Echo Cardiography Scanning Machine (V2)
Health Department,madhya Pradesh
BETUL, MADHYA PRADESH
Bid Publish Date
27-Jun-2026, 2:06 pm
Bid End Date
18-Jul-2026, 5:00 pm
EMD
₹1,60,000
Location
Progress
Quantity
1
Bid Type
Two Packet Bid
All India Institute Of Medical Sciences, Bhopal (Madhya Pradesh) invites bids for an Echo Cardiography Scanning Machine (V2) with comprehensive probe configurations and advanced imaging features. The procurement includes multiple probes (adult/pediatric TTE, TEE, neonatal, linear), 3D/4D capabilities, color Doppler, and tissue colorization, plus DICOM readiness and HIS/PACS interfacing. Estimated value is not disclosed; EMD is ₹160000. Delivery, installation, training, and statutory clearances are bundled in scope. This tender emphasizes OEM/authorized reseller involvement, Make in India authorisation, and extensive software packages. The buyer addition terms permit quantity variations up to 50% and require prior government/PSU supply experience. The award target is for a complete, ready-to-operate system with integration capabilities and post-installation support.
EMD of ₹160000 must be submitted; bids failing to provide EMD are non-responsive
3 years of prior government/PSU supply experience with documentary support is required
Delivery, installation, testing, commissioning, and operator training to be conducted by OEM-certified personnel
50% quantity variation right reserved by buyer; extended delivery time rules apply
Make in India authorization and GST adherence are mandatory; performance/warranty terms to be defined
Details to be specified by buyer; EMD must be accompanied; vendor to submit invoicing terms per contract
Delivery period and installation window to be determined in contract; option for extended delivery as per quantity variation
LD provisions to be included in contract for delays; performance milestones to be defined by AIIMS
3+ years supplying echo cardiography systems to government or PSU entities
Demonstrated financial stability and annual turnover compliant with tender requirements
OEM authorization and valid Make in India certificate
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
Echo Cardiography Scanning Machine (V2) (Q2)
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
ATC
OTHER
GEM_GENERAL_TERMS_AND_CONDITIONS
Health Department,madhya Pradesh
BETUL, MADHYA PRADESH
N/a
N/a
PONDICHERRY, PUDUCHERRY
N/a
LUCKNOW, UTTAR PRADESH
N/a
CENTRAL DELHI, DELHI
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| Types of Probes & Features | Cardiac and Vascular Probes Configuration | TTE Phased Array, TTE Matrix Array, TEE Phased Array, TEE Matrix Array, Linear Probe |
| Types of Probes & Features | TTE(Transthoracic) Probe Type | Adult, Pediatric, Neonatal |
| Types of Probes & Features | TEE Adult Probe biplane and Multiplane frequency, in MHz | 2 to 7.5 MHz (±2) |
| Types of Probes & Features | TEE Pediatric Probe Required | No |
| Types of Probes & Features | TEE Pediatric Probe frequency, in MHz | Not Applicable |
| Types of Probes & Features | Linear Probe for linear/ vascular applications required | Yes |
| Types of Probes & Features | Adult/Pediatric Linear probe frequency in MHz | 5 to 14 MHz (±2) |
| Types of Probes & Features | No of Adult TTE Probes Required | 1 |
| Types of Probes & Features | No of Pediatric TTE Probes Required | 1, NA |
| Types of Probes & Features | No of Neonatal TTE Probes Required | NA |
| Types of Probes & Features | No of Adult TEE Probes Required | 1 |
| Types of Probes & Features | No of Pediatric TEE Probes Required | NA |
| Types of Probes & Features | No of Pediatric 3D/4D TEE Probes Required | NA |
| Types of Probes & Features | No of Neonatal TEE Probes Required | NA |
| Types of Probes & Features | No of Adult/pediatric Linear Probes supplied | 1 |
| Types of Probes & Features | Dedicated 3D/4D volume imaging for cardiology TTE ad TEE | Yes |
| Types of Probes & Features | Live 3 D imaging in color doppler system | Yes |
| Types of Probes & Features | Colour Doppler system with all application packages ,Quad loop for serial studies with high frame rate revies, harmonic imaging capability in all modes and integrated stress echo package digital storage and retrieval | Yes |
| Types of Probes & Features | Provision of Tissue Colorization (B-Colour) for improved contrast resolution | Yes |
| Types of Probes & Features | Application software | Adult, Pediatric, Neonatal, Vascular applications and Transesophagal applications |
| Types of Probes & Features | Cine Loop Features | Yes |
| Types of Probes & Features | Frame grabber facility for post analysis | Yes |
| Types of Probes & Features | Facility of Various maps for pre and post processing | Yes |
| Types of Probes & Features | ECG trigger facility | Yes |
| Types of Probes & Features | User defined Preset | Yes |
| Types of Probes & Features | Dedicated integrated dynamic stress echo package for flexible user defined protocols with stacked sub loops facility and contrast stress protocol usable for stress echocardiography | Yes |
| Types of Probes & Features | Number of transducer/probe ports | 4 |
| Scan Modes and Performance Parameters | Cardiac 3-D freehand Option | Yes |
| Scan Modes and Performance Parameters | Cardiac 3D/4D automatic Option | Yes |
| Scan Modes and Performance Parameters | Contrast Harmonic/Agent Imaging with angio mode | Yes |
| Scan Modes and Performance Parameters | Color Doppler 3-D/4-D option | No |
| Scan Modes and Performance Parameters | Power Dopple 3-D/4-D option | Yes |
| Scan Modes and Performance Parameters | Contrast-enhanced ultrasound (CEUS) option | Yes |
| Scan Modes and Performance Parameters | Tissue synchronization, tissue velocity | Yes |
| Scan Modes and Performance Parameters | Cardiac Shear wave elastography | No |
| Scan Modes and Performance Parameters | Cardiac compression elastography | No |
| Scan Modes and Performance Parameters | Provision for higher sensitivity for low frequency doppler in all probes | Yes |
| Scan Modes and Performance Parameters | Latest generation Electronic Phased/sector array Colour Doppler system | Yes |
| Scan Modes and Performance Parameters | Number of Channels in color doppler system | 50000 or more (if channels are being designated as digital channels) |
| Scan Modes and Performance Parameters | System should be capable of generating real time live 3- D images | Yes |
| Image display and processing | DICOM 3 Compliant | Yes |
| Image display and processing | Automated B-mode (2-D) image | Yes |
| Image display and processing | Automated CDI image optimization | Yes |
| Image display and processing | Automated PW Doppler image optimization | Yes |
| Image display and processing | Touch Screen | Yes |
| Image display and processing | Monitor display size, cm (in) | 21 Inch(±1) Or higher |
| Image display and processing | Split screen | Twin View |
| Image display and processing | Single/dual monitors | Dual (image display on touch panel) |
| Image display and processing | Speckle-tracking strain and strain rate | Yes |
| Image display and processing | Analysis and calculation packages | 2-D wall motion tracking, 3-D wall motion tracking, Cardiac, Mitral valve analysis, User-programmable calculations, No |
| Image display and processing | Type of printer provided with the echo cardio machine | Themal Printer |
| Image display and processing | Type of processor in PC | i7 or Latest |
| Image display and processing | Conectivity between Echo cardiogram and PC | Through IMS/Equivalent Software |
| Image display and processing | PC with all software inclusive interfaced with echocardiograph machine | Yes |
| Image display and processing | Inkjet printer provided with computer for reporting | No |
| Image display and processing | Glossy Colour Print Paper supplied | Not provided |
| Image display and processing | ECG Cable | 2 |
| Image display and processing | Echo cardiography sytem to be DICOM Ready | Yes |
| Image display and processing | Dicom Interfacability to HIS | Yes |
| Image display and processing | Dicom Interfacability Dicom to PACS | Yes |
| Image display and processing | Interfacability Dicom to RIS | Yes |
Discover companies most likely to bid on this tender
GST registration certificate
Permanent Account Number (PAN) card
Experience certificates for supply of echo systems to Govt/PSU/large private entities
Financial statements for last 3 years or audited turnover
EMD submission proof
Technical bid documents and bill of materials
OEM authorization and Make in India certificate
Supply/PO copies demonstrating prior procurement experience
Key insights about MADHYA PRADESH tender market
Bidders should assemble all required documents, including GST, PAN, experience certificates, financials, and OEM authorizations. Ensure EMD of ₹160000 is ready as DD or online payment. Provide Make in India certificate and evidence of government/PSU supply experience. Include complete BOQ or equivalent specification list.
Submit GST certificate, PAN card, last 3 years financial statements, experience orders for similar systems, OEM authorization, Make in India certificate, EMD proof, and technical bid with BOM. Include installation, commissioning, training plan, and warranty terms as per buyer terms.
System must support live 3D imaging, 4D volume imaging, color Doppler with harmonic imaging, tissue colorization, and speckle-tracking. Probes should include adult/pediatric TTE, neonatal, TEE (biplane/multiplane), and linear vascular probes with defined MHz ranges.
Contract will specify delivery and commissioning timelines; option for extended delivery up to 50% quantity is permitted, with minimum 30 days added only when original delivery period is short. OEM-certified installation is required and training provided to operators.
EMD is ₹160000. Eligibility requires minimum 3 years of government/PSU supply experience, Make in India authorization, and demonstrated turnovers. Bidders must not be in liquidation and should provide undertaking; GST will be reimbursed per actual rates.
System must be DICOM Ready with DICOM 3 compliance, interfacing to HIS/PACS/RIS, and ensure PC connectivity with reporting printer; software must support automated B-mode/CDI optimization and PW Doppler imaging.
Contract will specify warranty duration and AMC options; installation and training by OEM resources; post-installation support coverage and response times should be defined in the purchase order.
N/a
📍 CENTRAL DELHI, DELHI
Central Health Service Ministry Of Health And Family Welfare
📍 NEW DELHI, DELHI
Central Health Service Ministry Of Health And Family Welfare
📍 NEW DELHI, DELHI
N/a
📍 SURAT, GUJARAT
Sree Chitra Tirunal Institute For Medical Sciences And Technology (sctimst)
📍 THIRUVANANTHAPURAM, KERALA
Sign up now to access all documents
Main Document
CATALOG Specification
ATC
OTHER
GEM_GENERAL_TERMS_AND_CONDITIONS