Machining Components 1,Machining Components 2,Machining Components 3,Machining Components 4,Machini
Marketing Division
NASHIK, MAHARASHTRA
Bid Publish Date
22-Jun-2026, 10:08 am
Bid End Date
11-Jul-2026, 11:00 am
EMD
₹303
Value
₹5,60,000
Location
Progress
Quantity
2277
Category
Mechanical Fabrication 1
Bid Type
Two Packet Bid
A tender has been published for N/a Mechanical Fabrication 1, Mechanical Fabrication 2, Mechanical Fabrication 3, Mechanical Fabrication 4, Mechanical Fabrication 5, Mechanical Fabrication 6, Mechanical Fabrication 7, Mechanical Fabrication 8, Mechanical Fabrication 9, Mechanical Fabrication 10, Mechanical Fabrication 11, Mechanical Fabrication 12, Mechanical Fabrication 13, Mechanical Fabrication 14, Mechanical Fabrication 15, Mechanical Fabrication 16, Mechanical Fabrication 17, Mechanical Fabrication 18, Mechanical Fabrication 19, Mechanical Fabrication 20, Mechanical Fabrication 21, Mechanical Fabrication 22, Mechanical Fabrication 23, Mechanical Fabrication 24, Mechanical Fabrication 25, Mechanical Fabrication 26, Mechanical Fabrication 27, Mechanical Fabrication 28, Mechanical Fabrication 29, Mechanical Fabrication 30, Mechanical Fabrication 31, Mechanical Fabrication 32, Mechanical Fabrication 33 in BIJNOR, UTTAR PRADESH. Quantity: 2277 by. Submission Deadline: 11-07-2026 11: 00: 00. Check eligibility and apply.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
Mechanical Fabrication 1 , Mechanical Fabrication 2 , Mechanical Fabrication 3 , Mechanical Fabrication 4 , Mechanical Fabrication 5 , Mechanical Fabrication 6 , Mechanical Fabrication 7 , Mechanical Fabrication 8 , Mechanical Fabrication 9 , Mechanical Fabrication 10 , Mechanical Fabrication 11 , Mechanical Fabrication 12 , Mechanical Fabrication 13 , Mechanical Fabrication 14 , Mechanical Fabrication 15 , Mechanical Fabrication 16 , Mechanical Fabrication 17 , Mechanical Fabrication 18 , Mechanical Fabrication 19 , Mechanical Fabrication 20 , Mechanical Fabrication 21 , Mechanical Fabrication 22 , Mechanical Fabrication 23 , Mechanical Fabrication 24 , Mechanical Fabrication 25 , Mechanical Fabrication 26 , Mechanical Fabrication 27 , Mechanical Fabrication 28 , Mechanical Fabrication 29 , Mechanical Fabrication 30 , Mechanical Fabrication 31 , Mechanical Fabrication 32 , Mechanical Fabrication 33
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
BOQ
BOQ
GEM_GENERAL_TERMS_AND_CONDITIONS
Marketing Division
NASHIK, MAHARASHTRA
N/A
SANGAREDDY, TELANGANA
N/A
SANGAREDDY, TELANGANA
Council Of Scientific And Industrial Research (csir)
BANGALORE, KARNATAKA
Bharat Heavy Electricals Limited
SANGAREDDY, TELANGANA
Tender Results
Loading results...
Mechanical Fabrication 1
Dismantling and removal of damaged Distributor fitted on Pan shifting scrap to scrap yard fabrication of new Distributor from 8/10 mm thick MS plate erection strengthening and satisfactory trial run complete
Mechanical Fabrication 2
Dismantling of damaged B Vacuum Crystallizer (45 Ton Capacity) installed on Pan Floor shifting scrap to scrap yard fabrication from 12 mm thick MS plate erection at original position replacement of damaged shaft channels angles and ribs welding leak proof testing and satisfactory trial Size 7m 30 centimeter Length X 2 m 80cm Dia
Mechanical Fabrication 3
Dismantling and replacement of damaged cell of Juice Weighing Tank (Round Tank) fabrication from 8/10 mm thick MS plate reconnection of all associated fittings and leak proof trial Size Height 1 m 35 cm Dia 2 m 66 cm Channel Size 200 mm
Mechanical Fabrication 4
Removal of damaged section pipe of Raw Juice Pump and installation of new section pipe including all associated connections and leak proof testing
Mechanical Fabrication 5
Dismantling of damaged 10 inch Raw Juice Pump Header and fabrication/installation of new Header including all associated connections and leak proof testing
Mechanical Fabrication 6
Dismantling and replacement of damaged cell of Raw Juice Receiving Tank with 8/10 mm thick MS plate including leak proof trial Size Dia 3 m 5 cm X Height 3 m
Mechanical Fabrication 7
Dismantling and replacement of damaged shell and partition plate of Heavy Molasses Receiving Tank fabrication from 8/10 mm thick MS plate installation and leak proof testing Partition Plate Size Dia 3 m X Length 3 m 4 cm Bottom Shell Size 2950 mm X 4450 mm
Mechanical Fabrication 8
Dismantling and replacement of damaged shell and partition plate of Light Molasses Receiving Tank fabrication from 8/10 mm thick MS plate installation and leak proof testing Partition Plate Size Dia 3 m X Length 3 m 4 cm Bottom Shell Size 2950 mm X 4450 mm
Mechanical Fabrication 9
Dismantling of Heavy/Light Filtrate Juice Tank mounted on Small Vacuum Filter and fabrication of new tank from 10 mm thick MS plate including nipples flanges pipe connections and trial run Approx Size Dia 1 m X Height 1m 5c m
Mechanical Fabrication 10
Dismantling of Heavy/Light Filtrate Juice Tank mounted on Large Vacuum Filter and fabrication of new tank from 10 mm thick MS plate including nipples flanges pipe connections and trial run Approx Size Dia 1 m 5 cm X Height 1 m
Mechanical Fabrication 11
Replacement of damaged Seval and Umbrella portions in Vapor Cell 950 Sq M and Old Quad Body No 4 including fabrication erection and trial Size 2 m X 2 m
Mechanical Fabrication 12
Replacement of damaged Seval and Umbrella portions in New Quad Body No 1 and 2 including fabrication erection and trial Size 1 m X 1m 5 cm
Mechanical Fabrication 13
Dismantling of damaged Catcher of Pan fabrication of new Catcher from 8/10 mm thick MS plate installation with eliminator vapor pipe and trial run Size Dia 1m 5 cm X Height 2m 5 cm
Mechanical Fabrication 14
Opening of blinds in Spray System pipeline replacement of damaged nozzles/clusters cleaning re fixing blinds and satisfactory trial
Mechanical Fabrication 15
Dismantling and removal of damaged 8 inch PVC pipeline and stacking at designated place
Mechanical Fabrication 16
Supply and installation of new 8 inch PVC pipeline complete
Mechanical Fabrication 17
Dismantling and removal of damaged 6 inch PVC pipeline and stacking at designated place
Mechanical Fabrication 18
Supply and installation of new 6 inch PVC pipeline complete
Mechanical Fabrication 19
Dismantling of damaged Tee portion installed above Pan No 6 disposal of scrap fabrication and installation of new Tee from 8/10 mm thick MS plate and satisfactory trial Size Dia 1120 mm X Length 3700 mm
Mechanical Fabrication 20
Repair/replacement of corroded platform of Pan Station Condenser and Crystallizer using MS plates complete
Mechanical Fabrication 21
Dismantling of damaged Dome Plate of Pan No 1 & 6 and fabrication/installation of new Dome Plate from 8/10 mm thick MS plate Size Dia 3 m 10 cm X Length 80 cm
Mechanical Fabrication 22
Dismantling of damaged bends and reducers of Injection and Spray Pump section pipeline cleaning of flanges fabrication and installation of new bends/reducers including welding and trial
Mechanical Fabrication 23
Dismantling of damaged Spray Pond Header (Dia 750 mm 650 mm 550 mm 475 mm & 385 mm) including nipples flanges and bends and shifting scrap to scrap yard
Mechanical Fabrication 24
Fabrication and installation of Spray Pond Header (Dia 750 mm 650 mm 550 mm 475 mm & 385 mm) from 8/10 mm thick MS plate including branch pipe connections and trial
Mechanical Fabrication 25
Dismantling of damaged Injection Header Dia 500 mm and disposal of scrap
Mechanical Fabrication 26
Fabrication and installation of Injection Header Dia 500 mm from 8/10 mm thick MS plate including all pipe connections and satisfactory trial
Mechanical Fabrication 27
Dismantling of damaged 10 inch pipeline from Condenser to Injection Header and installation of new 10 inch pipeline complete
Mechanical Fabrication 28
Fabrication and installation of 6 inch nipple in Condensate Tank Pump Delivery Line
Mechanical Fabrication 29
Fabrication and installation of 6 inch flange in Condensate Tank Pump Delivery Line
Mechanical Fabrication 30
Dismantling and re installation of 6 inch pipeline in Condensate Tank Pump Delivery Line
Mechanical Fabrication 31
Replacement of damaged 6 inch bypass pipeline of Melter including installation and satisfactory trial
Mechanical Fabrication 32
Fabrication and installation of 6 inch bend for Melter bypass line
Mechanical Fabrication 33
Fabrication and installation of 6 inch flange for Melter bypass line
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) | Price Trends |
|---|---|---|---|---|---|---|---|
| 1 | Mechanical Fabrication 1 | Dismantling and removal of damaged Distributor fitted on Pan shifting scrap to scrap yard fabrication of new Distributor from 8/10 mm thick MS plate erection strengthening and satisfactory trial run complete | 2 | each | buyer10.cdgvvdup.up | 90 | |
| 2 | Mechanical Fabrication 2 | Dismantling of damaged B Vacuum Crystallizer (45 Ton Capacity) installed on Pan Floor shifting scrap to scrap yard fabrication from 12 mm thick MS plate erection at original position replacement of damaged shaft channels angles and ribs welding leak proof testing and satisfactory trial Size 7m 30 centimeter Length X 2 m 80cm Dia | 1 | job | buyer10.cdgvvdup.up | 90 | |
| 3 | Mechanical Fabrication 3 | Dismantling and replacement of damaged cell of Juice Weighing Tank (Round Tank) fabrication from 8/10 mm thick MS plate reconnection of all associated fittings and leak proof trial Size Height 1 m 35 cm Dia 2 m 66 cm Channel Size 200 mm | 1 | job | buyer10.cdgvvdup.up | 90 | |
| 4 | Mechanical Fabrication 4 | Removal of damaged section pipe of Raw Juice Pump and installation of new section pipe including all associated connections and leak proof testing | 10 | running meter | buyer10.cdgvvdup.up | 90 | |
| 5 | Mechanical Fabrication 5 | Dismantling of damaged 10 inch Raw Juice Pump Header and fabrication/installation of new Header including all associated connections and leak proof testing | 1 | each header | buyer10.cdgvvdup.up | 90 | |
| 6 | Mechanical Fabrication 6 | Dismantling and replacement of damaged cell of Raw Juice Receiving Tank with 8/10 mm thick MS plate including leak proof trial Size Dia 3 m 5 cm X Height 3 m | 1 | job | buyer10.cdgvvdup.up | 90 | |
| 7 | Mechanical Fabrication 7 | Dismantling and replacement of damaged shell and partition plate of Heavy Molasses Receiving Tank fabrication from 8/10 mm thick MS plate installation and leak proof testing Partition Plate Size Dia 3 m X Length 3 m 4 cm Bottom Shell Size 2950 mm X 4450 mm | 3 | each | buyer10.cdgvvdup.up | 90 | |
| 8 | Mechanical Fabrication 8 | Dismantling and replacement of damaged shell and partition plate of Light Molasses Receiving Tank fabrication from 8/10 mm thick MS plate installation and leak proof testing Partition Plate Size Dia 3 m X Length 3 m 4 cm Bottom Shell Size 2950 mm X 4450 mm | 2 | each | buyer10.cdgvvdup.up | 90 | |
| 9 | Mechanical Fabrication 9 | Dismantling of Heavy/Light Filtrate Juice Tank mounted on Small Vacuum Filter and fabrication of new tank from 10 mm thick MS plate including nipples flanges pipe connections and trial run Approx Size Dia 1 m X Height 1m 5c m | 2 | each | buyer10.cdgvvdup.up | 90 | |
| 10 | Mechanical Fabrication 10 | Dismantling of Heavy/Light Filtrate Juice Tank mounted on Large Vacuum Filter and fabrication of new tank from 10 mm thick MS plate including nipples flanges pipe connections and trial run Approx Size Dia 1 m 5 cm X Height 1 m | 2 | each | buyer10.cdgvvdup.up | 90 | |
| 11 | Mechanical Fabrication 11 | Replacement of damaged Seval and Umbrella portions in Vapor Cell 950 Sq M and Old Quad Body No 4 including fabrication erection and trial Size 2 m X 2 m | 2 | each | buyer10.cdgvvdup.up | 90 | |
| 12 | Mechanical Fabrication 12 | Replacement of damaged Seval and Umbrella portions in New Quad Body No 1 and 2 including fabrication erection and trial Size 1 m X 1m 5 cm | 2 | each | buyer10.cdgvvdup.up | 90 | |
| 13 | Mechanical Fabrication 13 | Dismantling of damaged Catcher of Pan fabrication of new Catcher from 8/10 mm thick MS plate installation with eliminator vapor pipe and trial run Size Dia 1m 5 cm X Height 2m 5 cm | 1 | each | buyer10.cdgvvdup.up | 90 | |
| 14 | Mechanical Fabrication 14 | Opening of blinds in Spray System pipeline replacement of damaged nozzles/clusters cleaning re fixing blinds and satisfactory trial | 30 | each | buyer10.cdgvvdup.up | 90 | |
| 15 | Mechanical Fabrication 15 | Dismantling and removal of damaged 8 inch PVC pipeline and stacking at designated place | 108 | running meter | buyer10.cdgvvdup.up | 90 | |
| 16 | Mechanical Fabrication 16 | Supply and installation of new 8 inch PVC pipeline complete | 108 | running meter | buyer10.cdgvvdup.up | 90 | |
| 17 | Mechanical Fabrication 17 | Dismantling and removal of damaged 6 inch PVC pipeline and stacking at designated place | 60 | running meter | buyer10.cdgvvdup.up | 90 | |
| 18 | Mechanical Fabrication 18 | Supply and installation of new 6 inch PVC pipeline complete | 60 | running meter | buyer10.cdgvvdup.up | 90 | |
| 19 | Mechanical Fabrication 19 | Dismantling of damaged Tee portion installed above Pan No 6 disposal of scrap fabrication and installation of new Tee from 8/10 mm thick MS plate and satisfactory trial Size Dia 1120 mm X Length 3700 mm | 1 | each | buyer10.cdgvvdup.up | 90 | |
| 20 | Mechanical Fabrication 20 | Repair/replacement of corroded platform of Pan Station Condenser and Crystallizer using MS plates complete | 30 | sq mtr | buyer10.cdgvvdup.up | 90 | |
| 21 | Mechanical Fabrication 21 | Dismantling of damaged Dome Plate of Pan No 1 & 6 and fabrication/installation of new Dome Plate from 8/10 mm thick MS plate Size Dia 3 m 10 cm X Length 80 cm | 2 | each | buyer10.cdgvvdup.up | 90 | |
| 22 | Mechanical Fabrication 22 | Dismantling of damaged bends and reducers of Injection and Spray Pump section pipeline cleaning of flanges fabrication and installation of new bends/reducers including welding and trial | 2 | each | buyer10.cdgvvdup.up | 90 | |
| 23 | Mechanical Fabrication 23 | Dismantling of damaged Spray Pond Header (Dia 750 mm 650 mm 550 mm 475 mm & 385 mm) including nipples flanges and bends and shifting scrap to scrap yard | 1 | mt | buyer10.cdgvvdup.up | 90 | |
| 24 | Mechanical Fabrication 24 | Fabrication and installation of Spray Pond Header (Dia 750 mm 650 mm 550 mm 475 mm & 385 mm) from 8/10 mm thick MS plate including branch pipe connections and trial | 2 | mt | buyer10.cdgvvdup.up | 90 | |
| 25 | Mechanical Fabrication 25 | Dismantling of damaged Injection Header Dia 500 mm and disposal of scrap | 600 | kg | buyer10.cdgvvdup.up | 90 | |
| 26 | Mechanical Fabrication 26 | Fabrication and installation of Injection Header Dia 500 mm from 8/10 mm thick MS plate including all pipe connections and satisfactory trial | 1,200 | kg | buyer10.cdgvvdup.up | 90 | |
| 27 | Mechanical Fabrication 27 | Dismantling of damaged 10 inch pipeline from Condenser to Injection Header and installation of new 10 inch pipeline complete | 10 | running meter | buyer10.cdgvvdup.up | 90 | |
| 28 | Mechanical Fabrication 28 | Fabrication and installation of 6 inch nipple in Condensate Tank Pump Delivery Line | 2 | no | buyer10.cdgvvdup.up | 90 | |
| 29 | Mechanical Fabrication 29 | Fabrication and installation of 6 inch flange in Condensate Tank Pump Delivery Line | 4 | no | buyer10.cdgvvdup.up | 90 | |
| 30 | Mechanical Fabrication 30 | Dismantling and re installation of 6 inch pipeline in Condensate Tank Pump Delivery Line | 6 | running meter | buyer10.cdgvvdup.up | 90 | |
| 31 | Mechanical Fabrication 31 | Replacement of damaged 6 inch bypass pipeline of Melter including installation and satisfactory trial | 12 | running meter | buyer10.cdgvvdup.up | 90 | |
| 32 | Mechanical Fabrication 32 | Fabrication and installation of 6 inch bend for Melter bypass line | 4 | no | buyer10.cdgvvdup.up | 90 | |
| 33 | Mechanical Fabrication 33 | Fabrication and installation of 6 inch flange for Melter bypass line | 5 | no | buyer10.cdgvvdup.up | 90 |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Extended Deadline
11-Jul-2026, 11:00 am
Opening Date
11-Jul-2026, 11:30 am
N/a
📍 BIJNOR, UTTAR PRADESH
N/a
📍 BIJNOR, UTTAR PRADESH
N/a
📍 BULANDSHAHR, UTTAR PRADESH
Ntpc Limited
📍 VARANASI, UTTAR PRADESH
N/a
📍 MUZAFFARNAGAR, UTTAR PRADESH
Sign up now to access all documents
Main Document
BOQ
BOQ
GEM_GENERAL_TERMS_AND_CONDITIONS