Echo Cardiography Scanning Machine (V2)
N/a
Progress
Quantity
1
Bid Type
Two Packet Bid
A tender has been published for N/a Echo Cardiography Scanning Machine (V2) (Q2) in SURAT, GUJARAT. Quantity: 1 by. Submission Deadline: 14-07-2026 18: 00: 00. Check eligibility and apply.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
Echo Cardiography Scanning Machine (V2) (Q2)
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
N/a
N/a
PONDICHERRY, PUDUCHERRY
N/a
LUCKNOW, UTTAR PRADESH
Health Department,madhya Pradesh
BETUL, MADHYA PRADESH
N/a
CENTRAL DELHI, DELHI
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| Types of Probes & Features | Cardiac and Vascular Probes Configuration | TTE Phased Array, TEE Phased Array, Linear Probe |
| Types of Probes & Features | TTE(Transthoracic) Probe Type | Adult, Pediatric, Neonatal |
| Types of Probes & Features | TEE Adult Probe biplane and Multiplane frequency, in MHz | 2 to 7.5 MHz (±2), Not Applicable |
| Types of Probes & Features | TEE Pediatric Probe Required | Yes, No |
| Types of Probes & Features | TEE Pediatric Probe frequency, in MHz | 3 to 8 MHz (±2), Not Applicable |
| Types of Probes & Features | Linear Probe for linear/ vascular applications required | Yes, No |
| Types of Probes & Features | Adult/Pediatric Linear probe frequency in MHz | 5 to 14 MHz (±2), 5 to 10MHz (±2), Not Applicable |
| Types of Probes & Features | No of Adult TTE Probes Required | 1, NA |
| Types of Probes & Features | No of Pediatric TTE Probes Required | 1, NA |
| Types of Probes & Features | No of Neonatal TTE Probes Required | 1, NA |
| Types of Probes & Features | No of Adult TEE Probes Required | 1, NA |
| Types of Probes & Features | No of Pediatric TEE Probes Required | 1, NA |
| Types of Probes & Features | No of Pediatric 3D/4D TEE Probes Required | 1, NA |
| Types of Probes & Features | No of Neonatal TEE Probes Required | 1, NA |
| Types of Probes & Features | No of Adult/pediatric Linear Probes supplied | 1, NA |
| Types of Probes & Features | Dedicated 3D/4D volume imaging for cardiology TTE ad TEE | Yes, No |
| Types of Probes & Features | Live 3 D imaging in color doppler system | Yes, No |
| Types of Probes & Features | Colour Doppler system with all application packages ,Quad loop for serial studies with high frame rate revies, harmonic imaging capability in all modes and integrated stress echo package digital storage and retrieval | Yes, No |
| Types of Probes & Features | High-definition acoustic zoom provision for enlarging sections of 2D and Colour flow images with more acoustic information for greater clarity and detail while maintaining an optimal frame rate | Yes |
| Types of Probes & Features | Provision of Tissue Colorization (B-Colour) for improved contrast resolution | Yes |
| Types of Probes & Features | Application software | Adult, Pediatric, Neonatal, Vascular applications and Transesophagal applications |
| Types of Probes & Features | Cine Loop Features | Yes, No |
| Types of Probes & Features | Frame grabber facility for post analysis | Yes |
| Types of Probes & Features | Facility of Various maps for pre and post processing | Yes, No |
| Types of Probes & Features | ECG trigger facility | Yes, No |
| Types of Probes & Features | User defined Preset | Yes, No |
| Types of Probes & Features | Dedicated integrated dynamic stress echo package for flexible user defined protocols with stacked sub loops facility and contrast stress protocol usable for stress echocardiography | Yes, No |
| Types of Probes & Features | Number of transducer/probe ports | 1, 2, 3, 4 |
| Scan Modes and Performance Parameters | Cardiac 3-D freehand Option | No |
| Scan Modes and Performance Parameters | Cardiac 3D/4D automatic Option | No |
| Scan Modes and Performance Parameters | B-mode | Yes |
| Scan Modes and Performance Parameters | M Mode | Yes |
| Scan Modes and Performance Parameters | Contrast Harmonic/Agent Imaging with angio mode | Yes, No |
| Scan Modes and Performance Parameters | Tissue harmonic imaging mode | Yes |
| Scan Modes and Performance Parameters | Provision of Harmonic imaging in TTE, TEE and Linear Probes | Yes |
| Scan Modes and Performance Parameters | Color Doppler 3-D/4-D option | No |
| Scan Modes and Performance Parameters | Power Dopple 3-D/4-D option | No |
| Scan Modes and Performance Parameters | Tissue Doppler imaging | Yes |
| Scan Modes and Performance Parameters | Contrast-enhanced ultrasound (CEUS) option | No |
| Scan Modes and Performance Parameters | Tissue synchronization, tissue velocity | Yes |
| Scan Modes and Performance Parameters | Cardiac Shear wave elastography | Yes, No |
| Scan Modes and Performance Parameters | Cardiac compression elastography | Yes, No |
| Scan Modes and Performance Parameters | Provision for higher sensitivity for low frequency doppler in all probes | Yes |
| Scan Modes and Performance Parameters | Latest generation Electronic Phased/sector array Colour Doppler system | Yes |
| Scan Modes and Performance Parameters | Number of Channels in color doppler system | 5000000 or more (if channels are being designated as digital channels) |
| Scan Modes and Performance Parameters | System should be capable of generating real time live 3- D images | Yes, No, Yes with MV No Analysis |
| Scan Modes and Performance Parameters | Provision of Echocardiographic strain and strain-rate imaging with 2 D imaging | Yes |
| Image display and processing | DICOM 3 Compliant | Yes |
| Image display and processing | Automated B-mode (2-D) image | Yes |
| Image display and processing | Automated CDI image optimization | Yes |
| Image display and processing | Automated PW Doppler image optimization | Yes |
| Image display and processing | Grayscale levels | 256 |
| Image display and processing | Image magnification (zoom) | Yes |
| Image display and processing | Real-time image | Yes |
| Image display and processing | Frozen image | Yes |
| Image display and processing | Touch Screen | Yes, No |
| Image display and processing | Monitor display size, cm (in) | 21 Inch(±1) Or higher |
| Image display and processing | Split screen | Twin View |
| Image display and processing | Single/dual monitors | Single |
| Image display and processing | Depth, cm | ≥30 |
| Image display and processing | POST PROCESSING | Yes |
| Image display and processing | SELECTABLE DYNAMIC RANGE | Yes |
| Image display and processing | SPECTRUM ANALYZER | Yes |
| Image display and processing | DIGITAL IMAGE STORAGE | Yes |
| Image display and processing | CINE LOOP PLAYBACK | Yes |
| Image display and processing | Speckle-tracking strain and strain rate | Yes |
| Image display and processing | Analysis and calculation packages | 2-D wall motion tracking, 3-D wall motion tracking, Cardiac, Mitral valve analysis, User-programmable calculations, No |
| Image display and processing | Automated | Yes |
| Image display and processing | Digital calipers | Yes |
| Image display and processing | Customizable presets | Yes |
| Image display and processing | On-screen annotation | Yes |
| Image display and processing | USB connector | Yes |
| Image display and processing | Type of printer provided with the echo cardio machine | Themal Printer, B/W Laser Printer, Color Laser Printer |
| Image display and processing | Facility for high definition digital acquisition, review and editing of complete patient studies | Yes |
| Image display and processing | Type of processor in PC | i7 or Latest, NA |
| Image display and processing | Conectivity between Echo cardiogram and PC | Through IMS/Equivalent Software, NA |
| Image display and processing | PC with all software inclusive interfaced with echocardiograph machine | Yes, NA |
| Image display and processing | Inkjet printer provided with computer for reporting | Yes, No |
| Image display and processing | Glossy Colour Print Paper supplied | 500 sheets, 1000 sheets, Not provided |
| Image display and processing | ECG Cable | 2, NA |
| Image display and processing | Echo cardiography sytem to be DICOM Ready | Yes |
| Image display and processing | Dicom Interfacability to HIS | Yes |
| Image display and processing | Dicom Interfacability Dicom to PACS | Yes |
| Image display and processing | Interfacability Dicom to RIS | Yes, No |
| Power Requriments | Power input, VAC | 220-240VAC, 50Hz fitted with Indian plug |
| Power Requriments | Resettable over current breaker shall be fitted for protection | Yes |
| Power Requriments | Power bakup | UPS |
| Power Requriments | Back up time in minutes | 30, 60, 90, 120 Or higher |
| WARRANTY | Warranty in years (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) | 5.0 |
| MISCELLANEOUS PARAMETERS | OEM/Reseller shall ensure uninterrupted availability of all spares for 10 years | Yes |
Discover companies most likely to bid on this tender
Experience Criteria
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
Additional Doc 1 (Requested in ATC)
Additional Doc 2 (Requested in ATC)
Additional Doc 3 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
N/a
📍 CENTRAL DELHI, DELHI
All India Institute Of Medical Sciences (aiims)
📍 BHOPAL, MADHYA PRADESH
Central Health Service Ministry Of Health And Family Welfare
📍 NEW DELHI, DELHI
Central Health Service Ministry Of Health And Family Welfare
📍 NEW DELHI, DELHI
Sree Chitra Tirunal Institute For Medical Sciences And Technology (sctimst)
📍 THIRUVANANTHAPURAM, KERALA
Sign up now to access all documents
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS