Gas Chromatography
Directorate General Factory Advice Service And Labour Institutes (dgfasli)
Bid Publish Date
17-Feb-2026, 12:14 pm
Bid End Date
27-Feb-2026, 1:00 pm
EMD
₹2,60,000
Location
Progress
Quantity
1
Bid Type
Two Packet Bid
Department Of Drugs Control announces a tender for Gas Chromatography (Q3) in PONDICHERRY, PUDUCHERRY. Quantity: 1. Submission Deadline: 27-02-2026 13: 00: 00. Last date to apply is approaching fast!
Main Document
CATALOG Specification
GEM_GENERAL_TERMS_AND_CONDITIONS
Directorate General Factory Advice Service And Labour Institutes (dgfasli)
Directorate Of Forensic Science
Agharkar Research Institute (ari)
PUNE, MAHARASHTRA
Agharkar Research Institute (ari)
PUNE, MAHARASHTRA
University Of Kashmir
SRINAGAR, JAMMU & KASHMIR
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "GC Detectors inclusive in the scope of supply (Select Only those Detectors, which are part of supply)" | Flame Ionization Detector (FID) |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of FID in the System - inclusive in the scope of Supply (Select '0' if this Detector is not a part of supply)" | 1 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of TCD in the System - inclusive in the scope of Supply (Select '0' if this Detector is not a part of supply)" | 0 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of ECD in the System - inclusive in the scope of Supply (Select '0' if this Detector is not a part of supply)" | 0 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of NPD/FTD in the System - inclusive in the scope of Supply (Select '0' if this Detector is not a part of supply)" | 0 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of FPD in the System - inclusive in the scope of Supply (Select '0' if this Detector is not a part of supply)" | 0 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of PID in the System - inclusive in the scope of Supply (Select '0' if this Detector is not a part of supply)" | 0 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of PFPD in the System - inclusive in the scope of Supply (Select '0' if this Detector is not a part of supply)" | 0 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | Number of Inlets GC can Simultaneously Support | 3 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | Number of Detectors (Ports) GC can Simultaneously Support | 4 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | Number of Capillary Columns provided in GC - inclusive in the scope of Supply | 2 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | Type of Capillary Column | Polar |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "GC Capillary Column Length (Hint:-Select '0' if Not Applicable)" | 30.0 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "GC Capillary Column Internal Diameter (Hint:-Select '0' if Not Applicable)" | 0.32 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "GC Capillary Column Film Thickness (Hint:-Select '0' if Not Applicable)" | 0.25 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of Packed Columns provided in GC - inclusive in the scope of Supply (Hint:-Select '0' if Not Applicable)" | 0 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "GC Packed Column Length (Hint:-Select '0' if Not Applicable)" | 0.0 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "GC Packed Column Internal Diameter (Hint:-Select '0' if Not Applicable)" | 0 |
| PERFORMANCE | "GC Detector Minimum Detection Level (MDL) " | < 1.4 pg C/s for FID |
| PERFORMANCE | GC Detector Linear Dynamic Range (± 10%) | NA |
| PERFORMANCE | GC Detector Data acquisition rate | NA |
| COLUMN OVEN (GAS CHROMATOGRAPH - GC) | Maximum Operating Temperature (GC Oven) | upto 450 deg. C (2) Or higher |
| COLUMN OVEN (GAS CHROMATOGRAPH - GC) | Oven cool down time from Max operating temperature to 50 Deg c | 3.5, 4 Or lower |
| COLUMN OVEN (GAS CHROMATOGRAPH - GC) | Number of Oven Ramps / Plateaus for Temperature programming | 20/21 or more |
| COLUMN OVEN (GAS CHROMATOGRAPH - GC) | Temperature Ramp Rate - Maximum | 120 Deg. C/minute or better |
| COLUMN OVEN (GAS CHROMATOGRAPH - GC) | Retention time repeatability | 0.01 |
| COLUMN OVEN (GAS CHROMATOGRAPH - GC) | Temperature set point resolution (±) | 0.1 |
| PNEUMATIC CONTROL | "Type of Inlet Pneumatics (Select applicable parameters only)" | Advanced Flow Controller (AFC), Advanced Pressure Controller (APC) |
| PNEUMATIC CONTROL | Number of Injection Ports | 1 |
| PNEUMATIC CONTROL | Maximum Injection Port heating Temperature | upto 450 deg. C (2) Or higher |
| PNEUMATIC CONTROL | Pressure Range | upto 120 psi (2) Or higher |
| PNEUMATIC CONTROL | Pressure set point Resolution (±)(psi) | 0.001 Or lower |
| PNEUMATIC CONTROL | Type of Sample Injection Port | split / Splitless |
| PNEUMATIC CONTROL | Split Ratio | 7500:1 |
| PNEUMATIC CONTROL | Modes of Operation | Constant flow, Constant Pressure, Programmable Flow |
| AUTO INJECTOR / AUTO SAMPLER | Compatible Liquid Auto Sampler - inclusive in the scope of supply | Yes |
| AUTO INJECTOR / AUTO SAMPLER | Capacity of the Liquid Auto Sampler (Number of Vials) | 150 Or higher |
| AUTO INJECTOR / AUTO SAMPLER | Volume of each Vial of the Liquid Auto Sampler | 2.0 |
| AUTO INJECTOR / AUTO SAMPLER | Number of Injection Ports in the Liquid Auto Sampler | 1 |
| AUTO INJECTOR / AUTO SAMPLER | Number of Channels in the Liquid Auto Sampler | 0 |
| AUTO INJECTOR / AUTO SAMPLER | Minimum Volume of the injected liquid sample | 0.1 |
| AUTO INJECTOR / AUTO SAMPLER | Maximum Volume of the injected liquid sample | 10.0 |
| AUTO INJECTOR / AUTO SAMPLER | Operating Voltage of the Liquid Auto Sampler | 230 V ± 10% |
| AUTO INJECTOR / AUTO SAMPLER | "Liquid Auto Sampler Features (Select applicable features Only)" | Fully automated Liquid Auto Sampler |
| HEAD SPACE SAMPLER | Compatible Head Space Sampler- inclusive in the scope of supply | Yes |
| HEAD SPACE SAMPLER | Capacity of the Head Space Sampler Carousel (number of Vials) | 12 or better |
| HEAD SPACE SAMPLER | Head Space Sampler Temperature Range | Upto 200 deg. C or better |
| HEAD SPACE SAMPLER | "Head Space Sampler Features (Select applicable features Only)" | Built-in Sample Shaker, Operates through Software with single keyboard controls (Software inclusive in the scope of supply); |
| PYROLYZER SYSTEM | Compatible Pyrolyzer System for pyrolysis of solid and liquid samples- inclusive in the scope of supply | No |
| PYROLYZER SYSTEM | Temperature in the Pyrolyzer System | NA |
| SALIENT FEATURES OF GAS CHROMATOGRAPH (GC) | "Salient Featutes of GC (Select applicable features Only)" | Automatic leak testing/detection of Pneumatics |
| SOFTWARE | "Software Features (Select Applicable Features only)" | Compatible with Windows 7 or higher version operating system, Seamless integration & control of all the GC parameters |
| GENERIC | Power Supply | 230 V ± 10% |
| GENERIC | Display | Through PC (PC is not part of supply) |
| GENERIC | Display Size(In case of Built-in Display) | 7.0 - 10.0 Or higher |
| GENERIC | Connectivity interface | USB |
| GENERIC | Provision to split the sample from single injection to two different detectors and get results for two detectors simultaneously | No |
| ACESSORIES | Gas Supply inclusive in the scope of supply | Nitrogen, Hydrogen, Zero Air |
| ACESSORIES | Capacity of Gas cylinder | 47 liters water capacity |
| ACESSORIES | Number of Cyliners of each type supplied - inclusive in the scope of supply | 1 |
| ACESSORIES | Gas cylinders certified by PESO | Yes |
| ACESSORIES | Regulator - inclusive in the scope of supply | Dual Stage Regulator |
| ACESSORIES | "Other Accessories inclusive in the scope of supply (Select only those Accessories which are part of supply)" | Gas purification panel for all Gases with moisture trap, Hydrocarbon trap & Oxygen trap, Graphite ferrules x 10 nos, Vessel ferrules x 10 nos, Inlet liner for splitles x 4 nos, Inlet liner for split x 4 nos, Tool Kit x 1 no., User / Technical / Maintenance Manual |
| ENVIRONMENTAL | Minimum Operating Temperature | 0.0 - 10.0 Or lower |
| ENVIRONMENTAL | Maximum Operating Temperature | 40.0 - 65.0 Or higher |
| ENVIRONMENTAL | Operating Humidity (RH) (%) at 40 degree C | 70.0 - 95.0 Or higher |
| INSTALLATION & COMMISSIONING / WARRANTY / AVAILABILITY OF SPARES / TRAINING | Warranty on equipment | 5.0 |
| INSTALLATION & COMMISSIONING / WARRANTY / AVAILABILITY OF SPARES / TRAINING | Number of days onsite training provided | 5.0 |
| INSTALLATION & COMMISSIONING / WARRANTY / AVAILABILITY OF SPARES / TRAINING | Number of Year Availability of Spares from the date of installation is assured | 7.0 |
| CERTIFICATION / TEST REPORT | "Availability of UL/CE Certificate as per IEC 61010- 1 latest - Safety requirements for electrical equipment for measurement,control, and laboratory use General requirements" | Yes |
| CERTIFICATION / TEST REPORT | Conformance to EMC/EMI as per IEC 61326-1 latest - Electrical equipment for measurement, control and laboratory use | No |
| CERTIFICATION / TEST REPORT | Availability of Test Reports from Central Govt / NABL approved / ILAC accredited Lab to prove conformity to the specification | No |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Council Of Scientific And Industrial Research (csir)
📍 DEHRADUN, UTTARAKHAND
Food Safety And Drug Administration
📍 VARANASI, UTTAR PRADESH
National Institute Of Technology (nit)
Sign up now to access all documents
Main Document
CATALOG Specification
GEM_GENERAL_TERMS_AND_CONDITIONS