TenderDekho Logo
GEM

Invitation to Bid - Visit charges to attend fault of DEA Set on call basis,Pdg and Making of General Servicing of the E

Bid Publish Date

08-Nov-2024, 1:10 pm

Bid End Date

02-Dec-2024, 3:00 pm

EMD

₹11,432

Progress

Issue08-Nov-2024, 1:10 pm
AwardPending
Explore all 4 tabs to view complete tender details

Quantity

1342

Category

Visit charges to attend fault of DEA Set on call basis

Bid Type

Two Packet Bid

Categories 204

FILTERS PLATFORM SCALE PUSH BUTTON SWITCHES AXLE ALTERNATOR RING POWER CABLE AIR CYLINDERS VEHICLE CONTROL WIRE DECORATION AIR COOLED ENGINE BUS CABLE WIRING ASSEMBLY HEATING EQUIPMENTS SPRAYER DIRECT TRANSFORMER RADIO FREQUENCY ANALYSER AIR REGULATORS GEYSER COUNTER BATTERY CHARGERS STEEL WIRE LIGHTENING PROTECTION DEVICE WATTMETERS SOIL EARTH AMC OF ELECTRONIC GENERATOR SPARE COOLANT ARTICULATING LAZY ARMS SYNCHRONOUS MOTORS ULTRACENTRIFUGES MICRO CONTROLLER ENGINE OIL MATERIAL UNLOADING TRANSPORTATION NOZZLE ENGINE POWER CONTROL CABLE BUS TERMINAL OIL GAUGES COILED CABLE MACHINING AND PROCESSING SERVICES PVC CABLE FUEL INJECTION MACHINE BELT RF PASSIVE COMPONENTS PNEUMATIC PRESSURE GAUGE LUBRICANT PRODUCT ROTARY CAM PUMPS VALVES WEIGH BRIDGE THERMOWELLS PRESSURE REGULATOR WATER GENERATOR CHAIN PULLEY TRANSPORTATION OF DIESEL EXCITATION SYSTEM SANITARY FITTING WIRE FILTER RETAINERS ENT SET OIL FILTERS WORM GEAR ROUTINE MAINTENANCE SMART POSITIONER FILLING RAIN CUT SLIDER VALVES DIAPHRAGM PUMPS PYROMETERS HYDRAULIC CYLINDER LUBE OIL GAUGE BATTERY VALVE PARTS AND ACCESSORIES SOLID ROCKET MOTORS VEHICLE BATTERIES ESCRAP CANOPY GENERATOR REPAIR ARM CHAIR PEB PULLEY ALUMINUM BOYLES APPARATUS MINERAL WEIGHTS SLEEVE BEARING BP INSTRUMENT WIND MILL ENERGY PROJECT DECIBEL METER APFC PANEL ARCHERY BOW STRINGS CENTRIFUGE BRUSHES FUSES PARAMETER TEST ISDN BICYCLE CONING OIL TESTING INSTRUMENT PERISTALTIC PUMPS ARNO STARTING CONTACTOR BEARINGS MOBIL OIL WIRING SPECIFICATION DISTRIBUTION?BOX WHEAT FLOUR BEARINGS BUSHINGS AND GEARS AMPS LUBRICATING OILS SWITCHING APPARATUS ARC VALVE HARDWARE AND FASTENERS WELL TESTING EQUIPMENTS XLPE CABLE RUBBER GASKET INSULATED WIRE SNG WOODEN FLOORING ALTERNATOR FAN SPARE PARTS INSTRUMENTATION CABLE COATING SERVICES MI TANK STATIC CONVERTERS MUSICAL INSTRUMENT PARTS AND ACCESSORIES THICKNESS GAUGE MINING ENGINEERING ENGINE PARTS WINDING MACHINE MAINTENANCE CONTRACT OF ELECTRONIC CONDUCTOR INDICATING AND RECORDING INSTRUMENTS PRESSURE WASHER CABLING PRESSURE INDICATORS SEALING RING BUCKET CONVEYORS MACHINE OIL PNEUMATIC POSITIONER BLASTING MACHINE PETROLEUM FUELS AUDIOMETERS EMG MACHINE METER READING WORK SWITCH GEAR VOLTMETER COMPRESSED AIR EARTH AND STONE HOOK UP WIRES OCEAN ENGINEERING DIODE GLUCOMETER ALTERNATING CURRENT MOTOR ELECTRON TUBE LABORATORY PRESSES GL WIRE CABLE LAYING CHANGE OVER SWITCH GASKETS AND SEALS PLAIN BEARING POWER WIRE AC MOTORS TECHNICAL SERVICES VALVE WATER LEVEL RECORDER WATER SUPPLY MATERIAL PRESSURE MEASURING AND CONTROL INSTRUMENTS AIR GENERATOR FUME HOODS BODYWEIGHT MEASURING SCALE FLUE GAS AIRCRAFT HYDRAULIC SYSTEMS BUSHING FLUORESCENT LAMP INDUCTION MOTORS ANAESTHESIA MACHINE BARE CABLE PROGRESSIVE CAVITY PUMPS SUPPLY OF ENGINE BACKHOE TRANSITION METALS ANGLE BRACKETS TRANSPORT CABLE FIRE BREATHING APPARATUS STARTER MACHINE HOSE PIPE INJECTORS RECTIFIERS GAS PIPELINE FILTERS EXCAVATION WATER COOLED ENGINE BUNDI CABLE SUPPLY ELECTROMAGNET EARTH MOVING LUBRICANT MEDICAL DIAGNOSTIC GAMMA CAMERAS SMPS AC AND DC POWER SUPPLY LABOUR

Bharat Sanchar Nigam Limited Portal(bsnl) invites bids for Visit charges to attend fault of DEA Set on call basis, Pdg and Making of General Servicing of the E. Quantity: 1342. Submission Deadline: 02-12-2024 15: 00: 00. Submit your proposal before the deadline.

Documents 5

GeM-Bidding-7115015.pdf

Main Document

BOQ Document

BOQ

BOQ Document

BOQ

Buyer uploaded ATC document

ATC

GEM General Terms and Conditions Document

GEM_GENERAL_TERMS_AND_CONDITIONS

Past Similar Tenders (Historical Results)

5 found

Indian Army Department Of Military Affairs Grass Cutting Wire, E Rickshaw Charger, Welding Rod, Gen Set 20 KVA Servicing Tender 2025

Indian Army

JHANSI, UTTAR PRADESH

Posted: 15 December 2025
Closed: 25 December 2025
GEM

Visit charges to attend fault of DEA Set,General Servicing of the Up to 20 KVA DEA sets,General Ser

Bharat Sanchar Nigam Limited Portal(bsnl)

JODHPUR, RAJASTHAN

Posted: 28 November 2025
Closed: 22 December 2025
GEM

REPAIR/ MAINTENANCE/ SERVICING OF SEWAGE TREATMENT PLANT INCL MISC WORK OF DG SET, LAUNDARY PLANT, OHT CRANES AND ARBORICULTURE WORK UNDER AGE E/M-II OF GE (SOUTH) MEERUT CANTT

E-IN-C BRANCH - MILITARY ENGINEER SERVICES

MEERUT, UTTAR PRADESH

Posted: 13 October 2025
Closed: 10 November 2025
EPROCURE

GeM Tender for Goods Supply - WCL Majri Area WARORA India 2025 with 25% Option Clause

N/A

CHANDRAPUR, MAHARASHTRA

Posted: 28 October 2025
Closed: 7 November 2025
GEM

Visit charges to attend fault of DEA Set,General Servicing of the Up to 20 KVA DEA sets,General Ser

Bharat Sanchar Nigam Limited Portal(bsnl)

JAIPUR, RAJASTHAN

Posted: 6 August 2025
Closed: 29 August 2025
GEM

Bill of Quantities (BOQ) 86 Items

Item # Title Description Quantity Unit Consignee Delivery (Days)
1 Visit charges to attend fault of DEA Set on call basis Visit charges to attend fault of DEA Set on call basis or complaint basis on behalf of written Job order from SDE E concerned for different TE or BTS sites under jurisdiction including attending the minor faults involving no material and submit detailed report for major fault to the Engineering In charge including fare charges to visit the site from HQ etc complete as reqd. 1 job maheshsol 180
2 Pdg and Making of General Servicing of the EA sets Pdg and Making of General Servicing of up to 20 KVA the EA sets of different make and model installed at Sites including complete checking of EA Set after servicing and replacement of consumables 10 job maheshsol 180
3 Pdg and Making of General Servicing of the EA sets Pdg and Making of General Servicing of More than 20 KVA and Upto 32.5 KVA DEA Sets of different make and model installed at Sites including complete checking of EA Set after servicing and replacement of consumables 2 job maheshsol 180
4 Pdg and Making of General Servicing of the EA sets Pdg and Making of General Servicing of More than 32.5 KVA and Upto 55 KVA DEA Sets of different make and model installed at Sites including complete checking of EA Set after servicing and replacement of consumables 2 job maheshsol 180
5 Replacement of the Diesel Filter Element Set of 1 Ltr capacity Replacement of the Diesel Filter Element Set of 1 Ltr in existing Different capacity and make of Engines including dismantling of faulty parts, fixing the new in place of faulty parts 4 set maheshsol 180
6 Replacement of the oil Filter Element Set of 0.5 Ltr capacity Replacement of the Oil Filter Element 0.5 Ltr in existing Different capacity and make of Engines including dismantling of faulty parts, fixing the new in place of faulty parts 12 each maheshsol 180
7 Replacement of the oil Filter Element Set of 1.0 Ltr capacity Replacement of the Oil Filter Element 1.0 Ltr in existing Different capacity and make of Engines including dismantling of faulty parts, fixing the new in place of faulty parts 4 each maheshsol 180
8 Replacement of the Diesel Filter Element Set of 0.5 Ltr capacity Replacement of the Diesel Filter Element Set of 0.5 Ltr in existing Different capacity and make of Engines including dismantling of faulty parts, fixing the new in place of faulty parts 12 set maheshsol 180
9 Replacement of the oil Filter Element Set of 50 and 55 KVA EA capacity Replacement of the Oil Filter Element sets in 50 and 55 KVA EA capacity including dismantling of faulty parts, fixing the new in place of faulty parts 2 each maheshsol 180
10 Replacement of Lubricating Oil Multi Grade Replacement of Lubricating Oil Multi Grade in existing Different capacity and make of Engines 100 liter maheshsol 180
11 Replacement of Steel Wire Braided Fuel Pipe Line Replacement of Steel Wire Braided Fuel Pipe Line in existing Different capacity and make of Engines 50 meter maheshsol 180
12 Replacement of Stop Solenoid 12 Volt Replacement of Stop Solenoid 12 Volt in existing Different capacity and make of Engines 1 each maheshsol 180
13 Replacement of Starting Key with Switch Replacement of Starting Key with Switch in existing Different capacity and make of Engines 5 each maheshsol 180
14 Replacement of Mechanical Type RPM Cum Hr Meter Replacement of Mechanical Type RPM Cum Hr Meter in existing Different capacity and make of Engines 1 each maheshsol 180
15 Replacement of Mechanical Type RPM Cum Hr Meter Chain Replacement of Mechanical Type RPM Cum Hr Meter chain in existing Different capacity and make of Engines 1 each maheshsol 180
16 Replacement of Battery Leads Red and Black Standard Length and Size including terminals Replacement of Battery Leads Red and Black Standard Length and Size including terminals in existing Different capacity and make of Engines 5 set maheshsol 180
17 Replacement of Coolant for Radiator Replacement of Coolant for Radiator of superior quality or as recommended by manufacturer in existing Different capacity and make of Engines 10 liter maheshsol 180
18 Replacement of V Belt Replacement of V Belt in existing Different capacity and make of Engines 5 each maheshsol 180
19 Replacement of Hose pipe set with clips Replacement of Hose pipe set with clips in existing Different capacity and make of Engines 2 set maheshsol 180
20 Replacement of Techo Drive Unit Replacement of Techo Drive Unit in existing Different capacity and make of Engines 1 each maheshsol 180
21 Replacement of Fuel Feed Pump assembly. Replacement of Fuel Feed Pump assembly in existing Different capacity and make of Engines 5 each maheshsol 180
22 Replacement of Solid state SMPS or SCR based battery chargers Replacement of Solid state SMPS or SCR based battery chargers suitable up to 12V, 180 AH Battery 8 each maheshsol 180
23 Replacement of Push Button Switch for Start , Stop, Reset Replacement of Fuel Feed Pump assembly in existing Different capacity and make of Engines 2 each maheshsol 180
24 Replacement of 12 V DC or 220 V AC HR Meter Counter Type Replacement of 12 V DC or 220 V AC HR Meter Counter Type in existing Different capacity and make of Engines 5 each maheshsol 180
25 Supplying and fixing of 12 Volt Battery Operated Self Starter Supplying and fixing of 12 Volt Battery Operated Self Starter suitable for Starting of Engine including fixing the same on the DG set making connections testing etc. 1 each maheshsol 180
26 Supplying and fixing of 12 Volt Battery Charging Alternator Supplying and fixing of 12 Volt Battery Charging Alternator on the existing DG set including making connections testing etc. 1 each maheshsol 180
27 Pdg General Servicing and Repairing of Battery Charging Alternator Pdg General Servicing and Repairing of Battery Charging Alternator or Dynamo that including dismantling greasing and oiling of bearings and other parts , repairing of rectifier assembly , replacement of carbon brush etc. 5 job maheshsol 180
28 Repairing and General Servicing of the existing faulty radiator up to 55 KVA DEA Set Repairing and General Servicing of the existing faulty radiator up to 55 KVA Diesel Engine alternator set by repairing of leakage and cleaning of copper tubes , dismantling of radiator assembly including transportation, and reinstallation after repairing the same etc. 5 job maheshsol 180
29 Pdg General servicing and Repairing of 12 Volts Engine Starting Self Pdg General servicing and Repairing of 12 Volts Engine Starting Self that including dismantling , greasing and oiling of bearing and other parts , replacement Carbon Brush, Housing etc. 5 job maheshsol 180
30 Dismantling of existing Up to 20 KVA DEA sets capacity in sound proof canopy Dismantling of existing Up to 20 KVA DEA sets capacity in sound proof canopy along with all existing accessories including disconnection of cabling, earthing strips etc set from existing position of TE or BTS site under BA Udaipur etc. and repairing of any damage during dismantling by making good the same etc. complete as reqd. 5 job maheshsol 180
31 Dismantling of existing More Than 20 KVA and Upto 55 KVA DEA Sets capacity in sound proof canopy Dismantling of existingMore Than 20 KVA and Upto 55 KVA DEA Sets capacity in sound proof canopy along with all existing accessories including disconnection of cabling, earthing strips etc set from existing position of TE or BTS site under BA Udaipur etc. and repairing of any damage during dismantling by making good the same etc. complete as reqd. 5 job maheshsol 180
32 Transportation of existing DEA sets Up to 20 KVA Capacity along with all accessories Transportation of existing DEA sets Up to 20 KVA Capacity along with all accessories etc from TE or BTS Site of OA under BA Udaipur to Store or Any Place in same BA as directed by Engg. in Charge by transport by truck , Loading Vehicle etc. complete as reqd. 4 job maheshsol 180
33 Transportation of existing DEA sets More Than 20 KVA and Upto 55 KVA DEA Sets Capacity along with all accessories Transportation of existing DEA sets More Than 20 KVA and Upto 55 KVA DEA Sets Capacity along with all accessories etc from TE or BTS Site of OA under BA Udaipur to Store or Any Place in same BA as directed by Engg. in Charge by transport by truck , Loading Vehicle etc. complete as reqd. 4 job maheshsol 180
34 Unloading of existing DEA sets Up to 20 KVA Capacity from Loading Vehicle to Place of Shifting Unloading of existing DEA sets Up to 20 KVA Capacity from Loading Vehicle to Place of Shifting Store along with all accessories etc as directed by Engg. in Charge with the help of chain pulley , Crane , Man power etc. complete as reqd. 5 job maheshsol 180
35 Unloading of existing DEA sets More Than 20 KVA and Upto 55 KVA Capacity from Loading Vehicle to Place of Shifting Unloading of existing DEA sets More Than 20 KVA and Upto 55 KVA Capacity from Loading Vehicle to Place of Shifting Store along with all accessories etc as directed by Engg. in Charge with the help of chain pulley , Crane , Man power etc. complete as reqd. 5 job maheshsol 180
36 Installation, Testing and Commissioning of existing DEA sets up to 20 KVA Capacity on existing foundation Installation, Testing and Commissioning of existing DEA sets up to 20 KVA Capacity on existing foundation or floor at site along with Canopy and all other accessories including making connections, power and control cable, earthing connections etc. complete as per requirement at Site. Testing Shall also be arranged by Contractor on existing load available at Site for at least one Hour after Commissioning of the DEA Set. Note - All necessary Material, T and P and Skilled Man Power etc. shall be on part of Contractor 3 job maheshsol 180
37 Installation, Testing and Commissioning of existing DEA sets More Than 20 KVA and Upto 55 KVA Capacity on existing foundation Installation, Testing and Commissioning of existing DEA sets More Than 20 KVA and Upto 55 KVA Capacity on existing foundation or floor at site along with Canopy and all other accessories including making connections, power and control cable, earthing connections etc. complete as per requirement at Site. Testing Shall also be arranged by Contractor on existing load available at Site for at least one Hour after Commissioning of the DEA Set. Note All necessary Material, T and P and Skilled Man Power etc. shall be on part of Contractor 2 job maheshsol 180
38 Labour Charges for Top Overhauling of existing DEA Sets up to 20 KVA Capacity of various Make and Model Labour Charges for Top Overhauling of existing DEA Sets up to 20 KVA Capacity of various Make and Model as per manufacturer recommendations including dismantling of all the filters like oil filters, diesel filter, air filter, tappet setting, cylinder head and cleaning of all carbonised parts, radiator cleaning, replacement of engine oil coolant, replacement of belts safeties, meters if reqd and calibration of engine as per manufacturer recommendations etc as required. 1 job maheshsol 180
39 Replacement of Liner assembly with rubber ring in existing DEA sets up to 20 KVA Capacity Replacement of the Liner assembly with rubber ring in existing DEA sets up to 20 KVA Capacity of various Make and Model as per manufacturer recommendations including dismantling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. 2 each maheshsol 180
40 Replacement of Piston Set without Piston Ring Set in existing DEA sets up to 20 KVA Capacity Replacement of the Piston Set without Piston Ring Set in existing DEA sets up to 20 KVA Capacity of various Make and Model as per manufacturer recommendations including dismantling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. 3 each maheshsol 180
41 Replacement of Piston Ring Set in existing DEA sets up to 20 KVA Capacity Replacement of Piston Ring Set in existing DEA sets up to 20 KVA Capacity of various Make and Model as per manufacturer recommendations including dismantling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. 3 each maheshsol 180
42 Replacement of Set of Gasket including Head Gasket in existing DEA sets up to 20 KVA Capacity Replacement of Set of Gasket including Head Gasket in existing DEA sets up to 20 KVA Capacity of various Make and Model as per manufacturer recommendations including dismantling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. 2 set maheshsol 180
43 Replacement of O Ring Set in existing DEA sets up to 20 KVA Capacity Replacement of O Ring Set in existing DEA sets up to 20 KVA Capacity of various Make and Model as per manufacturer recommendations including dismantling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. 2 set maheshsol 180
44 Replacement of CR Bearing in existing DEA sets up to 20 KVA Capacity Replacement of CR Bearing in existing DEA sets up to 20 KVA Capacity of various Make and Model as per manufacturer recommendations including dismantling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. 3 each maheshsol 180
45 Replacement of Main Bearing in existing DEA sets up to 20 KVA Capacity Replacement of Main Bearing in existing DEA sets up to 20 KVA Capacity of various Make and Model as per manufacturer recommendations including dismantling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. 3 each maheshsol 180
46 Replacement of Oil Pressure Gauge in existing DEA sets up to 20 KVA Capacity Replacement of Oil Pressure Gauge in existing DEA sets up to 20 KVA Capacity of various Make and Model as per manufacturer recommendations including dismantling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. 2 each maheshsol 180
47 Replacement of Front oil Seal ,Crank Shaft in existing DEA sets up to 20 KVA Capacity Replacement of Front oil Seal ,Crank Shaft in existing DEA sets up to 20 KVA Capacity of various Make and Model as per manufacturer recommendations including dismantling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. 2 set maheshsol 180
48 Replacement of Back oil Seal ,Crank Shaft in existing DEA sets up to 20 KVA Capacity Replacement of Back oil Seal ,Crank Shaft in existing DEA sets up to 20 KVA Capacity of various Make and Model as per manufacturer recommendations including dismantling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. 3 set maheshsol 180
49 Labour Charges for Top Overhauling of existing more than 20 KVA and upto 55 KVA Capacity Labour Charges for Top Overhauling of existing more than 20 KVA and upto 55 KVA Capacity DEA Sets of various Make and Model as per manufacturer recommendations including dismantling of all the filters like oil filters, diesel filter, air filter, tappet setting, cylinder head and cleaning of all carbonised parts, radiator cleaning, replacement of engine oil coolant, replacement of belts safeties, meters if reqd and calibration of engine as per manufacturer recommendations etc as required. 1 job maheshsol 180
50 Replacement of Liner assembly with rubber ring in existing DEA set more than 20 KVA and upto 55 KVA of Capacity Replacement of Liner assembly with rubber ring in existing DEA set more than 20 KVA and upto 55 KVA of Capacity of various Make and Model as per manufacturer recommendations including dismantling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. 1 each maheshsol 180
51 Replacement of Piston Set without Piston Ring Set in existing DEA set more than 20 KVA and upto 55 KVA of Capacity Replacement of Piston Set without Piston Ring Set in existing DEA set more than 20 KVA and upto 55 KVA of Capacity of various Make and Model as per manufacturer recommendations including dismantling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. 1 each maheshsol 180
52 Replacement of Piston Ring Set in existing DEA set more than 20 KVA and upto 55 KVA of Capacity Replacement of Piston Ring Set in existing DEA set more than 20 KVA and upto 55 KVA of Capacity of various Make and Model as per manufacturer recommendations including dismantling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. 1 each maheshsol 180
53 Replacement of Set of Gasket including Head Gasket in existing DEA set more than 20 KVA and upto 55 KVA of Capacity Replacement of Set of Gasket including Head Gasket in existing DEA set more than 20 KVA and upto 55 KVA of Capacity of various Make and Model as per manufacturer recommendations including dismantling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. 1 set maheshsol 180
54 Replacement of O Ring Set in existing DEA set more than 20 KVA and upto 55 KVA of Capacity Replacement of O Ring Set in existing DEA set more than 20 KVA and upto 55 KVA of Capacity of various Make and Model as per manufacturer recommendations including dismantling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. 1 set maheshsol 180
55 Replacement of CR Bearing in existing DEA set more than 20 KVA and upto 55 KVA of Capacity Replacement of CR Bearing in existing DEA set more than 20 KVA and upto 55 KVA of Capacity of various Make and Model as per manufacturer recommendations including dismantling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. 1 each maheshsol 180
56 Replacement of Main Bearing in existing DEA set more than 20 KVA and upto 55 KVA of Capacity Replacement of Main Bearing in existing DEA set more than 20 KVA and upto 55 KVA of Capacity of various Make and Model as per manufacturer recommendations including dismantling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. 1 each maheshsol 180
57 Replacement of Oil Pressure Gauge in existing DEA set more than 20 KVA and upto 55 KVA of Capacity Replacement of Oil Pressure Gauge in existing DEA set more than 20 KVA and upto 55 KVA of Capacity of various Make and Model as per manufacturer recommendations including dismantling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. 1 each maheshsol 180
58 Replacement of Front oil Seal Crank Shaft in existing DEA set more than 20 KVA and upto 55 KVA of Capacity Replacement of Front oil Seal, Crank Shaft in existing DEA set more than 20 KVA and upto 55 KVA of Capacity of various Make and Model as per manufacturer recommendations including dismantling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. 1 set maheshsol 180
59 Replacement of Back oil Seal Crank Shaft in existing DEA set more than 20 KVA and upto 55 KVA of Capacity Replacement of Back oil Seal, Crank Shaft in existing DEA set more than 20 KVA and upto 55 KVA of Capacity of various Make and Model as per manufacturer recommendations including dismantling of faulty parts, fixing the new in place of faulty parts , testing etc as reqd. 1 set maheshsol 180
60 Repairing of Cylinder Head , One Job for Each Head Repairing of Cylinder Head , One Job for Each Head, with replacement of valve seat, Valve guide, Valves and stamp seal including grinding , lapping of valves including turning, grinding of head etc complete as reqd. 1 job maheshsol 180
61 Repairing of Crank Shaft Up to 20 KVA DEA sets Repairing of Crank Shaft Up to 20 KVA DEA sets including Grinding , lapping , bushing, alignment etc complete as reqd. 1 job maheshsol 180
62 Repairing of Crank Shaft More Than 20 KVA and Upto 55 KVA DEA Sets Repairing of Crank Shaft More Than 20 KVA and Upto 55 KVA DEA Sets including Grinding , lapping , bushing, alignment etc complete as reqd. 1 job maheshsol 180
63 Transportation Charges for Alternator Upto 50 Km of various capacity up to 55 KVA Transportation Charges for Alternator Upto 50 Km of various capacity up to 55 KVA from Site to the nearest Workshop and back after repairing including Dismantling, loading, unloading, transportation, safe Handling and including reinstallation, making connections, power and control cable connections etc. and testing on existing load for at least one hour after commissioning of the Alternator etc. complete as reqd. 4 job maheshsol 180
64 Transportation Charges for Alternator More than 51 to 100 Km of various capacity up to 55 KVA Transportation Charges for Alternator More than 51 to 100 Km of various capacity up to 55 KVA from Site to the nearest Workshop and back after repairing including Dismantling, loading, unloading, transportation, safe Handling and including reinstallation, making connections, power and control cable connections etc. and testing on existing load for at least one hour after commissioning of the Alternator etc. complete as reqd. 1 job maheshsol 180
65 Rewinding of Main Stator winding of Alternator Capacity up to 20 KVA of existing faulty Alternator Rewinding of Main Stator winding of Alternator Capacity up to 20 KVA of existing faulty Alternator of various Makes with suitable size copper enameled wire including providing insulation of appropriate class, varnishing, assembling including testing etc complete as required. 2 job maheshsol 180
66 Rewinding of Main Rotor winding of Alternator Capacity up to 20 KVA of existing faulty Alternator Rewinding of Main Rotor winding of Alternator Capacity up to 20 KVA of existing faulty Alternator of various Makes with suitable size copper enameled wire including providing insulation of appropriate class, varnishing, assembling including testing etc complete as required. 2 job maheshsol 180
67 Rewinding of Main Stator winding of Alternator Capacity more than 20 KVA and Up to 50 or 55 KVA of existing faulty Alternator Rewinding of Main Stator winding of Alternator Capacity more than 20 KVA and Up to 50 or 55 KVA of existing faulty Alternator of various Makes with suitable size copper enameled wire including providing insulation of appropriate class, varnishing, assembling including testing etc complete as required. 2 job maheshsol 180
68 Rewinding of Main Rotor winding of Alternator Capacity more than 20 KVA and Up to 50 or 55 KVA of existing faulty Alternator Rewinding of Main Rotor winding of Alternator Capacity more than 20 KVA and Up to 50 or 55 KVA of existing faulty Alternator of various Makes with suitable size copper enameled wire including providing insulation of appropriate class, varnishing, assembling including testing etc complete as required. 2 job maheshsol 180
69 Rewinding of Exciter Stator winding of Alternator Capacity up to 55 KVA of existing faulty Alternator Rewinding of Exciter Stator winding of Alternator Capacity up to 55 KVA of existing faulty Alternator of various Makes with suitable size copper enameled wire including providing insulation of appropriate class, varnishing, assembling including testing etc complete as required. 2 job maheshsol 180
70 Rewinding of Exciter Rotor winding of Alternator Capacity up to 55 KVA of existing faulty Alternator Rewinding of Exciter Rotor winding of Alternator Capacity up to 55 KVA of existing faulty Alternator of various Makes with suitable size copper enameled wire including providing insulation of appropriate class, varnishing, assembling including testing etc complete as required. 1 job maheshsol 180
71 Replacement or Repairing of faulty AVR for existing faulty Alternator up to 55 KVA Capacity Replacement or Repairing of faulty AVR for existing faulty Alternator upto 55 KVA Capacity iorc dismantling the faulty item, replacement by new one fixing, testing, commissioning etc. complete as reqd. 4 job maheshsol 180
72 Replacement or Repairing of faulty Power Diode for Rotating Rectifier Assembly for existing faulty Alternator up to 55 KVA Capacity Replacement or Repairing of faulty Power Diode for Rotating Rectifier Assembly for existing faulty Alternator upto 55 KVA Capacity dismantling the faulty item, replacement by new one iorc fixing, testing, commissioning etc. complete as reqd. 3 job maheshsol 180
73 Replacement or Repairing of faulty Bearing Suitable for above 20 KVA Alternator up to 55 KVA Capacity Replacement or Repairing of faulty Bearing Suitable for above 20 KVA Alternator upto 55 KVA Capacity dismantling the faulty item, replacement by new one iorc fixing, testing, commissioning etc. complete as reqd. 5 job maheshsol 180
74 Providing of 2 Core 16 Sqmm PVC insulated and PVC sheathed Aluminum conductor armored cable Providing of 2 Core 16 Sqmm PVC insulated and PVC sheathed Aluminum conductor armored cable of 1.1 KV grade confirming to relevant IS-Specification complete as reqd. Note Cable shall be provided at Site or Handed over to SSA Authority as per direction of Engg. in Charge 100 meter maheshsol 180
75 Providing of 4 Core 16 Sqmm PVC insulated and PVC sheathed Aluminum conductor armored cable Providing of 4 Core 16 Sqmm PVC insulated and PVC sheathed Aluminum conductor armored cable of 1.1 KV grade confirming to relevant IS-Specification complete as reqd. Note Cable shall be provided at Site or Handed over to SSA Authority as per direction of Engg. in Charge 300 meter maheshsol 180
76 Laying and fixing on wall Upto 35 sq. mm PVC insulated and PVC sheathed or XLPE power cable Laying and fixing of Upto 35 sq. mm ,clamped with 1mm thick saddle, one number PVC insulated and PVC sheathed or XLPE power cable of 1.1 kV grade of following size on wall surface as required. 100 meter maheshsol 180
77 Laying of direct in ground Upto 35 sq. mm PVC insulated and PVC sheathed or XLPE power cable Laying of one number up to 35 sq mm PVC insulated and PVC sheathed or XLPE power cable of 1.1 kV grade direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. 5 meter maheshsol 180
78 Laying in the existing RCC or HUMEor METAL pipe Upto 35 sq. mm PVC insulated and PVC sheathed or XLPE power cable Laying of one number up to 35 sq mm PVC insulated and PVC sheathed or XLPE power cable of 1.1 kV grade in the existing RCCor HUMEor METAL pipe etc. as required. 225 meter maheshsol 180
79 Supplying and making end termination with brass compression gland and aluminum lugs for 2 X 10 sq. mm Supplying and making end termination with brass compression gland and aluminum lugs for 2 X 10 sq. mm , 19 mm for PVC insulated and PVC sheathedorXLPE aluminum conductor cable of 1.1 kV grade as required. 8 set maheshsol 180
80 Supplying and making end termination with brass compression gland and aluminum lugs for 4 X 16 sq. mm Supplying and making end termination with brass compression gland and aluminum lugs for 4 X 16 sq. mm , 28 mm for PVC insulated and PVC sheathedorXLPE aluminum conductor cable of 1.1 kV grade as required. 24 set maheshsol 180
81 Providing and fixing 6 SWG dia G.I. wire Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surfaceor recessed conduitorsub main wiringor cable as required. 200 meter maheshsol 180
82 SITC of 32 amps four pole ON Load Side Handle operated change over switch SITC of 32 amps four pole ON Load Side Handle operated change over switch in steel enclosure capable of working 415 or 500 V iorc drilling hole on the board, making connection, earthing the body etc. as reqd. 1 each maheshsol 180
83 SITC of 63 amps 2 Pole ON Load Side Handle operated change over switch SITC of 63 amps 2 Pole ON Load Side Handle operated change over switch in steel enclosure capable of working 240 V iorc drilling hole on the board, making connection, earthing the body etc. as reqd. 1 each maheshsol 180
84 SITC of 63 amps four pole ON Load Side Handle operated change over switch SITC of 63 amps four pole ON Load Side Handle operated change over switch in steel enclosure capable of working 415 or 500 V iorc drilling hole on the board, making connection, earthing the body etc. as reqd. 3 each maheshsol 180
85 Providing and Fixing 63 A TPN Disconnector Fuse Switch Unit in sheet steel enclosure Providing and Fixing 63 A TPN Disconnector Fuse Switch Unit in sheet steel enclosure alongwith HRC fuses capable of working 415 or 500 V including drilling hole on the board, making connection, earthing the body etc. as reqd. 2 each maheshsol 180
86 Repairing of Fuel Injection Pump Repairing of Fuel Injection Pump, Nozzle and Injectors including dismantling, transportation of Pump, cleaning, repairing, testing and refitting the same on the existing EA set including replacement of faulty components etc. complete as reqd. 5 job maheshsol 180

🤖 AI-Powered Bidder Prediction

Discover companies most likely to bid on this tender

Live AI
Historical Data

Required Documents

1

Experience Criteria

2

Past Performance

3

Bidder Turnover

4

Certificate (Requested in ATC)

5

OEM Authorization Certificate

6

OEM Annual Turnover

7

Additional Doc 1 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria

8

the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer

Frequently Asked Questions

What are the eligibility requirements for **GEM/2024/B/5587208**?

The eligibility requirements include being a registered entity capable of providing the required maintenance services. Bidders must demonstrate past experience in servicing diesel engine alternator sets and submit supporting documentation to validate their qualifications.

What certificates are required for submission?

Bidders must provide various certificates including an OEM Authorization Certificate, performance reports, and documents satisfying the Auto Technical Criteria (ATC). These documents should reflect the bidder's eligibility in terms of experience and financial capability.

How can a bidder register for the tender submission?

The registration process for bidding requires interested parties to create an account on the GEM portal. Once registered, bidders must follow the instructions provided in the tender documentation to submit their proposals.

What document formats are accepted for submission?

Bidders are expected to submit their documents in standard digital formats such as PDF, DOC, or XLS, as specified in the tender guidelines. It's crucial to ensure that all documents comply with the accepted document formats mentioned.

What are the technical specifications outlined in this tender?

The technical specifications include the necessary qualifications to perform maintenance on diesel engine alternator sets, including specific tasks like component replacement and servicing. Bidders must adhere to the specified requirements as detailed in the tender documents.

What quality standards must be adhered to?

All maintenance services are expected to meet industry quality standards, ensuring reliability and efficiency. Bidders should present documentation that confirms compliance with quality norms established in the telecommunications sector.

Are there any compliance requirements?

Yes, all bidders must comply with the specifications and regulations detailed in the tender documents. Adhering to the compliance requirements ensures the integrity of the bidding process and the quality of service delivered.

What criteria are needed for testing?

The testing criteria for maintenance services include operational performance checks and component assessments that must be conducted post-maintenance to ensure efficacy and safety.

Can you explain the details of the Earnest Money Deposit (EMD)?

The Earnest Money Deposit (EMD) required for this tender is ₹11,432. This deposit acts as a security measure to affirm the bidder's serious intention to participate in the tender process.

What are the performance security requirements?

Upon securing the contract, winning bidders must provide a performance security amount, which ensures compliance with the terms of service laid out in the tender agreement.

What are the payment terms for successful bidders?

The payment terms for services rendered will be clarified during the contractual agreement following the bid selection process, ensuring timely payments for the work completed.

How is price evaluation conducted?

The price evaluation will be assessed based on the total financial proposal submitted by the bidders, alongside compliance with technical standards and requirements set forth in the tender documentation.

What submission methods are allowed?

Bidders must use the electronic submission method through the GEM portal. All necessary proposals and documents need to be uploaded as outlined in the submission methods section of the tender.

What are the key timelines for submission?

Bidders should be aware of the key timelines and deadlines as indicated in the tender documents. It's essential to adhere strictly to these deadlines to ensure successful participation.

How will the evaluation and selection process work?

The evaluation and selection process will involve a thorough review of submitted bids against established criteria, facilitating the selection of the most suitable bidder based on technical capability and financial criteria.

How will results be communicated to bidders?

Results will typically be communicated through the GEM portal or via official correspondence published by the Department of Telecommunications. Bidders should regularly check for notification of results following the evaluation process.

Are there benefits for Micro, Small, and Medium Enterprises (MSEs)?

Yes, MSEs may benefit from specific provisions and exemptions outlined within the tender documents, enhancing their capacity to compete fairly in the tendering process.

Are startups provided with any special considerations?

Startups participating in this tender may be entitled to certain advantages or exemptions regarding experience and turnover minimums, provided they submit adequate supporting documentation.

Does this tender comply with 'Make in India' policies?

This tender emphasizes local content requirements and adheres to the 'Make in India' policies, promoting domestic manufacturing and participation from local industries.

Are there any specific local content or procurement rules?

All bidders must ensure compliance with applicable local content and procurement rules as stipulated in the tender, which aim to enhance local participation and support domestic products and services.

Similar Tenders

5 found

Custom Bid for Services - Preventive Maintenance Visit Charges for DG Set along with mandatory spar

Bharat Petroleum Corporation Ltd

⏰ Deadline: 2 weeks left
🛒 Type: Service
View GEM

Custom Bid for Services - FANUC SERVICE ENGINEER VISIT CHARGES REQUIRED FOR FAULT DIAGNOSIS OF FANU

Advanced Weapons And Equipment India Limited

📍 KANPUR NAGAR, UTTAR PRADESH

⏰ Deadline: 2 weeks left
🛒 Type: Service
View GEM

Repair and Servicing of H.R. Gates of ISP Main Canal from RD 174.425 KM to RD 206 KM under ND Division No 27 Rajpur at ND E/M Sub Division no. 31 Sanawad, District Khargone including material, labour charges and testing etc. complete work.

Narmada Valley Development Authority

📍 BARWANI, MADHYA PRADESH

EMD: ₹8,793
Est: ₹4.4 L
⏰ Deadline: 2 weeks left
🛒 Type: Works
View EPROCURE

Repair and Servicing of Escape Gate (Size 5.4 m x 1.8 m x 2 Nos) of I.S.P. Canal RD 95.690 KM under ND Canal Division khargone at ND E/M Sub Division no. 31 Sanawad, District Khargone including material, labour charges and testing etc. complete work.

Narmada Valley Development Authority

📍 KHARGONE, MADHYA PRADESH

EMD: ₹5,222
Est: ₹2.6 L
⏰ Deadline: 2 weeks left
🛒 Type: Works
View EPROCURE
Urgent

Repair and Servicing of C.R. Gate (Size 5.2 m x 4.1 m x 3 Nos) of I.S.P. Canal RD 105.66 KM under ND Canal Division khargone at ND E/M Sub Division no. 31 Sanawad, District Khargone including material, labour charges and testing etc. complete work.

Narmada Valley Development Authority

📍 KHARGONE, MADHYA PRADESH

EMD: ₹7,593
Est: ₹3.8 L
⏰ Deadline: 4 days left
🛒 Type: Works
View EPROCURE