Solar Power Plant (Roof Top) for ONGRID System, Single Phase,Solar Power Plant (Roof Top) for ONGRI
District Panchayat Anand
Bid Publish Date
25-May-2026, 5:14 pm
Bid End Date
09-Jun-2026, 3:00 pm
EMD
₹58,806
Value
₹58,80,600
Location
Progress
Quantity
52
Category
Solar Power Plant (Roof Top) for ONGRID System, Single Phase
Bid Type
Two Packet Bid
State Bank Of India (sbi) has released a public tender for Solar Power Plant (Roof Top) for ONGRID System, Single Phase (Q3) in PUNE, MAHARASHTRA. Quantity: 52. Submission Deadline: 09-06-2026 15: 00: 00. Download documents and apply online.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
Solar Power Plant (Roof Top) for ONGRID System, Single Phase (Q3)
Trusted by 5,000+ companies to find, track, and win government tenders.
Our team will walk you through the platform and help set up your profile — free, no commitment.
Our team will reach out to schedule your free session.
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
District Panchayat Anand
Chandrapur District Panchayats
CHANDRAPUR, MAHARASHTRA
N/a
THANE, MAHARASHTRA
N/a
PUNE, MAHARASHTRA
N/a
CHANDRAPUR, MAHARASHTRA
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| GENERIC | A Grid Tied Photo Voltaic (SPV) power plant consists of | SPV array, Module Mounting Structure, Power Conditioning Unit (PCU) consisting of Maximum Power Point Tracker (MPPT), Inverter, and Controls and Protections, interconnect cables and switches |
| GENERIC | PV Array Mounting | Mounted on a suitable structure |
| GENERIC | Grid Tied SPV System | Without battery and designed with necessary features to supplement the grid power during day time. |
| INVERTER | Rated output power of inverter (in KW) | 2 |
| INVERTER | Switching device | IGBT |
| INVERTER | Number of Phase | 1 |
| INVERTER | Inverter output wave form | Pure sine wave |
| INVERTER | Number of MPPT per inverter | 1 |
| INVERTER | Number of string at input side of inverter ( input port +ve and -ve) ( hint: 1 sets contains 1 +ve and 1 -ve port) | 1 set |
| INVERTER | Maximum power point tracker | Integrated in the PCU/inverter to maximize energy drawn from the array |
| INVERTER | Operating Voltage Range of Inverter | 100 V to 500 V |
| INVERTER | Over load support at Input side, DC | 15% of Maximum Input Voltage |
| INVERTER | Maximum input current for each MPPT (in Ampere) | 11 |
| INVERTER | Service condition | Outdoor |
| INVERTER | Ingress protection rating of inverter | IP 65 (for outdoor use) |
| INVERTER | Cooling medium for inverter | Intelligent fan cooling |
| INVERTER | Manual switch for disconnecting DC supply | Yes |
| INVERTER | Inverter mounting type | Wall Mounted |
| INVERTER OUTPUT | Maximum current for single phase inverter (in Ampere) | 10.5 |
| INVERTER OUTPUT | Output voltage (in Volt) | 240 V |
| INVERTER OUTPUT | Invert auto trip at output side | Lower : at 160 V, Higher : at 285 V with adjustable |
| INVERTER OUTPUT | Overall Efficiency (in %) | >96 |
| PROTECTION FOR INVERTER | Overlod protection | 110% for 1 Minute,, 125% for 30 sec.,, 150% for 5 sec. |
| PROTECTION FOR INVERTER | Over temperature protection | Yes at 65 Deg. C Cooling Fan will auto switch ON |
| PROTECTION FOR INVERTER | Surge protection | Metal Oxide Varistor (MOV) |
| PROTECTION FOR INVERTER | Insulation Resistance Monitoring | Yes |
| PROTECTION FOR INVERTER | Grid monitoring protection | Yes |
| PROTECTION FOR INVERTER | Inverter body material | M.S. Plate |
| SERVICE CONDITION | Operating temperature | -25 to +60 deg. C |
| DISPLAY FEATURES ON INVERTER | Type of display | LED |
| DISPLAY FEATURES ON INVERTER | Display parameters [Hint: Products matching all selected values will be displayed; For example, if both 'Power Factor' and 'DC Current' are selected, product that include both options will be shown] | DC Voltage, DC Current, AC Voltage, AC Current, Out put frequency, Power Factor |
| DISPLAY FEATURES ON INVERTER | Generating power data storage facility | Yes for 2 Years from the date of commissioning |
| DISPLAY FEATURES ON INVERTER | Interface facility for transmitting the generating power data for cloud storage | Inbuilt Wifi Enabled |
| DISPLAY FEATURES ON INVERTER | Net meter | Approved by Government of India/State Government authority concerned for connecting to Grid |
| DC DISTRIBUTION BOARD | DC Distribution panel to receive the DC output from the array field | Yes with surge arrestors |
| DC DISTRIBUTION BOARD | Ingress protection (Enclosure protection) of DC Distribution Box | IP65 |
| DC DISTRIBUTION BOARD | Material of bus bar and size | Copper, size as per inverter rating |
| DC DISTRIBUTION BOARD | Circuit Breaker for input side (DC side) for each inverter | MCB 15 A |
| CABLE FOR INPUT | ISI Marked Connecting Cables According to Inverter Rating for Each System | PV Module to Inverter DC |
| CABLE FOR INPUT | Electric Cable for Input | 1C x 6 Sq. mm, Copper Cable (as per IS:694:2010 latest) |
| CABLE FOR INPUT | Cable Length for PV Module to Inverter, DC (in meter) | 5 |
| AC DISTRIBUTION BOARD | AC Distribution Panel Board (DPB) for controlling the AC power from PCU/Inverter | 1 Phase 230 Volt +/- 10%, 50 HZ +/-3% |
| AC DISTRIBUTION BOARD | Panel construction | Metal clad, totally enclosed, floor mounted, air insulated, cubical type with change over switch |
| AC DISTRIBUTION BOARD | Ingress protection (Enclosure protection) of AC Distribution Box | IP65 for outdoor |
| AC DISTRIBUTION BOARD | Panels designed for minimum expected ambient temperature | 45 deg. C |
| AC DISTRIBUTION BOARD | Circuit Breaker for output side (AC side) for each inverter | MCB 16 A |
| CABLE FOR OUTPUT | ISI Marked Connecting Cables according to Inverter rating for each system | From Inverter to Net Meter and to mains at LT Bus bar while in grid tied mode |
| CABLE FOR OUTPUT | Size and Conformity of the specification for cable | 2C x 10 Sq. mm, Copper Cable (as per IS:694:2010 latest) |
| Other Add on Items | Cabling work at input side for each system | With PVC Conduit pipe with necessary clamps and screws |
| Other Add on Items | Cabling work at output side for each system | With Cable Tray with fitment accessories |
| Other Add on Items | Danger boards and signages | 1 No. |
| ARRAY STRUCTURE | Material of mounting structure | Structural Steel, Grade: E300 (as per IS:2062:2011 latest) |
| JUNCTION BOX | Material of Junction Box | GRP( Glass reinforced plastic) |
| WIND LOAD | Mounting Structure - Designed to withstand wind speeds of the site’s designated wind zone | Yes |
| WIND LOAD | Compliance to wind velocity test for the Mounting structure of PV System | as per IS 875:1987 part 3 latest |
| WARRANTY | Minimum Guarantee - Maintenance of Peak Output Watt Capacity | > / = 90% at the end of 10 years and >/= 80% at the end of 25 years |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
Additional Doc 1 (Requested in ATC)
Additional Doc 2 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Rajasthan Wild Life Jaipur
📍 ALWAR, RAJASTHAN
Raisen District Panchayats
📍 RAISEN, MADHYA PRADESH
East Central Railway
📍 HAZARIBAG, JHARKHAND
Panchayat Samiti Daund
📍 PUNE, MAHARASHTRA
Latur District Panchayats
📍 LATUR, MAHARASHTRA
Sign up now to access all documents
Main Document
CATALOG Specification
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS