Inverter ductable Air conditioning Unit,Refrigerent Piping,Electrical cabling,Drain Pipe,Supply Ins
Gurukula Kangri Deemed To Be University
HARIDWAR, UTTARAKHAND
Bid Publish Date
11-Jun-2026, 11:03 am
Bid End Date
02-Jul-2026, 9:00 am
EMD
₹1,30,000
Location
Progress
Quantity
1472
Category
Supply of Air Cooled Ducted 16.5 TR AC Unit
Bid Type
Two Packet Bid
Indian Navy has released a public tender for Supply of Air Cooled Ducted 16. 5 TR AC Unit, Supply of Air Cooled Ducted 5 TR AC Unit, Unloading Lifting and Shifting of 16. 5 TR Ducted package AC Unit at site, Unloading Lifting and Shifting of 5 TR Ducted package AC Unit at site, Installation N2 Pressure Testing vacummising and commissioning of 16. 5 TR AC, Installation N2 Pressure Testing vacummising and commissioning of 5 TR AC, Supply and Charging of R 410 gas, Supply and inst of floor mounted MS Stand fabricated out of MS Channel, Supply and inst of floor mounted MS Stand fabricated out of MS angel, Hard Copper Refrigerant piping between indoor and outdoor units, Supply and installation of GSS Ducting as 24G, Supply and installation of GSS Ducting as 22G, Acoustic insulation of plenum Initial ducting with 10mm thick armasound, Supply and fixing of 13mm thick Nitrile rubber Al foil faced insulation Class I, Supply and installation of AI powered Jet Nozzles with Volume control damper, Supply and inst of AI powered Return Air grills without volume control dampers, Supply and installation of GI opposed blade duct dampers, qty 1. 5 Sqmtr, Supply and fixing of canvas connection, Supply and laying of 32mm dia PVC drain piping, Electrical cabling 6 C x 1. 5 Sqmm Cu Flexible, Electrical cabling 3 C x 1. 5 Sqmm Cu Flexible, Electrical cabling 1 Sqmm Cu Flexible double Earthing in PUNE, MAHARASHTRA. Quantity: 1472. Submission Deadline: 02-07-2026 09: 00: 00. Download documents and apply online.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
Supply of Air Cooled Ducted 16.5 TR AC Unit , Supply of Air Cooled Ducted 5 TR AC Unit , Unloading Lifting and Shifting of 16.5 TR Ducted package AC Unit at site , Unloading Lifting and Shifting of 5 TR Ducted package AC Unit at site , Installation N2 Pressure Testing vacummising and commissioning of 16.5 TR AC , Installation N2 Pressure Testing vacummising and commissioning of 5 TR AC , Supply and Charging of R 410 gas , Supply and inst of floor mounted MS Stand fabricated out of MS Channel , Supply and inst of floor mounted MS Stand fabricated out of MS angel , Hard Copper Refrigerant piping between indoor and outdoor units , Supply and installation of GSS Ducting as 24G , Supply and installation of GSS Ducting as 22G , Acoustic insulation of plenum Initial ducting with 10mm thick armasound , Supply and fixing of 13mm thick Nitrile rubber Al foil faced insulation Class I , Supply and installation of AI powered Jet Nozzles with Volume control damper , Supply and inst of AI powered Return Air grills without volume control dampers , Supply and installation of GI opposed blade duct dampers, qty 1.5 Sqmtr , Supply and fixing of canvas connection , Supply and laying of 32mm dia PVC drain piping , Electrical cabling 6 C x 1.5 Sqmm Cu Flexible , Electrical cabling 3 C x 1.5 Sqmm Cu Flexible , Electrical cabling 1 Sqmm Cu Flexible double Earthing
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
OTHER
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Gurukula Kangri Deemed To Be University
HARIDWAR, UTTARAKHAND
Power Grid Corporation Of India Limited
HYDERABAD, TELANGANA
Indian Navy
Central Mine Planning And Design Institute Limited
Power Grid Corporation Of India Limited
EAST GODAVARI, ANDHRA PRADESH
Tender Results
Loading results...
Supply of Air Cooled Ducted 16.5 TR AC Unit
As per specifications and scope of work
Supply of Air Cooled Ducted 5 TR AC Unit
As per specifications and scope of work
Unloading Lifting and Shifting of 16.5 TR Ducted package AC Unit at site
As per specifications and scope of work
Unloading Lifting and Shifting of 5 TR Ducted package AC Unit at site
As per specifications and scope of work
Installation N2 Pressure Testing vacummising and commissioning of 16.5 TR AC
As per specifications and scope of work
Installation N2 Pressure Testing vacummising and commissioning of 5 TR AC
As per specifications and scope of work
Supply and Charging of R 410 gas
As per specifications and scope of work
Supply and inst of floor mounted MS Stand fabricated out of MS Channel
As per specifications and scope of work
Supply and inst of floor mounted MS Stand fabricated out of MS angel
As per specifications and scope of work
Hard Copper Refrigerant piping between indoor and outdoor units
As per specifications and scope of work
Supply and installation of GSS Ducting as 24G
As per specifications and scope of work
Supply and installation of GSS Ducting as 22G
As per specifications and scope of work
Acoustic insulation of plenum Initial ducting with 10mm thick armasound
As per specifications and scope of work
Supply and fixing of 13mm thick Nitrile rubber Al foil faced insulation Class I
As per specifications and scope of work
Supply and installation of AI powered Jet Nozzles with Volume control damper
As per specifications and scope of work
Supply and inst of AI powered Return Air grills without volume control dampers
As per specifications and scope of work
Supply and installation of GI opposed blade duct dampers, qty 1.5 Sqmtr
As per specifications and scope of work
Supply and fixing of canvas connection
As per specifications and scope of work
Supply and laying of 32mm dia PVC drain piping
As per specifications and scope of work
Electrical cabling 6 C x 1.5 Sqmm Cu Flexible
As per specifications and scope of work
Electrical cabling 3 C x 1.5 Sqmm Cu Flexible
As per specifications and scope of work
Electrical cabling 1 Sqmm Cu Flexible double Earthing
As per specifications and scope of work
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) | Price Trends |
|---|---|---|---|---|---|---|---|
| 1 | Supply of Air Cooled Ducted 16.5 TR AC Unit | As per specifications and scope of work | 2 | nos | dlogob_svj | 30 | |
| 2 | Supply of Air Cooled Ducted 5 TR AC Unit | As per specifications and scope of work | 1 | nos | dlogob_svj | 30 | |
| 3 | Unloading Lifting and Shifting of 16.5 TR Ducted package AC Unit at site | As per specifications and scope of work | 2 | nos | dlogob_svj | 30 | |
| 4 | Unloading Lifting and Shifting of 5 TR Ducted package AC Unit at site | As per specifications and scope of work | 1 | nos | dlogob_svj | 30 | |
| 5 | Installation N2 Pressure Testing vacummising and commissioning of 16.5 TR AC | As per specifications and scope of work | 2 | nos | dlogob_svj | 30 | |
| 6 | Installation N2 Pressure Testing vacummising and commissioning of 5 TR AC | As per specifications and scope of work | 2 | nos | dlogob_svj | 30 | |
| 7 | Supply and Charging of R 410 gas | As per specifications and scope of work | 45 | kg | dlogob_svj | 30 | |
| 8 | Supply and inst of floor mounted MS Stand fabricated out of MS Channel | As per specifications and scope of work | 3 | nos | dlogob_svj | 30 | |
| 9 | Supply and inst of floor mounted MS Stand fabricated out of MS angel | As per specifications and scope of work | 3 | nos | dlogob_svj | 30 | |
| 10 | Hard Copper Refrigerant piping between indoor and outdoor units | As per specifications and scope of work | 120 | rmt | dlogob_svj | 30 | |
| 11 | Supply and installation of GSS Ducting as 24G | As per specifications and scope of work | 400 | sqmtr | dlogob_svj | 30 | |
| 12 | Supply and installation of GSS Ducting as 22G | As per specifications and scope of work | 80 | sqmtr | dlogob_svj | 30 | |
| 13 | Acoustic insulation of plenum Initial ducting with 10mm thick armasound | As per specifications and scope of work | 50 | sqmtr | dlogob_svj | 30 | |
| 14 | Supply and fixing of 13mm thick Nitrile rubber Al foil faced insulation Class I | As per specifications and scope of work | 500 | sqmtr | dlogob_svj | 30 | |
| 15 | Supply and installation of AI powered Jet Nozzles with Volume control damper | As per specifications and scope of work | 45 | nos | dlogob_svj | 30 | |
| 16 | Supply and inst of AI powered Return Air grills without volume control dampers | As per specifications and scope of work | 12 | sqmtr | dlogob_svj | 30 | |
| 17 | Supply and installation of GI opposed blade duct dampers, qty 1.5 Sqmtr | As per specifications and scope of work | 1 | set | dlogob_svj | 30 | |
| 18 | Supply and fixing of canvas connection | As per specifications and scope of work | 3 | nos | dlogob_svj | 30 | |
| 19 | Supply and laying of 32mm dia PVC drain piping | As per specifications and scope of work | 20 | rmt | dlogob_svj | 30 | |
| 20 | Electrical cabling 6 C x 1.5 Sqmm Cu Flexible | As per specifications and scope of work | 30 | rmt | dlogob_svj | 30 | |
| 21 | Electrical cabling 3 C x 1.5 Sqmm Cu Flexible | As per specifications and scope of work | 50 | rmt | dlogob_svj | 30 | |
| 22 | Electrical cabling 1 Sqmm Cu Flexible double Earthing | As per specifications and scope of work | 100 | rmt | dlogob_svj | 30 |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
Additional Doc 1 (Requested in ATC)
Additional Doc 2 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Airports Authority Of India
📍 COIMBATORE, TAMIL NADU
Indian Navy
Bharat Electronics Limited (bel)
📍 GHAZIABAD, UTTAR PRADESH
Indian Army
📍 JODHPUR, RAJASTHAN
Bharat Sanchar Nigam Limited Portal(bsnl)
📍 AHMEDABAD, GUJARAT
Sign up now to access all documents
Main Document
OTHER
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS