TenderDekho Logo
GEM

Tender Notice for Digital Radiography System (V2) in INDORE, MADHYA PRADESH

Bid Publish Date

17-Feb-2026, 11:09 am

Bid End Date

10-Mar-2026, 12:00 pm

EMD

₹4,50,000

Progress

Issue17-Feb-2026, 11:09 am
AwardPending
Explore all 4 tabs to view complete tender details

Quantity

1

Bid Type

Two Packet Bid

Categories 12

A tender has been published for Employees State Insurance Corporation (esic) Digital Radiography System (V2) (Q2) in INDORE, MADHYA PRADESH. Quantity: 1 by. Submission Deadline: 10-03-2026 12: 00: 00. Check eligibility and apply.

Documents 4

GeM-Bidding-8802633.pdf

Main Document

CATALOG-Specification-1

CATALOG Specification

Buyer uploaded ATC document

ATC

GEM General Terms and Conditions Document

GEM_GENERAL_TERMS_AND_CONDITIONS

Past Similar Tenders (Historical Results)

5 found

Hospital Medical Education Mizoram Digital Radiography System Tender 2026 - IS 7620 MDR Conformity, Aizawl, 2026

Hospital Medical Education

AIZAWL, MIZORAM

Posted: 29 January 2026
Closed: 13 February 2026
GEM

Digital Radiography System (V2)

Employees State Insurance Corporation (esic)

Posted: 18 November 2024
Closed: 3 December 2024
GEM

Digital Radiography System (V2)

South Western Railway

Posted: 9 December 2024
Closed: 24 December 2024
GEM

Digital Radiography System (V2)

Health Department

ERNAKULAM, KERALA

Posted: 22 September 2025
Closed: 13 October 2025
GEM

Digital Radiography System (V2)

Ntpc Limited

BILASPUR, CHHATTISGARH

Posted: 17 February 2025
Closed: 25 March 2025
GEM

Technical Specifications 1 Item

Item #1 Details

View Catalog
Category Specification Requirement
General Product Digital Radiography System
General Description Digital Radiographic system with flat panel detector
Table and Table top parameters Type of table Floating Top Type
Table and Table top parameters Type of table movement Motorized
Table and Table top parameters Number of movements of Table 6 Way
Table and Table top parameters Longitudinal Movement (with tolerance ± 10%) ±50
Table and Table top parameters Lateral movement (with tolerance ± 10%) ±15
Table and Table top parameters Length x Width (± 5%) in cm 210 x 70
Table and Table top parameters X Ray density < 1 mm A I
Table and Table top parameters Minimum and maximum adjustable heights (± 10%) 55-85
Table and Table top parameters Load bearing capacity of table in kg 200 or more
Table Bucky System Size in inches 17x17
Table Bucky System Grid Ratios 10:1 or higher
Table Bucky System Lines in mm >=92
Upright Bucky Type Motorized
Upright Bucky Sizes in inches 17x17
Upright Bucky A E C 3 Field or higher
Upright Bucky Movable grid with Grid Ratios 10:1 or higher
Upright Bucky Line in inches >=92
Digital Detector Radiography Mode Digital
Digital Detector Number of detectors Dual
Digital Detector Detector Material Cesium Iodide
Digital Detector Detector Size in inches 17 X 17 and 17 x 17
Digital Detector Matrix size 3kx3k
Digital Detector Pixel size in µm <=175
Digital Detector DQE at 0 LP/mm 65% or more
Control panel for image acquisition Grid removable Yes
X Ray Generator and Tubes High Frequency X-ray Generator power in KW 50 KW
X Ray Generator and Tubes Maximum mA at 100 KVP 500
X Ray Generator and Tubes Heat Capacity, KHU 300-400
X Ray Generator and Tubes Control panel and X Ray tube Yes
X Ray Generator and Tubes Post Processing Features Zoom, contrast and brightness, adjustment, panning annotate, mark and reporting
Tube suspension Type of suspension Ceiling, Floor Mounted
Workstation Monitor size in inches 19, 21
Workstation DiCOM compatibility of work station Yes
Workstation Work station should be fully network ready and it should transfer images and patient data from and to hospital network using LAN connectivity or wireless LAN Yes
Workstation Work station integrated with system Yes
Workstation Work station with advance measurement tool should be provided Yes
Workstation DICOM Printing software to be provided Yes
Accessories Foot switches for adjusting longitudinal/side to side movements, locking, and light adjustment Yes
Accessories Patient fixing belts and compression device (for performing excretory urography, etc) Yes
Accessories Integration DICOM 3.0 storage SOP Classes
Accessories Lead Apron Yes
Accessories Lead Aprons - Full body and Skirt type 2 no. each (0.5pb)
Accessories Thyroid shields provided Yes, Not provided
Accessories Gonadsheet Male provided Yes, Not provided
Accessories Gonad sheet Female provided Yes, Not provided
Accessories Wall mounted stand for radiation protection aprons supplied Yes, Not provided
Accessories Lead glass window provided Yes
Accessories Footsteps for the table provided Yes
Accessories Power 440 V 50 HZ 3 Phase 16 Ampls socket
Accessories Voltage stablizer servo controlled in KVA >=50
Certifications Availability of valid Medical Device license for the product issued from the competent authority defined under Drugs and Cosmetic Act 1940 and Rules made there under as amended till date Yes
Certifications Certification for manufacturing unit ISO:13485 (Latest)
Certifications Availability of Test Report for each supplied batch/product as per Medical Device Rule (MDR) 2017 as amended till date Yes
Certifications Submission of all necessary certifications, licenses and test reports to the buyer at the time of bid submission or along with supplies as per buyer requirement Yes
Certifications AERB Type Approved Equipment Yes
Certifications Conformity to Indian Standard IS 7620- Part 1, Part 2, Part 3 Yes
Warranty Warranty in Years 5 Or higher
Miscellaneous Parameters Demonstration of equipment and training to be provided after completing supplies before acceptance Yes
Miscellaneous Parameters QA, QC and other tests as per NABH shall be carried out by OEM or authorized agency of OEM Yes
Miscellaneous Parameters Copies of all calibration and test reports to be submitted at the time of Supply of Machine Yes

🤖 AI-Powered Bidder Prediction

Discover companies most likely to bid on this tender

Live AI
Historical Data

Required Documents

1

Experience Criteria

2

Past Performance

3

Bidder Turnover

4

Certificate (Requested in ATC)

5

OEM Authorization Certificate

6

OEM Annual Turnover

7

Additional Doc 1 (Requested in ATC)

8

Additional Doc 2 (Requested in ATC)

9

Additional Doc 3 (Requested in ATC)

10

Additional Doc 4 (Requested in ATC)

11

Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria

12

the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer

Similar Tenders

3 found

Digital Radiography System (V2)

N/a

📍 ALMORA, UTTARAKHAND

EMD: ₹40,800
Est: ₹20.4 L
⏰ Deadline: 2 weeks left
🛒 Type: Goods
View GEM
Urgent

Digital Radiography System (V2)

Health Department

📍 PALAKKAD, KERALA

⏰ Deadline: 6 days left
🛒 Type: Goods
View GEM

Digital Radiography System (V2)

N/a

📍 ERNAKULAM, KERALA

EMD: ₹2.7 L
⏰ Deadline: 2 weeks left
🛒 Type: Goods
View GEM