type
Two Packet Bid
Public procurement opportunity for Sanjay Gandhi Post Graduate Institute Of Medical Sciences Lucknow Online Ups Modular Type (Q3) in LUCKNOW, UTTAR PRADESH. Quantity: 3 issued by. Submission Deadline: 01-08-2026 11: 00: 00. View full details and respond.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
Online Ups Modular Type (Q3)
Advisory Bank
State Bank of India
ePBG Percentage
5%
ePBG Duration (Months)
62
Max Delivery Days
90
Delivery Locations
1
Delivery Cities
Lucknow
Delivery Pincodes
226014
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| Jamal Khalil | 226014,SANJAY GANDHI POSTGRADUATE INSTITIUTE OF MEDICAL SCIENCES LUCKNOW 226014 | Lucknow | Uttar Pradesh | 226014 | 3 | 90 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
OTHER
GEM_GENERAL_TERMS_AND_CONDITIONS
Indian Army
TINSUKIA, ASSAM
Directorate Of Municipal Administration
DAVANGARE, KARNATAKA
State Bank Of India (sbi)
Rangareddi, TELANGANA
Latur District Panchayats
LATUR, MAHARASHTRA
Bureau Of Police Research And Development (bpr&d)
SOUTH WEST DELHI, DELHI
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| GENERIC | Output power capacity including redundancy/Expandable (Rack facility) upto/Minimum backuptime (including redundancy) /Minimum VAH (VAH shall be calculated Battery voltage x Battery Ah x No. of batteries = Total VAH) | 150 KVA/240KVA/15 Minutes/61500 VAH, 150 KVA/240KVA/30 Minutes/123000 VAH, 150 KVA/240KVA/45 Minutes/184500 VAH, 150 KVA/250KVA/15 Minutes/61500 VAH, 150 KVA/250KVA/30 Minutes/123000 VAH, 150 KVA/250KVA/45 Minutes/184500 VAH, 160 KVA/240KVA/15 Minutes/65600 VAH, 160 KVA/240KVA/30 Minutes/131200 VAH, 160 KVA/240KVA/45 Minutes/196800 VAH, 160 KVA/250KVA/15 Minutes/61500 VAH, 160 KVA/250KVA/30 Minutes/123000 VAH, 160 KVA/250KVA/45 Minutes/184500 VAH, 60 KVA/120KVA/15 Minutes/24600 VAH, 60 KVA/120KVA/30 Minutes/49200 VAH, 60 KVA/120KVA/45 Minutes/73800 VAH, 4KVA/8KVA/6 minutes/1080 VAH, 8KVA/16KVA/6 minutes/2160 VAH, 16KVA/32KVA/6 minutes/4320 VAH, 100 KVA/200 KVA/15 Minutes/72000 VAH, 100 KVA / 150 KVA / 30 Minutes / 82000 VAH, 120 KVA / 125 KVA / 30 Minutes / 76800 VAH, 160 KVA / 240 KVA / 60 Minutes / 262400 VAH, 120 KVA / 240 KVA / 30 Minutes / 100800 VAH, 40KVA with 15/ 30 min backup 50KVA with 15/ 30 min backup 80KVA with 15/ 30 min backup, 60 KVA / 240 KVA / 30 Minutes / 50400 VAH, 60 KVA / 150 KVA / 60 Minutes / 103680 VAH, 10 KVA / 20 KVA / 30 Minutes / 15600 VAH, 15 KVA/ 30 KVA/ 30 Minutes/ 24000 VAH, 40 KVA/ 100 KVA/ 30 Minutes/ 20160 VAH, 500 KVA/ 500 KVA/ 30 Minutes/ 360000 VAH, 300 KVA/300 KVA/15 Minutes/ 163200 VAH |
| GENERIC | Noise level | |
| INPUT | In put Voltage Range | 320 V to AC to 470 V AC 3 Phase, 340 V to AC to 470 V AC 3 Phase |
| INPUT | Input frequency range | 50 +/-6% Hz, 50 +/-10% Hz |
| INPUT | Distortion (current) | < / = 3%, < / = 5% |
| OUTPUT | Output powr factor | >/= 0.90, >/=0.99 |
| CONSTRUCTION | Minimum thickness (in mm) of Rack Enclosure for Modular UPS duly powder coated | 2.0, 1.2, others |
| CONSTRUCTION | UPS enclosure's degree of protection as per IS:13947 (Part 1)/1993 latest | IP21, IP20 |
| CONSTRUCTION | Total Harmonic Distrotion (THD) for 100% linear load | < 3%, < 2% |
| CONSTRUCTION | Total Harmonic Distrotion (THD) for 100% non-linear load | < 5%, < 4% |
| CONSTRUCTION | Over all efficiency on rated full load of 0.8 PF (min.) AC output | >/=90%, >/=92%, >/=94%, >/=96% |
| CONSTRUCTION | Inverter efficiency on rated full load of 0.8 PF (min.) AC output | >/=95%, >/=96% |
| CONSTRUCTION | UPS shall withstand Over load capacity - 125% (Output with mains AC-AC) | for 5 Minutes (Minimum), for 10 Minutes (Minimum) |
| CONSTRUCTION | UPS shall withstand Over load capacity - 125% (Output in battery run DC-AC) | for 2 Minutes (Minimum), for 30 Seconds (Minimum) |
| BATTERY | Battery type | SMF VRLA, SMF VRLA, Modular Hot swappable Battery modules, Lithium Ion Battery [ as per IS 16046 (part 2)/ IEC 62133-2 and as per IEC 62485-5] |
| BATTERY | Battery recharge time (after complete discharge to 90% charge) and charge rating: Battery recharge time to 90% charge after 100% DoD | 8 to 10 hours, 4 to 8 hours |
| BATTERY | Batteries shall supply with | With metal rack, With Modular cabinet having hot swappable battery |
| WARRANTY AND SERVICES | Warranty for Modular UPS (on site comprehensive warranty) (in years) | 3, 5, others |
| WARRANTY AND SERVICES | Warranty for battery (replacement warranty) (in years) | 2, 3, 5, others |
| WARRANTY AND SERVICES | After sales and complaint service | within 24 hours, within 48 hours, Within 7 days |
| WARRANTY AND SERVICES | PAN India service support on 24 x 7 basis | Yes, No |
| WARRANTY AND SERVICES | AMC support available after 3 year warranty | Yes, No |
| WARRANTY AND SERVICES | Quarterly preventive maintenance | Yes, No |
| WARRANTY AND SERVICES | Manufacturer shall provide and support for installation, commissioning, spares, technical support all over India | Yes, No |
| WARRANTY AND SERVICES | Availability of spares in close proximity (Spares should be easily available close to the site) | Yes, No |
| CERTIFICATIONS | CE Certification and marking | Yes, No |
| CERTIFICATIONS | Damp Heat Test : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C,two cycles of (12+12) hours each 2007) | Yes, No |
| CERTIFICATIONS | Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs | Yes, No |
| CERTIFICATIONS | Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. | Yes, No |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Additional Doc 1 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Hindustan Aeronautics Limited (hal)
📍 LUCKNOW, UTTAR PRADESH
Border Security Force (bsf)
📍 DHUBRI, ASSAM
Directorate of Technical Education
📍 TIRUCHIRAPPALLI, TAMIL NADU
N/a
📍 CENTRAL DELHI, DELHI
Kamdhenu University
📍 BANASKANTHA, GUJARAT
Sign up now to access all documents
Main Document
CATALOG Specification
OTHER
GEM_GENERAL_TERMS_AND_CONDITIONS