BSNL DOT Compressor & Electrical Spares Tender North 24 Parganas West Bengal 2026 with 25% Quantity Flexibility
Bharat Sanchar Nigam Limited Portal(bsnl)
NORTH 24 PARGANAS, WEST BENGAL
Bid Publish Date
08-Jun-2026, 12:31 pm
Bid End Date
18-Jun-2026, 2:00 pm
EMD
₹28,048
Value
₹14,02,403
Location
Progress
Quantity
3789
Category
Comprehensive Mntc
Bid Type
Two Packet Bid
Bharat Sanchar Nigam Limited Portal(bsnl) invites bids for Comprehensive Mntc, Fault attending, Compressor, Motor, Blade Indoor, Blade Outdoor, Capacitor, Relay, Thermostal, Contactor, MCB, PCB, Timer, Gas in NORTH 24 PARGANAS, WEST BENGAL. Quantity: 3789. Submission Deadline: 18-06-2026 14: 00: 00. Submit your proposal before the deadline.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
Comprehensive Mntc , Fault attending , Compressor , Motor , Blade Indoor , Blade Outdoor , Capacitor , Relay , Thermostal , Contactor , MCB , PCB , Timer , Gas
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
BOQ
BOQ
GEM_GENERAL_TERMS_AND_CONDITIONS
Bharat Sanchar Nigam Limited Portal(bsnl)
NORTH 24 PARGANAS, WEST BENGAL
Director General Telecom Hq
Bharat Sanchar Nigam Limited Portal(bsnl)
PATNA, BIHAR
Indian Army
Eastern Coalfields Limited
BARDHAMAN, WEST BENGAL
Tender Results
Loading results...
Comprehensive Mntc
Comprehensive maintenance of Inverter/Non-Inverter type 1.5 TR Split /Window AC unit and its associated power feeding arrangement including replacement of faulty spares, charging of refrigerant, replacement of faulty condenser motor and blower motor, replacement of faulty compressor, cleaning of filter, cooling coil and condenser coil etc. for smooth operation of the AC units as detailed in work specification /methodology attached complete as reqd. a) 1.5 TR capacity Split /Window AC units (149 nos. AC units/month for 24 Months)
Fault attending
Attending initial faults of existing 1.5 TR Split /window AC units i/c supplying & fixing of following compatible spare parts for different make of AC units (Inverter/Non-Inverter) available at sites complete with testing, commissioning as required to make the faulty AC unit in satisfactory healthy condition. a) Fixed speed Compressor (1.5 TR) for AC unit
Compressor
b) Variable speed Compressor (1.5 TR) for AC unit
Motor
c) Single Phase Blower fan motor for 1.5 TR AC unit.
Blade Indoor
d) Single Phase Condenser fan motor for 1.5 TR AC unit.
Blade Outdoor
e) Indoor unit Fan Blade
Capacitor
f) Outdoor unit Fan Blade
Capacitor
g) Starting Capacitor suitable for compressor unit.
Capacitor
h) Running Capacitor suitable for compressor unit.
Capacitor
i) Blower Motor Capacitor.
Relay
j) Condenser Motor Capacitor.
Thermostal
k) Starting Relay
Contactor
l) Thermostat
MCB
m) 2-Pole , 25Amp Power Contactor (MNX 25 or similar) For AC controller Unit
MCB
n) DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V C curve DP MCB.
MCB
o) 25A DP MCB
MCB
p) 5-32A SPMCB
PCB
q) PCB (Control card for Inverter AC unit)
Timer
r) Cyclic Timer (Selec 800Xc - Din Rail or similar suitable)
Gas
Supplying & charging of suitable fresh refrigerant gas in the existing inverter/non-inverter 1.5 TR Split / Window Air-Conditioner i/c necessary leak testing, fault rectification, brazing etc with pressure testing etc. complete as required.
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) | Price Trends |
|---|---|---|---|---|---|---|---|
| 1 | Comprehensive Mntc | Comprehensive maintenance of Inverter/Non-Inverter type 1.5 TR Split /Window AC unit and its associated power feeding arrangement including replacement of faulty spares, charging of refrigerant, replacement of faulty condenser motor and blower motor, replacement of faulty compressor, cleaning of filter, cooling coil and condenser coil etc. for smooth operation of the AC units as detailed in work specification /methodology attached complete as reqd. a) 1.5 TR capacity Split /Window AC units (149 nos. AC units/month for 24 Months) | 3,576 | jobs | sdeesdxv | 730 | |
| 2 | Fault attending | Attending initial faults of existing 1.5 TR Split /window AC units i/c supplying & fixing of following compatible spare parts for different make of AC units (Inverter/Non-Inverter) available at sites complete with testing, commissioning as required to make the faulty AC unit in satisfactory healthy condition. a) Fixed speed Compressor (1.5 TR) for AC unit | 7 | nos | sdeesdxv | 730 | |
| 3 | Compressor | b) Variable speed Compressor (1.5 TR) for AC unit | 7 | nos | sdeesdxv | 730 | |
| 4 | Motor | c) Single Phase Blower fan motor for 1.5 TR AC unit. | 7 | nos | sdeesdxv | 730 | |
| 5 | Blade Indoor | d) Single Phase Condenser fan motor for 1.5 TR AC unit. | 7 | nos | sdeesdxv | 730 | |
| 6 | Blade Outdoor | e) Indoor unit Fan Blade | 7 | nos | sdeesdxv | 730 | |
| 7 | Capacitor | f) Outdoor unit Fan Blade | 7 | nos | sdeesdxv | 730 | |
| 8 | Capacitor | g) Starting Capacitor suitable for compressor unit. | 15 | nos | sdeesdxv | 730 | |
| 9 | Capacitor | h) Running Capacitor suitable for compressor unit. | 15 | nos | sdeesdxv | 730 | |
| 10 | Capacitor | i) Blower Motor Capacitor. | 15 | nos | sdeesdxv | 730 | |
| 11 | Relay | j) Condenser Motor Capacitor. | 15 | nos | sdeesdxv | 730 | |
| 12 | Thermostal | k) Starting Relay | 15 | nos | sdeesdxv | 730 | |
| 13 | Contactor | l) Thermostat | 15 | nos | sdeesdxv | 730 | |
| 14 | MCB | m) 2-Pole , 25Amp Power Contactor (MNX 25 or similar) For AC controller Unit | 15 | nos | sdeesdxv | 730 | |
| 15 | MCB | n) DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V C curve DP MCB. | 7 | nos | sdeesdxv | 730 | |
| 16 | MCB | o) 25A DP MCB | 7 | nos | sdeesdxv | 730 | |
| 17 | MCB | p) 5-32A SPMCB | 15 | nos | sdeesdxv | 730 | |
| 18 | PCB | q) PCB (Control card for Inverter AC unit) | 15 | nos | sdeesdxv | 730 | |
| 19 | Timer | r) Cyclic Timer (Selec 800Xc - Din Rail or similar suitable) | 7 | nos | sdeesdxv | 730 | |
| 20 | Gas | Supplying & charging of suitable fresh refrigerant gas in the existing inverter/non-inverter 1.5 TR Split / Window Air-Conditioner i/c necessary leak testing, fault rectification, brazing etc with pressure testing etc. complete as required. | 15 | job | sdeesdxv | 730 |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Additional Doc 1 (Requested in ATC)
Additional Doc 2 (Requested in ATC)
Additional Doc 3 (Requested in ATC)
Additional Doc 4 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Indian Army
📍 SAGAR, MADHYA PRADESH
Security Printing And Minting Corporation Of India Limited (spmcil)
📍 NASHIK, MAHARASHTRA
Uttar Pradesh Rajya Vidyut Utpadan Nigam Limited (uprvunl) Lucknow
📍 SONBHADRA, UTTAR PRADESH
Combined Admission System (cas), Department Of Medical Health & Family Welfare, Uttar Pradesh
📍 MATHURA, UTTAR PRADESH
Indian Army
📍 JAMMU, JAMMU & KASHMIR
Sign up now to access all documents
Main Document
BOQ
BOQ
GEM_GENERAL_TERMS_AND_CONDITIONS