DEPTH VERNIER CALIPER
Bangalore Metro Rail Corporation Limited
BANGALORE, KARNATAKA
Bid Publish Date
25-Jul-2025, 11:23 am
Bid End Date
16-Aug-2025, 11:00 am
EMD
₹38,910
Location
Progress
Quantity
113
Public procurement opportunity for Nuclear Power Corporation Of India Limited 1. Vernier - Dial type Calipers Display Calipers. External Measurement Range-mm. 0-150 Least Count in UTTARA KANNADA, KARNATAKA. Quantity: 113 issued by. Submission Deadline: 16-08-2025 11: 00: 00. View full details and respond.
Main Document
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Bangalore Metro Rail Corporation Limited
BANGALORE, KARNATAKA
Tender Results
Loading results...
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) |
|---|---|---|---|---|---|---|
| 1 | 1. Vernier - Dial type Calipers Display Calipers. External Measurement Range-mm. 0-150 Least Count - Resolution 0.01 millimeter | Vernier / Dial type Calipers Display Calipers. External Measurement Range (mm) 0-150 Least Count / Resolution 0.01 millimeter | 3 | nos | dm_mm_kgs | 180 |
| 2 | 2. Vernier - Dial type Calipers Display Calipers. External Measurement Range -mm. 0-300 Least Count - Resolution 0.02 millimeter | Vernier / Dial type Calipers Display Calipers. External Measurement Range (mm) 0-300 Least Count / Resolution 0.02 millimeter | 3 | nos | dm_mm_kgs | 180 |
| 3 | 3. Outside Micrometer i. Range-- 0- 25 mm, ii. Least Count--- 0.01 mm. iii. Accuracy---- Plus-Minus 0.002 mm. | Outside Micrometer i) Range-- 0- 25 mm, ii) Least Count--- 0.01 mm. iii) Accuracy---- Plus/Minus 0.002 mm. | 3 | nos | dm_mm_kgs | 180 |
| 4 | 4. Outside Micrometer, i. Range-- 25-50 mm, ii. Least Count--- 0.01 mm. iii. Accuracy---- Plus-Minus 0.002 mm. | Outside Micrometer, i) Range-- 25-50 mm, ii) Least Count--- 0.01 mm. iii) Accuracy---- Plus/Minus 0.002 mm. | 4 | nos | dm_mm_kgs | 180 |
| 5 | 5. Outside Micrometer, i. Range-- 50-75 mm, ii. Least Count--- 0.01 mm. iii. Accuracy---- Plus-Minus 0.002 mm. | Outside Micrometer, i) Range-- 50-75 mm, ii) Least Count--- 0.01 mm. iii) Accuracy---- Plus/Minus 0.002 mm. | 4 | nos | dm_mm_kgs | 180 |
| 6 | 6. Outside Micrometer, i. Range-- 75-100 mm, ii. Least Count--- 0.01 mm. iii. Accuracy---- Plus-Minus 0.003 mm. | Outside Micrometer, i) Range-- 75-100 mm, ii) Least Count--- 0.01 mm. iii) Accuracy---- Plus/Minus 0.003 mm. | 3 | nos | dm_mm_kgs | 180 |
| 7 | 7. Outside Micrometer, i. Range-- 100-125 mm, ii. Least Count--- 0.01 mm. iii. Accuracy---- Plus-Minus 0.003 mm. | Outside Micrometer, i) Range-- 100-125 mm, ii) Least Count--- 0.01 mm. iii) Accuracy---- Plus/Minus 0.003 mm. | 3 | nos | dm_mm_kgs | 180 |
| 8 | 8. Outside Micrometer, i. Range-- 125-150 mm, ii. Least Count--- 0.01 mm. iii. Accuracy---- Plus-Minus 0.003 mm. | Outside Micrometer, i) Range-- 125-150 mm, ii) Least Count--- 0.01 mm. iii) Accuracy---- Plus/Minus 0.003 mm. | 3 | nos | dm_mm_kgs | 180 |
| 9 | 9. Outside Micrometer, i. Range-- 150-175 mm, ii. Least Count--- 0.01 mm. iii. Accuracy---- Plus-Minus 0.004 mm. | Outside Micrometer, i) Range-- 150-175 mm, ii) Least Count--- 0.01 mm. iii) Accuracy---- Plus/Minus 0.004 mm. | 3 | nos | dm_mm_kgs | 180 |
| 10 | 10. Outside Micrometer, i. Range-- 200-300 mm, ii. Least Count--- 0.01 mm. | Outside Micrometer, i) Range-- 200-300 mm, ii) Least Count--- 0.01 mm. | 2 | nos | dm_mm_kgs | 180 |
| 11 | 11. Outside Micrometer, i. Range-- 300-400 mm, ii. Least Count--- 0.01 mm. | Outside Micrometer, i) Range-- 300-400 mm, ii) Least Count--- 0.01 mm. | 2 | nos | dm_mm_kgs | 180 |
| 12 | 12. Outside Micrometer, i. Range-- 400-500 mm, ii. Least Count--- 0.01 mm. | Outside Micrometer, i) Range-- 400-500 mm, ii) Least Count--- 0.01 mm. | 2 | nos | dm_mm_kgs | 180 |
| 13 | 13. Outside Micrometer, i. Range-- 500-600 mm, ii. Least Count--- 0.01 mm. | Outside Micrometer, i) Range-- 500-600 mm, ii) Least Count--- 0.01 mm. | 2 | nos | dm_mm_kgs | 180 |
| 14 | 14. Outside Micrometer, i. Range-- 600-700 mm, ii. Least Count--- 0.01 mm. | Outside Micrometer, i) Range-- 600-700 mm, ii) Least Count--- 0.01 mm. | 1 | nos | dm_mm_kgs | 180 |
| 15 | 15. Inside Micrometer, i. Range-- 5-30 mm, ii. Least Count--- 0.01 mm. iii. Accuracy---- Plus-Minus 0.005 mm. | Inside Micrometer, i) Range-- 5-30 mm, ii) Least Count--- 0.01 mm. iii) Accuracy---- Plus/Minus 0.005 mm. | 2 | nos | dm_mm_kgs | 180 |
| 16 | 16. Inside Micrometer, i. Range-- 25-50 mm, ii. Least Count--- 0.01 mm. iii. Accuracy---- Plus-Minus 0.006 mm. | Inside Micrometer, i) Range-- 25-50 mm, ii) Least Count--- 0.01 mm. iii) Accuracy---- Plus/Minus 0.006 mm. | 2 | nos | dm_mm_kgs | 180 |
| 17 | 17. Tubular Inside Micrometer, Plain Face., i. Range-- 50-150 mm, ii. Least Count--- 0.01 mm. | Tubular Inside Micrometer (Plain Face), i) Range-- 50-150 mm, ii) Least Count--- 0.01 mm. | 3 | nos | dm_mm_kgs | 180 |
| 18 | 18. Tubular Inside Micrometer, Plain Face., i. Range-- 50-300 mm, ii. Least Count--- 0.01 mm. | Tubular Inside Micrometer (Plain Face), i) Range-- 50-300 mm, ii) Least Count--- 0.01 mm. | 3 | nos | dm_mm_kgs | 180 |
| 19 | 19. Tubular Inside Micrometer, Plain Face., i. Range-- 50-500 mm, ii. Least Count--- 0.01 mm. | Tubular Inside Micrometer (Plain Face), i) Range-- 50-500 mm, ii) Least Count--- 0.01 mm. | 2 | nos | dm_mm_kgs | 180 |
| 20 | 20. Tubular Inside Micrometer, Plain Face., i. Range-- 50-1000 mm, ii. Least Count--- 0.01 mm. | Tubular Inside Micrometer (Plain Face), i) Range-- 50-1000 mm, ii) Least Count--- 0.01 mm. | 2 | nos | dm_mm_kgs | 180 |
| 21 | 21. Depth Micrometer, i. Range-- 0-150mm, ii. Least Count--- 0.01 mm. | Depth Micrometer, i) Range-- 0-150mm, ii) Least Count--- 0.01 mm. | 2 | nos | dm_mm_kgs | 180 |
| 22 | 22. Depth Micrometer, i. Range-- 0-300mm, ii. Least Count--- 0.01 mm. | Depth Micrometer, i) Range-- 0-300mm, ii) Least Count--- 0.01 mm. | 2 | nos | dm_mm_kgs | 180 |
| 23 | 23. Vernier Depth Gauge, with fine adjustment, i. Range-- 0-150mm, ii. Least Count--- 0.02 mm. iii. Accuracy --- Plus-Minus0.03 mm. | Vernier Depth Gauge, with fine adjustment, i) Range-- 0-150mm, ii) Least Count--- 0.02 mm. iii) Accuracy --- Plus/Minus0.03 mm. | 5 | nos | dm_mm_kgs | 180 |
| 24 | 24. Vernier Depth Gauge, with fine adjustment, i. Range-- 0-300 mm, ii. Least Count--- 0.02 mm. iii. Accuracy --- Plus-Minus0.04 mm. | Vernier Depth Gauge, with fine adjustment, i) Range-- 0-300 mm, ii) Least Count--- 0.02 mm. iii) Accuracy --- Plus/Minus0.04 mm. | 3 | nos | dm_mm_kgs | 180 |
| 25 | 25. Vernier Depth Gauge, with fine adjustment, i. Range-- 0-600mm, ii. Least Count--- 0.02 mm. iii. Accuracy --- Plus-Minus0.05 mm. | Vernier Depth Gauge, with fine adjustment, i) Range-- 0-600mm, ii) Least Count--- 0.02 mm. iii) Accuracy --- Plus/Minus0.05 mm. | 2 | nos | dm_mm_kgs | 180 |
| 26 | 26. Vernier Caliper, i. Range-- 0-150mm-6 Inch, ii. Least Count--- 0.02-.001 Inch mm. iii. Accuracy --- Plus-Minus0.03 mm. | Vernier Caliper, i) Range-- 0-150mm/6 Inch, ii) Least Count--- 0.02/.001 Inch mm. iii) Accuracy --- Plus/Minus0.03 mm. | 4 | nos | dm_mm_kgs | 180 |
| 27 | 27. Vernier Caliper, i. Range-- 0-200mm-8 Inch, ii. Least Count--- 0.02 mm-.001 Inch. iii. Accuracy --- Plus-Minus0.03 mm. | Vernier Caliper, i) Range-- 0-200mm/8 Inch, ii) Least Count--- 0.02 mm/.001 Inch. iii) Accuracy --- Plus/Minus0.03 mm. | 3 | nos | dm_mm_kgs | 180 |
| 28 | 28. Vernier Caliper, i. Range-- 0-300 mm-12 Inch, ii. Least Count--- 0.02 mm-.001 Inch. iii. Accuracy --- Plus-Minus0.04 mm. | Vernier Caliper, i) Range-- 0-300 mm/12 Inch, ii) Least Count--- 0.02 mm/.001 Inch. iii) Accuracy --- Plus/Minus0.04 mm. | 3 | nos | dm_mm_kgs | 180 |
| 29 | 29. Universal Bevel Protractor, Least Count--- 5 min. 0-90-0.. | Universal Bevel Protractor, Least Count--- 5 min.(0-90-0). | 1 | nos | dm_mm_kgs | 180 |
| 30 | 30. Precision Level, i. Size - 200X44X38.2 mm. ii. Least Count--- 0.02mm-m. | Precision Level, i) Size - 200X44X38.2 mm. ii) Least Count--- 0.02mm/m. | 2 | nos | dm_mm_kgs | 180 |
| 31 | 31. Telescopic Gauge Set, i. Range--- 8-150 mm. | Telescopic Gauge Set, i) Range--- 8-150 mm. | 3 | nos | dm_mm_kgs | 180 |
| 32 | 32. Dial Indicator, i. Range--- 10 mm. ii. Least Count----0.01 mm. | Dial Indicator, i) Range--- 10 mm. ii) Least Count----0.01 mm. | 4 | nos | dm_mm_kgs | 180 |
| 33 | 33. Magnetic Stand with swivel clamps and fittings for conventional Dial Gauge mounting Range Dia. 4-8 mm. | Magnetic Stand with swivel clamps & fittings for conventional Dial Gauge mounting Range Dia. 4-8 mm. | 4 | nos | dm_mm_kgs | 180 |
| 34 | 34. Pitch Gauge, Unified Pitch Gauge Set. Range -0.4 to 7.0 mm- 4-42 TPI Resolution -51 Leaves. | Pitch Gauge (Unified Pitch Gauge Set) Range -0.4 to 7.0 mm/ 4-42 TPI Resolution -51 Leaves. | 4 | nos | dm_mm_kgs | 180 |
| 35 | 35. Dial Indicator Range-0-5mm Least count-0.01mm. | Dial Indicator Range-0-5mm Least count-0.01mm. | 3 | nos | dm_mm_kgs | 180 |
| 36 | 36. Inside Micrometer, Plain Face. Range-50-200 mm Least count-0.01mm | Inside Micrometer (Plain Face) Range-50-200 mm Least count-0.01mm | 5 | nos | dm_mm_kgs | 180 |
| 37 | 37. Vernier Depth Gage without fine adjustment Range-0-150mm Least count-0.02mm | Vernier Depth Gage without fine adjustment Range-0-150mm Least count-0.02mm | 3 | nos | dm_mm_kgs | 180 |
| 38 | 38. Dial test Indicator, Horizontal Type. Range-0-0.8mm Least count-0.01mm | Dial test Indicator (Horizontal Type) Range-0-0.8mm Least count-0.01mm | 4 | nos | dm_mm_kgs | 180 |
| 39 | 39. Telescoping Gauge Set Range-8-150mm | Telescoping Gauge Set Range-8-150mm | 4 | nos | dm_mm_kgs | 180 |
Discover companies most likely to bid on this tender
Sign up now to access all documents
Main Document
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS