Handheld Digital Infrared Thermometer
Central Railway
Bid Publish Date
14-Jul-2026, 1:50 pm
Bid End Date
29-Jul-2026, 2:00 pm
Location
Progress
Quantity
70
Bid Type
Two Packet Bid
Public procurement opportunity for N/a Handheld Digital Infrared Thermometer (Q3) in TIRUNELVELI, TAMIL NADU. Quantity: 70 issued by. Submission Deadline: 29-07-2026 14: 00: 00. View full details and respond.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
Handheld Digital Infrared Thermometer (Q3)
Advisory Bank
State Bank of India
ePBG Percentage
5%
ePBG Duration (Months)
3
Payment Timelines
Payments shall be made to the Seller within 10 days of issue of consignee receipt-cum-acceptance certificate (CRAC) and on-line submission of bills (This is in supersession of 10 days time as provided in clause 12 of GeM GTC)
Max Delivery Days
15
Delivery Locations
1
Delivery Cities
Tirunelveli
Delivery Pincodes
627108
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| Rajam | 627108,Nanguneri Panchayat Union , Thisayanvillai Road, Near Railway Gate, Tholkappiyanagar, Nanguneri - 627108 | Tirunelveli | Tamil Nadu | 627108 | 70 | 15 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
OTHER
GEM_GENERAL_TERMS_AND_CONDITIONS
Central Railway
Indian Space Research Organization
BANGALORE, KARNATAKA
South Central Railway
KRISHNA, ANDHRA PRADESH
Nuclear Power Corporation Of India Limited
TIRUNELVELI, TAMIL NADU
North Central Railway
ALLAHABAD, UTTAR PRADESH
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| PERFORMANCE (INFRARED / NON-CONTACT) | Lowest Measurable Temperature (Infrared Non-contact) | -70, -60, -50, -40, -35, -33, -32, -30, -25, -20, -18, -10, 0, 30, 40, 50, 100, 200, 300, 400, 500, 600, 700, 800, 900 Or lower |
| PERFORMANCE (INFRARED / NON-CONTACT) | Highest Measurable Temperature (Infrared Non-contact) | 40, 50, 100, 150, 200, 220, 250, 260, 275, 300, 350, 360, 380, 400, 450, 500, 535, 550, 600, 650, 700, 750, 760, 800, 900, 950, 1000, 1050, 1100, 1200, 1300, 1370, 1400, 1470, 1500, 1600, 1700, 1800, 1850, 1900, 2000, 2100, 2200, 2300, 2400, 2500, 2600, 2700, 2800, 2900, 3000 Or higher |
| PERFORMANCE (INFRARED / NON-CONTACT) | Display Resolution | 0.1, 0.2, 0.5, 1 Or lower |
| PERFORMANCE (INFRARED / NON-CONTACT) | Basic Accuracy (±) | 0.5, 0.75, 1, 1.5, 2, 2.5, 3, 5 Or lower |
| PERFORMANCE (INFRARED / NON-CONTACT) | Emissivity (W/m2) | Continuously Adjustable from 0.1 to 1.00, Fixed at 0.95, > 0.95 |
| DISPLAY / DATA OUTPUT | Type of Display | LCD, LED, OLED |
| DISPLAY / DATA OUTPUT | Back-light display | Yes, No |
| DISPLAY / DATA OUTPUT | Display Size(in inch) | 2.0 to 2.4, 2.5 to 2.9, 3.0 to 3.4, 3.5 to 3.9, 4.0 to 4.4, 4.5 to 4.9, 5.0 to 5.4, 5.5 to 5.9, 6.0 to 6.4, 6.5 to 6.9 Or higher |
| DISPLAY / DATA OUTPUT | Data Output to other devices | Yes, No |
| DISPLAY / DATA OUTPUT | Data point logging capability (on board memory) | 0, 10, 12, 20, 30, 40, 50, 100, 200, 500, 1000, 2000, 3000, 4000, 4999 Or higher |
| BATTERY | Power Source | Rechargeable Battery |
| BATTERY | Battery Size, if Non Rechargeable Battery | AAA, Type-C |
| BATTERY | Battery Chemistry | Li-ion, Alkaline |
| SALIENT FEATURES / FUNCTIONS | Salient Features / Functions | Datahold, Data Recall, Integral Tripod Mount, Built-In Laser Sighting, Fahrenheit and Celsius Conversion, Hazardous location approval, Date and Time Stamping, High and Low audible alarm, Low Battery indication, Trigger lock for continuous monitoring, Maximum and Minimum Reading, Average and Differential reading, Integrated thermocouple Input for contact Measurement |
| ACCESSORIES | Standard accessories inclusive in the scope of supply | Data output cabkle, Data transfer software, Battery Charger, Adhesive Tape Roll, Belt Holder, Wrist Strap, Neck Strap, Carrying Case, Instruction booklet, User Manual, Air Probe-T/C Type K, Food Probe-T/C Type K, Immersion Tip-T/C Type K, Immersion/Penetration Probe-T/C Type K, Thermocouple with TC adapter-T/C Type K, RTD Sensor, Calibration Points, Emissivity Reference Chart |
| GENERIC | Built-in laser for precisely aiming the target | Yes, No |
| GENERIC | Laser Class | Class I, Class II, NA |
| GENERIC | Laser sighting | Single-point laser, Dual laser, Three dot laser, NA |
| GENERIC | Optional/User Guide/Manual | Yes, No |
| OPERATING CONDITIONS / INGRESS PROTECTION | Minimum Operating Temperature | 0, -5, -10, -15, -20, -25, -30 Or lower |
| OPERATING CONDITIONS / INGRESS PROTECTION | Maximum Operating Temperature | 50, 55, 60, 65, 70 Or higher |
| OPERATING CONDITIONS / INGRESS PROTECTION | Maximum Operating Humidity at 40 deg C - Non-condensing (Rh) | 65, 70, 75, 80, 85, 90, 95 Or higher |
| WARRANTY | Warranty | 1, 2, 3, 4, 5 |
| CERTIFICATION / TEST REPORTS | Hazardous location (Intrinsically Safe / non-incendive) approval | Yes, No |
| CERTIFICATION / TEST REPORTS | Availability of Test Reports from Central Govt / NABL approved / ILAC accredited Lab to prove conformity to the specification | Yes, No |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Additional Doc 1 (Requested in ATC)
Additional Doc 2 (Requested in ATC)
Additional Doc 3 (Requested in ATC)
Additional Doc 4 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Indian Oil Corporation Limited
Office Of Dg (ace)
📍 CHENNAI, TAMIL NADU
Uranium Corporation Of India Limited
📍 EAST SINGHBHUM, JHARKHAND
Office Of Dg (mss)
📍 PANCHKULA, HARYANA
Indian Space Research Organization
📍 THIRUVANANTHAPURAM, KERALA
Sign up now to access all documents
Main Document
CATALOG Specification
OTHER
GEM_GENERAL_TERMS_AND_CONDITIONS