ICU Ventilators (V2)
Vadodara District Panchayat
Bid Publish Date
08-Jul-2026, 3:55 pm
Bid End Date
07-Aug-2026, 4:00 pm
EMD
₹1,20,000
Location
Progress
Quantity
5
Bid Type
Two Packet Bid
Public procurement opportunity for N/a ICU Ventilators (V2) (Q2) in MUMBAI, MAHARASHTRA. Quantity: 5 issued by. Submission Deadline: 07-08-2026 16: 00: 00. View full details and respond.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
ICU Ventilators (V2) (Q2)
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
GEM_GENERAL_TERMS_AND_CONDITIONS
Vadodara District Panchayat
Nmdc Limited
BELLARY, KARNATAKA
All India Institute Of Medical Sciences (aiims)
KAMRUP, ASSAM
N/a
CENTRAL DELHI, DELHI
N/a
RANCHI, JHARKHAND
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| GENERAL | Product Description | ICU Ventilator |
| PRODUCT INFORMATION | Patient Type | Adult & pediatric |
| PRODUCT INFORMATION | Type of technology | Turbine |
| PRODUCT INFORMATION | Tidal volume in ml | (20 ml or less) to (1500 ml or more) |
| PRODUCT INFORMATION | Respiration rate, breaths/min | up to 80 or more |
| PRODUCT INFORMATION | Trigger mechanism | Pressure /flow |
| PRODUCT INFORMATION | FiO2% | 21 to 100 |
| PRODUCT INFORMATION | Inspiratory flow rate, L/min | upto 200 or more |
| PRODUCT INFORMATION | Inspiratory pressure, cm H2O | upto 80 or more |
| PRODUCT INFORMATION | IE ratio | 1:10 to 4:1 |
| PRODUCT INFORMATION | Sigh breath function | Yes |
| PRODUCT INFORMATION | PEEP/CPAP, cm H2O | upto 40 or more |
| PRODUCT INFORMATION | Pressure support, cm H2O | 0 to 40 or more |
| PRODUCT INFORMATION | Leak compensation | Yes |
| PRODUCT INFORMATION | Auto 100%/Increase O2 button | Yes |
| PRODUCT INFORMATION | Control panel lock | Yes |
| PRODUCT INFORMATION | Facility for double lung ventilation | No, Yes |
| PATIENT ASSESSMENT TOOLS | Maximum wave forms displayed | 3 (Pressure and time, volume and time , flow and time) |
| PATIENT ASSESSMENT TOOLS | Number of loops | 2 loops (P-V, F-V) with facility of saving of 1 Loops for reference |
| PATIENT ASSESSMENT TOOLS | Maximum trending time in hrs | ≥72 hr |
| PATIENT ASSESSMENT TOOLS | Lung recruitment tools (PV loops) / OLT (Open lung tools) | No, Yes |
| PATIENT ASSESSMENT TOOLS | Lung mechanics visualization tool | No, Yes |
| PATIENT ASSESSMENT TOOLS | Capnography/CO2 monitoring | Yes |
| PATIENT ASSESSMENT TOOLS | Esophageal / transpulmonary pressure monitoring | Yes, No |
| PATIENT ASSESSMENT TOOLS | Modes of ventilation | Volume controlled, Pressure Controlled, Pressure Support, SIMV with Pressure support, SIMV with volume control with pressure support, CPAP/PEEP, Inverse Ratio Ventilation, Non invasisve ventilation, Apnea /back up ventilation, SIMV (VC) with Pressure support, SIMV (PC) with Pressure Support, SIMV (PRVC) with Pressure Support |
| PATIENT ASSESSMENT TOOLS | APRV(Airway Pressure Release Ventilation) /Bivent/Bi level | No, Yes |
| PATIENT ASSESSMENT TOOLS | MMV(Mandatory Minute Ventilation) + PSV (Pressure Support Ventilation) /ASV( Adaptive Support Ventilation ) or ALPV(Adaptive Lung Protection Ventilation) or Automode | Yes |
| PATIENT ASSESSMENT TOOLS | PRVC(Pressure-Regulated Volume Control ventilation)/Auto flow | Yes |
| PATIENT ASSESSMENT TOOLS | High flow oxygen therapy | No |
| PATIENT ASSESSMENT TOOLS | Automatic weaning system provided | No, Yes |
| PATIENT ASSESSMENT TOOLS | Volume Support | No |
| PATIENT ASSESSMENT TOOLS | Ventilation monitoring facility | The Ventillator is a Microprocessor Controlled ventilator with integrated facility for Ventilation monitoring |
| PATIENT ASSESSMENT TOOLS | Monitored / Displayed parameters | Peak inspiratory pressure, Mean airway pressure, PEEP pressure, Tidal volume, Minute volume, Spontaneous minute volume, FiO2 (analyzed %), Respiratory rate, Inspiratory time, Expiratory time, IE ratio, Plateau Pressure |
| PATIENT ASSESSMENT TOOLS | Availability of Status indicator on display | Ventilator mode, Battery life, patient data, alarm settings, clock |
| PATIENT ASSESSMENT TOOLS | Patient alarms | Low/high FiO2, Low/high minute volume, Low inspiratory pressure, High pressure, Low PEEP, High PEEP, Apnea, Continuous high pressure/occlusion, Inverse IE, High respiratory rate, Breathing circuit disconnect |
| PATIENT ASSESSMENT TOOLS | Equipment alarms | Gas-supply failure, Power failure, Vent inoperative, Low battery, Self-diagnostic |
| PATIENT ASSESSMENT TOOLS | RSBI (Rapid Shallow Breathing Index) | Yes |
| PATIENT ASSESSMENT TOOLS | Expiratory Time constant ( Tcexp) | No, Yes |
| PATIENT ASSESSMENT TOOLS | Compliance static and/or dynamic | Yes |
| PATIENT ASSESSMENT TOOLS | Inspired and/or expired resistance | Yes |
| PATIENT ASSESSMENT TOOLS | Occlusion pressure | No, Yes |
| PATIENT ASSESSMENT TOOLS | Inspiratory and expiratory hold | Yes |
| PATIENT ASSESSMENT TOOLS | Spontaneous frequency | Yes |
| PATIENT ASSESSMENT TOOLS | Total peep, intrinsic peep, extrinsic peep | Yes |
| PATIENT ASSESSMENT TOOLS | Expiratory block is autoclavable and no routine calibration required | Yes |
| PATIENT ASSESSMENT TOOLS | Auto compensation for ET Tube | Yes, No |
| PATIENT ASSESSMENT TOOLS | Facility for automatic compliance & Leakage compensation for circuit available | Yes |
| PATIENT ASSESSMENT TOOLS | RS 232 out put port | Yes |
| PATIENT ASSESSMENT TOOLS | USB/Memory card | Yes, No |
| PATIENT ASSESSMENT TOOLS | Availability of Remote alarm/display port | Yes |
| PATIENT ASSESSMENT TOOLS | Facility to Report (vent alarms and patient status) | Yes |
| PATIENT ASSESSMENT TOOLS | HL/7 Compliant out put | Yes |
| PATIENT ASSESSMENT TOOLS | Type of coloured display | LED/LCD/TFT |
| PATIENT ASSESSMENT TOOLS | Display should be touch screen | Yes |
| PATIENT ASSESSMENT TOOLS | NIV (Non Invasive Ventilation) to be possible in all modes of ventilation available | Yes |
| PATIENT ASSESSMENT TOOLS | Minimum Size of display (±2%) | 12.0 |
| PATIENT ASSESSMENT TOOLS | Graphic display have automatic scaling facility for waves | Yes |
| HARDWARE AND ELECTRICAL REQUIREMENTS | Power supply | 220-240 V , 50 Hz AC |
| HARDWARE AND ELECTRICAL REQUIREMENTS | Provision of UPS | Yes, No |
| HARDWARE AND ELECTRICAL REQUIREMENTS | Backup time in hrs | 1, 2, NA if not provided |
| HARDWARE AND ELECTRICAL REQUIREMENTS | Internal backup battery | Yes |
| HARDWARE AND ELECTRICAL REQUIREMENTS | Backup time of internal battery in mins | 30 mins or more |
| HARDWARE AND ELECTRICAL REQUIREMENTS | Built in air source | Turbine (In built) |
| HARDWARE AND ELECTRICAL REQUIREMENTS | Availability of stand alone compressor | Yes, No |
| HARDWARE AND ELECTRICAL REQUIREMENTS | Compressor shall provide an oil free Medical air, with Peak output flow should be minimum 150 LPM and Air quality complying with ISO compressed air purity class | Yes, NA (for turbine) |
| HARDWARE AND ELECTRICAL REQUIREMENTS | Seller shall ensure compatibility of compressor with ventilator | Yes, NA (for Turbine) |
| HARDWARE AND ELECTRICAL REQUIREMENTS | Nebulizer with particle size less than 3 micron | Yes |
| ADDITIONAL ACCESSORIES | Number of reusable silicon breathing circuits | 2 |
| ADDITIONAL ACCESSORIES | NV mask(Re usable)-Small,medium and large | 2 Each |
| ADDITIONAL ACCESSORIES | Flow sensor Placement | Distal |
| ADDITIONAL ACCESSORIES | Humidifier: Servo controlled with digital monitoring of inspired gas temperature with heating wire | 1, 2, NA |
| ADDITIONAL ACCESSORIES | Trolley for ventilator with circuit holding arm | Yes |
| CERTIFICATIONS | Compliance to Medical Device Rules (MDR) 2017 as amended till date | Yes |
| CERTIFICATIONS | Availability of valid Medical Device license for the product issued from the competent authority defined under Drugs and Cosmetic Act 1940 and Rules made there under as amended till date | Yes |
| CERTIFICATIONS | Availability of Test Report for each supplied batch/product as per Medical Device Rule (MDR) 2017 as amended till date | Yes |
| CERTIFICATIONS | Submission of all necessary certifications, licenses and test reports to the buyer at the time of bid submission or along with supplies as per buyer requirement | Yes |
| MISCELLANEOUS PARAMETERS | OEM/Reseller (if supplied by reseller shall ensure uninterrupted availability of all spares for 10 years) | Yes |
| MISCELLANEOUS PARAMETERS | Availability of toll free facility for technical support maintened by OEM or authorized agencies | Yes |
| MISCELLANEOUS PARAMETERS | During the warranty period it shall be ensured that all the break down calls are attended with in 24 hrs and the complete details of service agents / contact details should be furnished to buyer and consignee at time of supplies | Yes |
| MISCELLANEOUS PARAMETERS | User/Technical/Maintenance manuals to be supplied in English in hard and soft copy | Yes |
| MISCELLANEOUS PARAMETERS | Details of equipments and procedures required for local calibration and routine maintenance to be supplied and advanced maintenance task documentation also to be furnished | Yes |
| MISCELLANEOUS PARAMETERS | List of important spares and accessories, with their part numbers and price lists to be supplied to the buyer at the time of supplying the equipment | Yes |
| MISCELLANEOUS PARAMETERS | Demonstration of equipment and training to be provided after completing supplies before acceptance | Yes |
| MISCELLANEOUS PARAMETERS | The Principal Manufacturer must have direct Presence/approved service center In India | Yes |
| MISCELLANEOUS PARAMETERS | Copies of reports and certifications to be furnished to buyer on demand at time of supplies | Yes |
| WARRANTY | Warranty (years) | 5 Or higher |
Discover companies most likely to bid on this tender
Certificate (Requested in ATC)
OEM Authorization Certificate
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Directorate Of Purchase And Stores
📍 MUMBAI, MAHARASHTRA
All India Institute Of Medical Sciences (aiims)
📍 NADIA, WEST BENGAL
N/a
📍 GAUTAM BUDDHA NAGAR, UTTAR PRADESH
Gujarat Cancer & Research Institute
📍 AHMEDABAD, GUJARAT
All India Institute Of Medical Sciences (aiims)
📍 JODHPUR, RAJASTHAN
Sign up now to access all documents
Main Document
CATALOG Specification
GEM_GENERAL_TERMS_AND_CONDITIONS