Gas Chromatography
Directorate Of Forensic Science
Bid Publish Date
23-Feb-2026, 5:02 pm
Bid End Date
06-Mar-2026, 6:00 pm
EMD
₹19,620
Progress
Quantity
1
Bid Type
Two Packet Bid
Organization: Harcourt Butler Technological Institute. Product: Gas Chromatograph (GC) configuration package including detectors, injectors, capillary and packed columns, auto sampler compatibility, head space options, pyrolyzer compatibility, software, and electrical safety compliance. Estimated value not disclosed; EMD: ₹19,620. Location: Uttar Pradesh. The scope emphasizes inclusive detectors, portable equipment, and multiple detector configurations with flexible supply terms. A notable differentiator is the breadth of GC accessory integration—auto sampler, head space, and pyrolyzer compatibility are explicitly requested. The tender prioritizes safety and compliance with central government/ILAC-approved test reports. The document highlights mandatory certifications and on-site installation/training obligations. This procurement supports advanced GC capabilities for research or education labs.
Experience in supplying GC configurations with detectors and autosampler systems
Demonstrated NABL/ILAC-compliant test reports for GC equipment
Manufacturer/OEM authorization for GC components and detectors
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Directorate Of Forensic Science
Agharkar Research Institute (ari)
PUNE, MAHARASHTRA
Agharkar Research Institute (ari)
PUNE, MAHARASHTRA
University Of Kashmir
SRINAGAR, JAMMU & KASHMIR
N/a
PONDICHERRY, PUDUCHERRY
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "GC Detectors inclusive in the scope of supply (Select Only those Detectors, which are part of supply)" | Flame Ionization Detector (FID), Thermal Conductivity Detector (TCD or Hot Wire Detector) |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of FID in the System - inclusive in the scope of Supply (Select '0' if this Detector is not a part of supply)" | 1 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of TCD in the System - inclusive in the scope of Supply (Select '0' if this Detector is not a part of supply)" | 1 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of ECD in the System - inclusive in the scope of Supply (Select '0' if this Detector is not a part of supply)" | 0 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of NPD/FTD in the System - inclusive in the scope of Supply (Select '0' if this Detector is not a part of supply)" | 0 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of FPD in the System - inclusive in the scope of Supply (Select '0' if this Detector is not a part of supply)" | 0 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of PID in the System - inclusive in the scope of Supply (Select '0' if this Detector is not a part of supply)" | 0 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of PFPD in the System - inclusive in the scope of Supply (Select '0' if this Detector is not a part of supply)" | 0 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | Number of Inlets GC can Simultaneously Support | 3 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | Number of Detectors (Ports) GC can Simultaneously Support | 3 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | Number of Capillary Columns provided in GC - inclusive in the scope of Supply | 2 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | Type of Capillary Column | Semi-Polar |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "GC Capillary Column Length (Hint:-Select '0' if Not Applicable)" | 30.0 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of Packed Columns provided in GC - inclusive in the scope of Supply (Hint:-Select '0' if Not Applicable)" | 2 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "GC Packed Column Length (Hint:-Select '0' if Not Applicable)" | 9.0 |
| PERFORMANCE | "GC Detector Minimum Detection Level (MDL) " | < 3.0 pg C/s for FID < 400 pg/ml for TCD |
| COLUMN OVEN (GAS CHROMATOGRAPH - GC) | Maximum Operating Temperature (GC Oven) | upto 400 deg. C, upto 450 deg. C (2) Or higher |
| COLUMN OVEN (GAS CHROMATOGRAPH - GC) | Number of Oven Ramps / Plateaus for Temperature programming | 9/10 or more |
| COLUMN OVEN (GAS CHROMATOGRAPH - GC) | Temperature Ramp Rate - Maximum | 50 Deg. C/minute or better |
| PNEUMATIC CONTROL | Number of Injection Ports | 2 |
| PNEUMATIC CONTROL | Maximum Injection Port heating Temperature | upto 400 deg. C (1), upto 450 deg. C (2) Or higher |
| PNEUMATIC CONTROL | Pressure Range | upto100 psi (1), upto 120 psi (2) Or higher |
| PNEUMATIC CONTROL | Pressure set point Resolution (±)(psi) | 0.001, 0.01, 0.1 Or lower |
| PNEUMATIC CONTROL | Type of Sample Injection Port | split / Splitless, Purged packed Inlet |
| PNEUMATIC CONTROL | Split Ratio | NA |
| AUTO INJECTOR / AUTO SAMPLER | Compatible Liquid Auto Sampler - inclusive in the scope of supply | No |
| AUTO INJECTOR / AUTO SAMPLER | Capacity of the Liquid Auto Sampler (Number of Vials) | 0, 15, 100, 150 Or higher |
| AUTO INJECTOR / AUTO SAMPLER | Number of Injection Ports in the Liquid Auto Sampler | 0 |
| AUTO INJECTOR / AUTO SAMPLER | Number of Channels in the Liquid Auto Sampler | 0 |
| AUTO INJECTOR / AUTO SAMPLER | Minimum Volume of the injected liquid sample | 0.0 |
| AUTO INJECTOR / AUTO SAMPLER | Maximum Volume of the injected liquid sample | 0.0 |
| AUTO INJECTOR / AUTO SAMPLER | "Liquid Auto Sampler Features (Select applicable features Only)" | NA |
| HEAD SPACE SAMPLER | Compatible Head Space Sampler- inclusive in the scope of supply | No |
| HEAD SPACE SAMPLER | Capacity of the Head Space Sampler Carousel (number of Vials) | NA |
| HEAD SPACE SAMPLER | Head Space Sampler Temperature Range | NA |
| PYROLYZER SYSTEM | Compatible Pyrolyzer System for pyrolysis of solid and liquid samples- inclusive in the scope of supply | No |
| SALIENT FEATURES OF GAS CHROMATOGRAPH (GC) | "Salient Featutes of GC (Select applicable features Only)" | Over Heat Protection |
| SOFTWARE | "Software Features (Select Applicable Features only)" | Compatible with Windows 7 or higher version operating system |
| GENERIC | Display | Built-in Display |
| GENERIC | Connectivity interface | USB |
| GENERIC | Provision to split the sample from single injection to two different detectors and get results for two detectors simultaneously | No |
| ACESSORIES | Gas Supply inclusive in the scope of supply | Hydrogen, Argon, Zero Air |
| ACESSORIES | Capacity of Gas cylinder | 47 liters water capacity |
| ACESSORIES | Number of Cyliners of each type supplied - inclusive in the scope of supply | 1 |
| ACESSORIES | Gas cylinders certified by PESO | Yes |
| ACESSORIES | Regulator - inclusive in the scope of supply | Dual Stage Regulator |
| ACESSORIES | "Other Accessories inclusive in the scope of supply (Select only those Accessories which are part of supply)" | Gas purification panel for all Gases with moisture trap, Syringe for manual injection x 05 nos, Graphite ferrules x 10 nos, Septa for injector x 100 nos, O-rings x 10 nos. of each type, Tool Kit x 1 no., User / Technical / Maintenance Manual |
| ENVIRONMENTAL | Minimum Operating Temperature | 0.0 - 8.0 Or lower |
| ENVIRONMENTAL | Maximum Operating Temperature | 45.0 - 65.0 Or higher |
| ENVIRONMENTAL | Operating Humidity (RH) (%) at 40 degree C | 85.0 - 95.0 Or higher |
| INSTALLATION & COMMISSIONING / WARRANTY / AVAILABILITY OF SPARES / TRAINING | Warranty on equipment | 1.0 |
| INSTALLATION & COMMISSIONING / WARRANTY / AVAILABILITY OF SPARES / TRAINING | Number of days onsite training provided | 3.0 |
| CERTIFICATION / TEST REPORT | "Availability of UL/CE Certificate as per IEC 61010- 1 latest - Safety requirements for electrical equipment for measurement,control, and laboratory use General requirements" | No |
| CERTIFICATION / TEST REPORT | Conformance to EMC/EMI as per IEC 61326-1 latest - Electrical equipment for measurement, control and laboratory use | No |
| CERTIFICATION / TEST REPORT | Availability of Test Reports from Central Govt / NABL approved / ILAC accredited Lab to prove conformity to the specification | No |
Discover companies most likely to bid on this tender
GST registration certificate
Permanent Account Number (PAN) card
Experience certificates of GC systems supply
Financial statements or turnover proof
EMD payment receipt (₹19,620) or bank guarantee
Technical bid documents detailing GC configuration
OEM authorization letters for GC components
Safety certification evidence (UL/CE per IEC 61010-1, EMC/EMI IEC 61326-1)
Test reports from NABL/ILAC accredited labs
Warranty and on-site training plan
Bidders must submit GST, PAN, experience certificates, financials, and EMD of ₹19,620. Include OEM authorizations and NABL/ILAC lab test reports; provide detailed GC configuration with detector counts, column types, auto sampler compatibility, and safety certifications (UL/CE per IEC 61010-1, IEC 61326-1).
Required documents include GST certificate, PAN, experience certificates, financial statements, EMD proof, OEM authorizations, technical compliance details, and NABL/ILAC test reports proving conformance to standards and safety certifications for GC equipment.
Specifications require detectors included in scope with explicit counts (FID, TCD, ECD, NPD/FTD, FPD, PID, PFPD) and number of capillary and packed columns, column length, capillary type, and oven temperature/ramp details; auto sampler compatibility and sample injection parameters must be specified.
The EMD amount is ₹19,620; submit with the bid as part of the proposal package via online payment or approved bank instrument, ensuring it remains valid through evaluation and contract awarding per tender terms.
Equipment must comply with UL/CE per IEC 61010-1 and EMC/EMI IEC 61326-1; provide NABL/ILAC accredited test reports; ensure conformity with central government testing standards before installation.
An option clause allows ±25% quantity variation; delivery period adjusts using the formula (Increased quantity ÷ Original quantity) × Original delivery period, with a minimum extension of 30 days; extended delivery terms depend on contract execution.
Bidders must provide on-site installation and specify the number of training days; training should cover GC operation, software usage, detector maintenance, and safety procedures; warranty terms and spare parts availability are tied to the installation package.
Provide test reports from NABL-approved or ILAC-accredited laboratories validating GC configuration, detectors, and accessories against specified performance metrics and safety standards; attach these reports to the technical bid.
Council Of Scientific And Industrial Research (csir)
📍 DEHRADUN, UTTARAKHAND
Food Safety And Drug Administration
📍 VARANASI, UTTAR PRADESH
National Institute Of Technology (nit)
Sign up now to access all documents
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS