| Category | Specification | Requirement |
|---|---|---|
| PRODUCT INFORMATION | Patient Type | Adult & pediatric, Adult, Pediatric and Neonatal |
| PRODUCT INFORMATION | Type of technology | Turbine, Compressor |
| PRODUCT INFORMATION | Tidal volume in ml | (50 ml or less) to (1500 ml or more), (2 ml or less) to (1500 ml or more), (20 ml or less) to (1500 ml or more) |
| PRODUCT INFORMATION | Respiration rate, breaths/min | up to 80 or more, up to 120 or more, upto 150 or more |
| PRODUCT INFORMATION | Trigger mechanism | Pressure /flow, Both pressure and flow |
| PRODUCT INFORMATION | Inspiratory flow rate, L/min | upto 120 or more, up to 150 or more, upto 200 or more |
| PRODUCT INFORMATION | Inspiratory pressure, cm H2O | upto 50 or more, upto 80 or more |
| PRODUCT INFORMATION | IE ratio | 1:10 to 4:1, 1:6 to 3:1 |
| PRODUCT INFORMATION | Sigh breath function | Yes, No |
| PRODUCT INFORMATION | Control panel lock | Yes, No |
| PRODUCT INFORMATION | Facility for double lung ventilation | Yes, No |
| PATIENT ASSESSMENT TOOLS | Number of loops | 2 loops (P-V, F-V) with facility of saving of 1 Loops for reference, 2 loops (P-V, F-V) |
| PATIENT ASSESSMENT TOOLS | Lung recruitment tools (PV loops) / OLT (Open lung tools) | Yes, No |
| PATIENT ASSESSMENT TOOLS | Lung mechanics visualization tool | Yes, No |
| PATIENT ASSESSMENT TOOLS | Capnography/CO2 monitoring | Yes, No |
| PATIENT ASSESSMENT TOOLS | Esophageal / transpulmonary pressure monitoring | Yes, No |
| PATIENT ASSESSMENT TOOLS | APRV(Airway Pressure Release Ventilation) /Bivent/Bi level | Yes, No |
| PATIENT ASSESSMENT TOOLS | MMV(Mandatory Minute Ventilation) + PSV (Pressure Support Ventilation) /ASV( Adaptive Support Ventilation ) or ALPV(Adaptive Lung Protection Ventilation) or Automode | Yes, No |
| PATIENT ASSESSMENT TOOLS | PRVC(Pressure-Regulated Volume Control ventilation)/Auto flow | Yes, No |
| PATIENT ASSESSMENT TOOLS | High flow oxygen therapy | Yes, No |
| PATIENT ASSESSMENT TOOLS | Automatic weaning system provided | Yes, No |
| PATIENT ASSESSMENT TOOLS | Volume Support | Yes, No |
| PATIENT ASSESSMENT TOOLS | RSBI (Rapid Shallow Breathing Index) | Yes, No |
| PATIENT ASSESSMENT TOOLS | Expiratory Time constant ( Tcexp) | Yes, No |
| PATIENT ASSESSMENT TOOLS | Compliance static and/or dynamic | Yes, No |
| PATIENT ASSESSMENT TOOLS | Inspired and/or expired resistance | Yes, No |
| PATIENT ASSESSMENT TOOLS | Occlusion pressure | Yes, No |
| PATIENT ASSESSMENT TOOLS | Inspiratory and expiratory hold | Yes, No |
| PATIENT ASSESSMENT TOOLS | Spontaneous frequency | Yes, No |
| PATIENT ASSESSMENT TOOLS | Total peep, intrinsic peep, extrinsic peep | Yes, No |
| PATIENT ASSESSMENT TOOLS | Expiratory block is autoclavable and no routine calibration required | Yes, No |
| PATIENT ASSESSMENT TOOLS | Auto compensation for ET Tube | Yes, No |
| PATIENT ASSESSMENT TOOLS | Facility for automatic compliance & Leakage compensation for circuit available | Yes, No |
| PATIENT ASSESSMENT TOOLS | RS 232 out put port | Yes, No |
| PATIENT ASSESSMENT TOOLS | USB/Memory card | Yes, No |
| PATIENT ASSESSMENT TOOLS | Availability of Remote alarm/display port | Yes, No |
| PATIENT ASSESSMENT TOOLS | Facility to Report (vent alarms and patient status) | Yes, No |
| PATIENT ASSESSMENT TOOLS | HL/7 Compliant out put | Yes, No |
| PATIENT ASSESSMENT TOOLS | Type of coloured display | LED/LCD/TFT |
| PATIENT ASSESSMENT TOOLS | Display should be touch screen | Yes, No |
| PATIENT ASSESSMENT TOOLS | NIV (Non Invasive Ventilation) to be possible in all modes of ventilation available | Yes, No, NIV available in pressure targeted modes only |
| PATIENT ASSESSMENT TOOLS | Minimum Size of display (±2%) | 12, 15, 17, 18 |
| PATIENT ASSESSMENT TOOLS | Graphic display have automatic scaling facility for waves | Yes, No |
| HARDWARE AND ELECTRICAL REQUIREMENTS | Provision of UPS | Yes, No |
| HARDWARE AND ELECTRICAL REQUIREMENTS | Backup time in hrs | 1, 2, NA if not provided |
| HARDWARE AND ELECTRICAL REQUIREMENTS | Built in air source | Air compressor (external), Turbine (In built) |
| HARDWARE AND ELECTRICAL REQUIREMENTS | Availability of stand alone compressor | Yes, No |
| HARDWARE AND ELECTRICAL REQUIREMENTS | Compressor shall provide an oil free Medical air, with Peak output flow should be minimum 150 LPM and Air quality complying with ISO compressed air purity class | Yes, NA (for turbine) |
| HARDWARE AND ELECTRICAL REQUIREMENTS | Seller shall ensure compatibility of compressor with ventilator | Yes, NA (for Turbine) |
| HARDWARE AND ELECTRICAL REQUIREMENTS | Nebulizer with particle size less than 3 micron | Yes |
| ADDITIONAL ACCESSORIES | Humidifier: Servo controlled with digital monitoring of inspired gas temperature with heating wire | 1, 2, NA |
| WARRANTY | Warranty (years) | 3, 5 Or higher |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Additional Doc 1 (Requested in ATC)
Additional Doc 2 (Requested in ATC)
Additional Doc 3 (Requested in ATC)
Additional Doc 4 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Extended Deadline
15-Jan-2026, 12:00 pm
Opening Date
15-Jan-2026, 12:30 pm
Extended Deadline
09-Jan-2026, 12:00 pm
Opening Date
09-Jan-2026, 12:30 pm
N/a
📍 AHMEDABAD, GUJARAT
Sign up now to access all documents
Main Document
FINANCIAL
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS