Neonatal Ventilators
Aligarh Muslim University (amu)
ALIGARH, UTTAR PRADESH
Bid Publish Date
08-Jul-2026, 4:39 pm
Bid End Date
29-Jul-2026, 4:00 pm
EMD
₹2,80,000
Progress
Quantity
2
Bid Type
Two Packet Bid
A tender has been published for N/a Neonatal Ventilators (Q2). Quantity: 2 by. Submission Deadline: 29-07-2026 16: 00: 00. Check eligibility and apply.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
Neonatal Ventilators (Q2)
Advisory Bank
State Bank of India
ePBG Percentage
5%
ePBG Duration (Months)
12
Max Delivery Days
15
Delivery Locations
1
Delivery Cities
Dadra And Nagar Haveli
Delivery Pincodes
396230
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| Heena | 396230,CENTRAL MEDICAL STORE, OPP SHRI VINOBA BHAVE CIVIL HOSPITAL, WORKING WOMEN HOSTEL CAMPUS, SAYLI ROAD, SILVASSA | Dadra And Nagar Haveli | The Dadra And Nagar Haveli And Daman And Diu | 396230 | 2 | 15 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Aligarh Muslim University (amu)
ALIGARH, UTTAR PRADESH
Gujarat Medical Education And Research Society (gmers)
AHMEDABAD, GUJARAT
Gujarat Medical Education And Research Society (gmers)
GANDHI NAGAR, GUJARAT
Directorate Of Medical Education And Training
AGRA, UTTAR PRADESH
Directorate Of Medical Education And Training
AGRA, UTTAR PRADESH
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| GENERAL | Product Description | Neonatal Ventilator |
| PERFORMANCE PARAMETERS | Patient Type | Neonatal |
| PERFORMANCE PARAMETERS | Tidal Volume Range In ml | 2 to 300 |
| PERFORMANCE PARAMETERS | Respiratory Rate in Range,Breath/min | 1 to 120 |
| PERFORMANCE PARAMETERS | Trigger Sensitivity Mechanism | Flow |
| PERFORMANCE PARAMETERS | FiO2 Range in % | 21 to 100 |
| PERFORMANCE PARAMETERS | Inspiratory Flow Rate range L/min | 0.4 to 100 |
| PERFORMANCE PARAMETERS | Flow Pattern/Waveform Adjustment | Yes |
| PERFORMANCE PARAMETERS | Inspiratory Pressure range in cmH20 | 0 to 50 |
| PERFORMANCE PARAMETERS | Sigh Breath Function | Yes |
| PERFORMANCE PARAMETERS | Inspiratory Time in sec | 0.15 to 5 |
| PERFORMANCE PARAMETERS | Flow Cycle in Percentage | 0 to 45 |
| PERFORMANCE PARAMETERS | Pressure Control in cmH20 | 0 to 50 |
| PERFORMANCE PARAMETERS | Inspiration Pause time in sec | 0.1 to 6 |
| PERFORMANCE PARAMETERS | Pressure Trigger cmH20 | 0.1 to 20 |
| PERFORMANCE PARAMETERS | Apnea time in sec | 10 to 60 |
| PERFORMANCE PARAMETERS | Expiratory Time in millisec | ≥ 200 |
| PERFORMANCE PARAMETERS | PEEP/CPAP Range in cmH20 | 0 to 45 |
| PERFORMANCE PARAMETERS | Flow Trigger in LPM | 0.1 to 15 |
| PERFORMANCE PARAMETERS | Bias Flow in LPM | Yes |
| PERFORMANCE PARAMETERS | Volume Limit in Ltrs | 0.02 to 2.5 |
| PERFORMANCE PARAMETERS | Leak Compensation Available | Yes |
| PERFORMANCE PARAMETERS | Auto 100% increase O2 Button | Yes |
| PERFORMANCE PARAMETERS | Inspiratory Pause Available | Yes |
| PERFORMANCE PARAMETERS | Expiratory Hold Available | Yes |
| PERFORMANCE PARAMETERS | Suction Control Option Available | Yes |
| PERFORMANCE PARAMETERS | Nasal CPAP Option Available | Yes |
| PERFORMANCE PARAMETERS | Auto PEEP Manoeuvre | No |
| PERFORMANCE PARAMETERS | Control Panel Lock | No |
| PERFORMANCE PARAMETERS | Facility for double lung ventilation | No |
| PERFORMANCE PARAMETERS | Integrated Air Compressor | Yes |
| VENTILATION MODES | PSV(Pressure supported ventilation) | Yes |
| VENTILATION MODES | Pressure Controlled 3 Selectable inspiratory pressure | Rectangle |
| VENTILATION MODES | P-CMV(Inspiration pressure control) | Yes |
| VENTILATION MODES | PC-AC With Expiratory Minimal volume | Yes |
| VENTILATION MODES | SIMV(Synchronized intermittent Mandatory Ventilation) with PCMV | Yes |
| VENTILATION MODES | ITT - Inspiratory Time Termination | Yes |
| VENTILATION MODES | CPAP:Continuos Positive Airway pressure Ventilation CPAP With backup Ventilation | Yes |
| VENTILATION MODES | High Frequency Oscillation Ventilator(HFOV) | Yes |
| VENTILATION MODES | NIV(Non Invasive Ventilation) Mode | Yes |
| HIGH FREQUENCY OSCILLATIONS | Mean Airway Pressure (MAP) | 5 to 50 |
| HIGH FREQUENCY OSCILLATIONS | Frequency (Hz) | 5 to 20 |
| HIGH FREQUENCY OSCILLATIONS | Amplitude | 0 to 100 |
| PATIENT ASSESSMENT TOOLS | Maximum Waveform Displayed | 3 |
| PATIENT ASSESSMENT TOOLS | Maximum Trending Time in Hours | ≥72 |
| PATIENT ASSESSMENT TOOLS | Number of Loops | 2 loops(p-v,f-v) |
| PATIENT ASSESSMENT TOOLS | Capnography/Co2 Monitoring | No |
| PATIENT ASSESSMENT TOOLS | Volume Guarantee | Yes |
| PATIENT ASSESSMENT TOOLS | APRV | No |
| PATIENT ASSESSMENT TOOLS | Oxygen Therapy | Yes |
| ADDITIONAL CAPABILITIES | Nebulizer with particle size less than 3 micron | Yes |
| ADDITIONAL CAPABILITIES | ETCO2 Inbuilt available | No |
| ADDITIONAL CAPABILITIES | Humidifier | Yes |
| MONITORED OR DISPLAYED | Peak Inspiratory Pressure Monitored | Yes |
| MONITORED OR DISPLAYED | Mean Airway Pressure | Yes |
| MONITORED OR DISPLAYED | PEEP Pressure | Yes |
| MONITORED OR DISPLAYED | Tidal Volume | Yes |
| MONITORED OR DISPLAYED | Minute Volume | Yes |
| MONITORED OR DISPLAYED | Spontaneous Minute Volume | Yes |
| MONITORED OR DISPLAYED | FiO2 Monitored | Yes |
| MONITORED OR DISPLAYED | Display Respiratory rate | Yes |
| MONITORED OR DISPLAYED | Display Inspiratory Time | Yes |
| MONITORED OR DISPLAYED | Display I:E Ratio | Yes |
| ALARMS | Low/High Fio2 | Yes |
| ALARMS | Low Minute Volume | Yes |
| ALARMS | High Minute Volume | Yes |
| ALARMS | Low Inspiratory Pressure | Yes |
| ALARMS | High Pressure | Yes |
| ALARMS | Loss of PEEP | Yes |
| ALARMS | Apnea | Yes |
| ALARMS | Continuous High pressure/Occlusion | Yes |
| ALARMS | Inverse I:E Ratio | Yes |
| ALARMS | High PEEP | Yes |
| ALARMS | Breathing Circuit Disconnect | Yes |
| ALARMS | Gas Supply Failure | Yes |
| ALARMS | Power Failure | Yes |
| ALARMS | Low Battery | Yes |
| HUMIDIFIER | Reusable Heated wire Provided for inspiratory Limb of breathing circuit & Water trap in expiratory limb available | 2 |
| HUMIDIFIER | Neonatal Humidifier Jar | 2 |
| HUMIDIFIER | Disposable Neonatal breathing circuit (dual heated wire) | 20 |
| HUMIDIFIER | Auto Feed Humidification chamber Available | Yes |
| HUMIDIFIER | Disposable Neonatal breathing circuit with single heated wire provided for inspiratory Limb with Water trap in expiratory limb available | NA |
| ADDITIONAL PARAMETERS | Output Ports Type | USB |
| ADDITIONAL PARAMETERS | Remote Alarm Display Port | No |
| ADDITIONAL PARAMETERS | Reporting (Vent alarms and Patient Status) | No |
| ADDITIONAL PARAMETERS | View Reports on Display | No |
| ADDITIONAL PARAMETERS | Save Data to USB | No |
| ADDITIONAL PARAMETERS | Send Data Via Network | No |
| ADDITIONAL PARAMETERS | Display Type | LCD/LED/TFT |
| ADDITIONAL PARAMETERS | Display Size in Inches | ≥ 15 Or higher |
| ADDITIONAL PARAMETERS | Can be used For Patient Transport | No |
| ACCESSORIES | Nasal CPAP Kit | 10 |
| ACCESSORIES | Number of Disposable flow sensor | 20 |
| ACCESSORIES | Number of Reusable flow sensor | 3 |
| ACCESSORIES | Trolley with ventillator with supporting arm from same manufacturer | Yes |
| ACCESSORIES | Autoclavable exhalation valve/expiratory cassette | 2 |
| ACCESSORIES | Test Lung Available | Yes |
| POWER REQUIREMENTS | Type of power supply in VAC,Hz | 220-240, 50Hz Single phase |
| POWER REQUIREMENTS | Mains cable to be atleast 3m length | Yes |
| POWER REQUIREMENTS | Operating time of battery in min | 30 |
| CERTIFICATIONS | Compliance to Medical Device Rules (MDR) 2017 as amended till date | Yes |
| CERTIFICATIONS | Availability of valid Medical Device license for the product issued from the competent authority defined under Drugs and Cosmetic Act 1940 and Rules made there under as amended till date | Yes |
| CERTIFICATIONS | Availability of Test Report for each supplied batch/product as per Medical Device Rule (MDR) 2017 as amended till date | Yes |
| WARRANTY | Warranty in Years (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) | 5.0 |
Discover companies most likely to bid on this tender
Certificate (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Gujarat Medical Services Corporation Limited (gmscl)
Chacha Nehru Bal Chikitsalaya
📍 EAST DELHI, DELHI
Health Services
📍 AIZAWL, MIZORAM
Kerala Medical Services Corporation Ltd
📍 THIRUVANANTHAPURAM, KERALA
N/a
📍 GAUTAM BUDDHA NAGAR, UTTAR PRADESH
Sign up now to access all documents
Main Document
CATALOG Specification
ATC