GEM

Open Tender for High Mast Lighting Tower for large area with LED Flood Lighting System in RAIGAD, MAHARASHTRA

Bid Publish Date

24-Nov-2025, 12:58 pm

Bid End Date

15-Dec-2025, 1:00 pm

EMD

₹1,40,520

Progress

Issue24-Nov-2025, 12:58 pm
AwardPending
Explore all 4 tabs to view complete tender details

Quantity

8

Bid Type

Two Packet Bid

Categories 5

Gail India Limited has released a public tender for High Mast Lighting Tower for large area with LED Flood Lighting System (Q3) in RAIGAD, MAHARASHTRA. Quantity: 8. Submission Deadline: 15-12-2025 13: 00: 00. Download documents and apply online.

Past Similar Tenders (Historical Results)

5 found

High Mast Lighting Tower for large area with LED Flood Lighting System

Indian Army

PANCHKULA, HARYANA

Posted: 30 September 2025
Closed: 17 October 2025
GEM

High Mast Lighting Tower for large area with LED Flood Lighting System

Urban Development And Housing Department

VAISHALI, BIHAR

Posted: 19 February 2025
Closed: 6 March 2025
GEM

High Mast Lighting Tower for large area with LED Flood Lighting System

N/a

Posted: 30 October 2024
Closed: 21 November 2024
GEM

High Mast Lighting Tower for large area with LED Flood Lighting System

N/a

GORAKHPUR, UTTAR PRADESH

Posted: 8 February 2025
Closed: 22 February 2025
GEM

High Mast Lighting Tower for large area with LED Flood Lighting System

N/a

GORAKHPUR, UTTAR PRADESH

Posted: 7 February 2025
Closed: 22 February 2025
GEM

Technical Specifications 1 Item

Item #1 Details

View Catalog
Category Specification Requirement
GENERIC Height of High Mast Tower (in Meters) 16
GENERIC Installation and commissioning (Installation and commissioning work at multiple locations shall follow as per the guidelines of State/Central Govt rules and regulations as applicable) Yes. Including Civil work at site
GENERIC Onsite warranty (in Years) 2, 3, 5
High mast System No of sections 2, 3, 4, 5, 6
High mast System Effective length of each section (in m) 10, 10.5, 8.5, 5
High mast System Material construction: The mast shall be manufactured using special steel plates, conforming to 355 gradeasper BSEN10 025
High mast System Bottom diameter (in mm) - Minimum 610, 540, 570
High mast System Plate thickness for Middle (in mm) - Minimum 4
High mast System Plate thickness for Bottom (in mm) - Minimum 5, 6
High mast System No of longitudinal welds / section (in Nos) 1, 2
High mast System Diameter of base plate (in mm) - Minimum 840, 740, 770
High mast System Thickness of base plate (in mm) - Minimum 30, 25
Wind Load Maximum Wind load 50 m/sec
Door Opening Size of opening and closing door at base compartment of high mast (in mm) - Minimum 1200 x 250, 1200 x 300
Junction Box Ingress protection for Junction Box i.e. IP Class (as per IS/IEC:60529:2001 latest) Test Report from Central Government lab/NABL/ILAC accrediated lab and report shall furnish to buyer on demand IP 55, IP 65
Junction Box No of core 3, 4, 5
Junction Box Cable category FR
Junction Box Size of cable (in Sq mm) 1.5, 2.5, 4
Junction Box Conductor material shall be Copper
Winch The winch shall have provision for manual operation in case of failure of the motor Yes
Stainless Steel Wire Rope The breaking load of each rope shall be at full load as per the relevant standard >/=2400 Kg, >/=2250Kg
Electrical System, Cable and Cable Connections No. of cores 1, 2, 3, 4, 5
Electrical System, Cable and Cable Connections Cable shall be Armoured, Unarmoured
Electrical System, Cable and Cable Connections Conudctor material shall be Copper, Aluminium
Electrical System, Cable and Cable Connections Cable Category 1, C1, C2
Electrical System, Cable and Cable Connections Incoming power cable from feeder panel to base compartment of mast and cable shall conforming to IS:7098 (Part 1):1988 latest
Feeder pillar Panel Feeder pillar panel for each mast Yes, No without feeder pillar panel
Feeder pillar Panel Feeder panel shall be suitable for 415 V, 3 phase, 4 wire, 50 Hz, AC, 230 V (L-L), 3 phase, AC 50 Hz (for Mining area)for Mining sites all electricals, winch mechanism, lamps control-gears, breakers, cables etc shall be suitable for 230V(L-L), 50 Hz supply
Feeder pillar Panel The control panels shall be Stand mounted
Feeder pillar Panel Ingress protection for feeder pillar panel i.e IP Class (as per IS/IEC:60529:2001 latest).Test Report shall furnish from Central Government lab/NABL/ILAC accrediated lab to buyer on demand IP 55, IP 65, No without feeder pillar panel
Feeder pillar Panel It shall be fabricated out of 14 SWG CRCA sheet steel, No without feeder pillar panel
Feeder pillar Panel Thickness of sheet (in mm) 2, No without feeder pillar panel
Feeder pillar Panel The panels shall be given pre-treatment and powder coated and color shall be Grey, No without feeder pillar panel
Feeder pillar Panel The stand shall be painted in Black color, No without feeder pillar panel
Feeder pillar Panel Cable entry shall be at the Bottom, No without feeder pillar panel
Feeder pillar Panel The panels shall have knock outs of the required cable, No without feeder pillar panel
Feeder pillar Panel Laminated circuit diagram shall be pasted inside of the door, No without feeder pillar panel
Feeder pillar Panel Feeder pillar shall have pad locking arrangement Yes, No without feeder pillar panel
Feeder pillar Panel Earth terminal 12 mm dia. Bolts, No without feeder pillar panel
Feeder pillar Panel Panel shall have a sloping cover to avoid accumulation of dust Yes, No without feeder pillar panel
Feeder pillar Panel Panel shall be provided with incoming & outgoing MCCB / MCB of appropriate rating and in desired quantity depending on total no of circuits in use yes, No without feeder pillar panel
Feeder pillar Panel Timer for automatic ON & OFF of lights with pilot lamps shall be provided Yes, No without feeder pillar panel
Feeder pillar Panel Bus bars material Yes. Copper, No without feeder pillar panel
Feeder pillar Panel No of Cores 1, 2, 3, 4, 5, No without feeder pillar panel
Feeder pillar Panel Size of cable (in Sq.mm) 1.5, 2.5, 4, 6, 10, 16, No without feeder pillar panel
Feeder pillar Panel Cable Shall be Armoured, Unarmoured, No without feeder pillar panel
Feeder pillar Panel The conductor material shall be Copper, Aluminium, No without feeder pillar panel
Feeder pillar Panel cable category 1, C1, C2, No without feeder pillar panel
LED FLOOD LIGHT LUMINAIRE No. of Luminaires for each high mast lighting tower (in Nos) 4, 6, 8, 10, 12, 16, 18
LED FLOOD LIGHT LUMINAIRE LED Rating/System Wattage/Rated Power for each luminaire 100W, 110W, 120W, 125W, 130W, 140W, 150W, 180W, 200W, 250W, 300W, 350W, 400W, 500W, 1000W
LED FLOOD LIGHT LUMINAIRE Luminaire System Efficacy (Lumen/watt) >/= 100 Lm/Watt
LED FLOOD LIGHT LUMINAIRE Ingress Protection (IP Rating) as per IS:10322 (Part 1):1982 latest IP65, IP66
LED FLOOD LIGHT LUMINAIRE Mounting brackets (included) Adjustable
LED FLOOD LIGHT LUMINAIRE Input operating Voltage range and frequency 90 to 300 Volts AC at 50Hz+/-2Hz, 140 to 270 Volts AC at 50 Hz+/-2 Hz with auto cutt off at below 120V
LED FLOOD LIGHT LUMINAIRE Rated voltage 230 V AC 50 Hz, 415+/-10% V AC 50 Hz +/-5%
LED FLOOD LIGHT LUMINAIRE Colour temperature 6000K (+/- 500K), 5000K (+/- 500K), 4000K (+/- 500K), 3000K (+/- 500K)
LED FLOOD LIGHT LUMINAIRE Optic lense material (UV stabilised) (Write NA for without optic lense supply) Poly carbonate lense, NA
LED FLOOD LIGHT LUMINAIRE Operating temperature range -20 deg C to +50 deg C, -10 deg C to +50 deg C, -10 deg C to +55 deg C
LED FLOOD LIGHT LUMINAIRE The luminaire shall be protected against surges and transients( Internal) >/=5KV, >/=4KV
LED FLOOD LIGHT LUMINAIRE Number of electronic control gear per luminaire (power supplies) 1 No., 2 Nos., 3 Nos., 4 Nos.
LED FLOOD LIGHT LUMINAIRE Length of ISI marked three core wire (shall be provided along with supply of material) 50 cm, 100 cm

🤖 AI-Powered Bidder Prediction

Discover companies most likely to bid on this tender

Live AI
Historical Data

Required Documents

1

Experience Criteria

2

Additional Doc 1 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria

3

the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer

Similar Tenders

5 found
Urgent

High Mast Lighting Tower for large area with LED Flood Lighting System

Rural Development Department

📍 SAMASTIPUR, BIHAR

⏰ Deadline: 7 days left
🛒 Type: Goods
View GEM
Urgent

High Mast Lighting Tower for large area with LED Flood Lighting System

Rural Development Department

📍 SAMASTIPUR, BIHAR

⏰ Deadline: 7 days left
🛒 Type: Goods
View GEM
Urgent

High Mast Lighting Tower for large area with LED Flood Lighting System

Rural Development Department

📍 SAMASTIPUR, BIHAR

⏰ Deadline: 7 days left
🛒 Type: Goods
View GEM
Urgent

Bishrampur Nagar Panchayat High Mast Lighting Tower with LED Flood Lighting System Tender Jharkhand 2025

Bishrampur Nagar Panchayat

📍 PALAMAU, JHARKHAND

⏰ Deadline: 3 days left
🛒 Type: Goods
View GEM
Urgent

Begusarai District Panchayats High Mast Lighting Tower with LED Flood Lighting System Tender 2025 Bihar

Begusarai District Panchayats

📍 BEGUSARAI, BIHAR

⏰ Deadline: 1 day left
🛒 Type: Goods
View GEM