Rural Development Department Bihar Drinking Water ATM Tender 2025 - ISI/AAA/TRTL Standards Version 2 Water Vending Machine
Rural Development Department
SAMASTIPUR, BIHAR
Menu
Progress
Quantity
1
Bid Type
Two Packet Bid
Organization: Madhepura District Panchayats (Department of Panchayati Raj) seeks a ** Drinking Water ATM / Water Vending Machine (Version 2)**. Scope includes multiple payment modes (coin, RFID/NFC card, mobile wallet), water purification via RO with UV disinfection, chiller for cold water ~15°C, and integrated dosing pumps. The enclosure design requires robust MS framing, anti-skid flooring, and space for 20 L container filling. Estimated value and EMD data are not disclosed; however, the tender emphasizes on-site installation, commissioning, and post-installation training. The project targets reliable, safe drinking water vending with real-time purity parameter displays. Unique clause favors Madhepura district bidders for service delivery ease. This tender is structured to procure a turnkey Water ATM solution with end-to-end integration and after-sales support.
Water ATM with RO purification, UV disinfection and dosing pumps
Payment modes: coin acceptor, RFID/NFC card, mobile wallet
Chiller capable to deliver water at ~15°C
In-built CIP tank; anti-scalant dosing pump; pH correction dosing
Display: touch screen, backlit, shows pH, TDS, temperature
Option clause allows quantity change up to 25% with adjusted delivery
Bidders must supply NABL/ILAC-compliant test reports on demand
Emergency extension timelines tied to original delivery period with minimum 30 days
Payment to be made under milestone-based terms after commissioning; exact percentages to be defined in purchase order.
Delivery period may be adjusted based on option clause; minimum extension policy referenced in bid terms.
Penalties or LD to be defined in final contract; extension allowed with conditions.
Madhepura district registered bidders preferred
Prior experience with Water ATM installations or purification systems
Financial capability to undertake turnkey installation and warranty services
Rural Development Department
SAMASTIPUR, BIHAR
Rural Development Department
SAMASTIPUR, BIHAR
Sitamarhi District Panchayats
SITAMARHI, BIHAR
Rural Development Department
EAST CHAMPARAN, BIHAR
Rural Development Department
EAST CHAMPARAN, BIHAR
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| Coin / Card Acceptor / Quantity of Dispensing Water | Number of Dispensing points | 1, 2, 3, 4, 5, 6 Or higher |
| Coin / Card Acceptor / Quantity of Dispensing Water | Water Dispensing using coin acceptor | Yes, No |
| Coin / Card Acceptor / Quantity of Dispensing Water | Coins accepted for payment | Re.1, Rs. 2, Rs. 5, Rs.10, Rs. 20, NA |
| Coin / Card Acceptor / Quantity of Dispensing Water | Water Dispensing using RFID/NFC card | Yes, No |
| Coin / Card Acceptor / Quantity of Dispensing Water | Mobile Wallet accepted for payment | Yes, No |
| CAPACITY / TYPE / WATER SOURCE / OUTLET WATER QUALITY | Purification Capacity of Water ATM (LPH) | 20, 50, 100, 150, 200, 250, 300, 500, 1000, 2000 Or higher |
| CAPACITY / TYPE / WATER SOURCE / OUTLET WATER QUALITY | Type of Operation | Manual, Semi-Automatic, Automatic with Multi-Processor Integrated Control System and remotely conrolled web based Server system Or higher |
| CAPACITY / TYPE / WATER SOURCE / OUTLET WATER QUALITY | Water Source | Municipal Tap water, Surface Water, Borewell Water |
| TECHNOLOGY | Technology | Reverse Osmosis (RO), Ultra Filtration (UF), UF+RO, Nano Filtration (NF), CDI |
| TECHNOLOGY | Anti scalant dosing pump | Yes, No |
| TECHNOLOGY | pH Correction Dosing Pump | Yes, No |
| CONSTRUCTIONAL | Raw water Storage capacity (Indicate '0' for direct connection to continuous Tap Water source) | 0, 100, 200, 500, 1000, 2000, 3000, 5000, 8000, 10000 Or higher |
| CONSTRUCTIONAL | Raw water Storage Tank Material of Construction | Concrete, Mild Steel, Stainless Steel, FRP, HDPE, Poly Propylene (PP) |
| CONSTRUCTIONAL | Location of the Raw Water Storage Tank | Inside the ATM Enclosure, Under Ground, NA for Tap Water, Outside the ATM Enclosure |
| CONSTRUCTIONAL | Treated water Storage capacity | 10-20, 21-50, 51-100, 101-150, 151-200, 201-250, 251-300, 301-350, 351-400, 401-500, 501-600, 601-700, 701-800, 801-1000 Or higher |
| CONSTRUCTIONAL | Treated water Storage Tank Material of Construction | Stainless Steel 316 Gr, Stainless Steel 304 Gr, HDPE, PP Or higher |
| CONSTRUCTIONAL | Equipped with an in-built chiller unit for providing continuous cold water of temperature around 15 degree Celcius | Yes, No |
| CONSTRUCTIONAL | In-built Chiller Tank Capacity (Liter) | 10-20, 21-50, 51-100, 101-150, 151-200, 201-250, 251-300, 301-350, 351-400, 401-500, 501-600, 601-700, 701-800, 801-1000, NA Or higher |
| CONSTRUCTIONAL | Chiller Tank Material of Construction | Stainless Steel 316 Gr, Stainless Steel 304 Gr, NA Or higher |
| CONSTRUCTIONAL | Number of Filtration steps | 5, 7, 9 |
| CONSTRUCTIONAL | Provided with suitable vending place for filling container of 20 liters capacity | Yes, No |
| DISPLAY | Display of water purity parameters | Yes, No |
| DISPLAY | Display Type | LED, LCD, TFT, NA Or higher |
| DISPLAY | Backlit Display | Yes, No |
| DISPLAY | Touch Screen Display | Yes, No |
| DISPLAY | Display Size (Characters x Lines) | 4 x 2 (4 Ch x 2 lines), 8 x 2 (8 Ch x 2 lines), 16 x 2 (16 Ch x 2 lines), 20 x 2 (20 Ch x 2 lines), 7" Tablet, NA |
| DISPLAY | Display of oulet water TDS level | Yes, No |
| DISPLAY | Display of outlet water pH level | Yes, No |
| DISPLAY | Display of outlet water Temperature | Yes, No |
| Inlet / Feed Pump to feed water from raw water storage tank to filter | Inlet / Feed Pump Type | Horizontal Centrifugal, Vertical Centrifugal, NA for Tap water |
| Inlet / Feed Pump to feed water from raw water storage tank to filter | Number of Inlet / Feed Pumps | 1, 2, NA |
| Multi Media Filter Vessels for First stage filtration for suspended particles | Material Of Construction for Multi Media Filter Vessels | FRP, Steel, PP Or higher |
| Multi Media Filter Vessels for First stage filtration for suspended particles | Number of Multi Media Filter Vessels | 2, 1 Or higher |
| Multi-Port Valve to control filtration and backwash for media filter having sand & carbon | Type of Multi-Port Valve | Manual, Automatic, NA |
| Multi-Port Valve to control filtration and backwash for media filter having sand & carbon | Multi-Port Valve Material of Construction | ABS, PP, NA |
| Multi-Port Valve to control filtration and backwash for media filter having sand & carbon | Number of Multi-Port Valves | 1, 2, NA |
| Anti scalent Dosing Pump to inhibit scaling of hardness salt and silica on RO Membranes, doze pH and Cl as per water quality | Type of Anti scalent Dosing Pump | Electronic diaphragm, NA |
| Anti scalent Dosing Pump to inhibit scaling of hardness salt and silica on RO Membranes, doze pH and Cl as per water quality | Material Of Construction for Anti scalent Dosing Pump | PP, ABS, NA |
| Anti scalent Dosing Pump to inhibit scaling of hardness salt and silica on RO Membranes, doze pH and Cl as per water quality | Number of Anti scalent Dosing Pumps | 1, 2, NA |
| pH Correction Dosing Pump & Dosing Tank to dilute water with dosing chemicals | Type of pH Correction Pump | Electronic diaphragm, NA |
| pH Correction Dosing Pump & Dosing Tank to dilute water with dosing chemicals | Material Of Construction for pH Correction Dosing Pump | PP, ABS, NA |
| pH Correction Dosing Pump & Dosing Tank to dilute water with dosing chemicals | Number of pH Correction Dosing Pumps | 1, 2, 3, NA |
| pH Correction Dosing Pump & Dosing Tank to dilute water with dosing chemicals | Dosing Tank Material of Construction | LLDPE, HDPE, NA |
| High Pressure Pump to develop required pressure for Reverse Osmosis on RO Membranes | Type of High Pressure Pump | Vertical Centrifugal Pump, NA |
| High Pressure Pump to develop required pressure for Reverse Osmosis on RO Membranes | Material Of Construction for High Pressure Pump | PP, SS, NA |
| High Pressure Pump to develop required pressure for Reverse Osmosis on RO Membranes | Number of High Pressure Pumps | 1, 2, 3, NA Or higher |
| High Pressure Pump to develop required pressure for Reverse Osmosis on RO Membranes | Low pressure switch for Protection of HP pump from burn-out | Yes, NA |
| RO Pressure Vessel | Type of RO Pressure Vessel | Membrane housing mounted on skid - End port type, NA |
| RO Pressure Vessel | Material Of Construction for RO Pressure Vessel | FRP, SS, NA |
| RO Pressure Vessel | Number of RO Pressure Vessels | 1, 2, 3, 4, NA Or higher |
| Ultra Violet (UV) System to disinfect water, kill bacteria and micro-organisms | Material Of Construction for UV System | SS, ABS, NA |
| Ultra Violet (UV) System to disinfect water, kill bacteria and micro-organisms | Number of UV Systems | 1, 2, NA Or higher |
| Ultra Violet (UV) System to disinfect water, kill bacteria and micro-organisms | Number of UV Lights | 1, 2, 3, 4, 5, 6, NA Or higher |
| Ultra Violet (UV) System to disinfect water, kill bacteria and micro-organisms | Total UV Power | 12 Watts, 16 Watts, 48 Watts, NA |
| CIP (Clean-In-Place)Tank to mix / Dilute chemicals for membrane cleaning and permeate back wash | CIP Tank | Yes, No |
| CIP (Clean-In-Place)Tank to mix / Dilute chemicals for membrane cleaning and permeate back wash | CIP Tank Material of Construction | HDPE, FRP, LLDPE, NA |
| CIP (Clean-In-Place)Tank to mix / Dilute chemicals for membrane cleaning and permeate back wash | Number of CIP Tanks | 1, 2, NA Or higher |
| Power Source | Power Source | AC Power Supply, AC & DC (for dispensing only) Power Supply |
| Power Source | Power Supply | 230 ±10 V AC, 415 ±10 V AC |
| Power Source | Battery back-up time (Hours) | 6, 8, 10, 12, 14, 16, 18, 20, 22, 24 Or higher |
| Water ATM - Enclosure | Structure | Rigid structure made of MS frame, Rigid structure made of SS frame(3),, Rigid structure made of G.I. frame Or higher |
| Water ATM - Enclosure | Thickness of the frame of structure (mm) | 2.5, 2 Or higher |
| Water ATM - Enclosure | Material of Construction of Side Panels of Water ATM | Stainless Steel Sheet, Galvanized Steel Sheet Or higher |
| Water ATM - Enclosure | Side Panel Sheet Thickness (mm) | 0.6, 0.8, 1, 1.2 Or higher |
| Water ATM - Enclosure | PUF insulation of Side Panels of Water ATM | With, Without Or higher |
| Water ATM - Enclosure | PUF insulation of the door of Water ATM | With, Without Or higher |
| Water ATM - Enclosure | Provision for in-built litter space | Yes, No |
| Water ATM - Enclosure | Covered area of treatment plant enclosure (Square Foot) | 2-5, 5.1-10, 10.1-15, 15.1-20, 20.1-30, 30.1-40, 40.1-50, 50.1-60, 60.1-70, 70.1-80, 80.1-90, 90.1-100, 100.1-110, 110.1-120 Or higher |
| Water ATM - Enclosure | Shape of the Water ATM housing | Cubical, Cuboidal, Hexagonal, Cylindrical |
| Water ATM - Enclosure | Top Canopy of the Water ATM housing | Flat, Sloped, Dome |
| Water ATM - Enclosure | Headroom for the Water ATM enclosure (Foot) | 7.1-8.0, 8.1-9.0, 9.1-10.0 Or higher |
| Water ATM - Enclosure | Floor area around the Water ATM enclosure covered with anti-skid tiles | Yes, No |
| Water ATM - Enclosure | Water ATM enclosure protected with enclosed MS grill / mesh | Yes, No |
| Installation & Commissioning / Warranty | Trial Run and Training provided (inclusive in the Scope of Supply) (Days) | 5, 10 Or higher |
| Installation & Commissioning / Warranty | Warranty for storage Tanks (Year) | 1, 2, 3, 4, 5 Or higher |
| Installation & Commissioning / Warranty | Warranty for electrical motors (Year) | 1, 2, 3 Or higher |
| Installation & Commissioning / Warranty | Warranty for the filters (Year) | 1, 2, 3 Or higher |
| Installation & Commissioning / Warranty | Warranty for the system (Year) | 1, 2, 3 Or higher |
| Test Reports | Availability of Test Report from Central Govt /NABL/ILAC accredited lab to prove confirmity to specification | Yes, No |
| Test Reports | All the test reports and certificates shall furnish by the supplier to the buyer/consignee on demand | Yes, No |
Discover companies most likely to bid on this tender
GST registration certificate
Permanent Account Number (PAN) card
Experience certificates for similar Water ATM / purification projects
Financial statements (last 3 years)
EMD/Security deposit documentation
Technical bid documents and compliance certificates
OEM authorization/agency agreements (if applicable)
Product specifications and test reports (NABL/ILAC compliant)
Bidders should register as Madhepura district suppliers, obtain OEM authorizations, and prepare documents: GST, PAN, experience certificates, financial statements, EMD, and NABL/ILAC test reports. Ensure RO, UV, dosing pumps, and 15°C chiller compliance; submit technical specs and installation plan with warranty details.
Required documents include GST certificate, PAN, company financial statements for last 3 years, experience certificates for similar projects, EMD evidence, OEM authorization, technical compliance certificates, and NABL/ILAC test reports on demand by the buyer.
The system must include RO purification, UV disinfection, anti-scalant dosing, and pH correction dosing; display water quality parameters (pH, TDS, temperature); NABL/ILAC lab test reports should be available on demand; firmware-mounted touch screen display is required.
Delivery timelines follow the option clause allowing 25% quantity changes; delivery begins after order, with minimum 30 days extension if quantity increases; final delivery period will be specified in the purchase order and contract.
Payment terms are milestone-based after successful installation and commissioning; exact percentages and schedule are defined in the contract, with performance verification through trial run and training included.
Demonstrate district registration preference, relevant water purification/ATM experience, financial stability, and compliance with local procurement norms; provide OEM authorizations and prior project completion certificates to prove capability.
Suppliers must furnish NABL/ILAC-certified test reports proving conformance to water quality and safety standards; these reports must be readily available on demand and accompany the submission or be accessible via procurement portal.
Enclosure must feature MS frame, anti-skid floor, PU insulation for panels, covered treatment area, in-built litter space, and secure MS grill/mash; top canopy and footprint must align with site dimensions and provide safe operator access.
Panchayati Raj Department
📍 ARARIA, BIHAR
Begusarai District Panchayats
📍 BEGUSARAI, BIHAR
Rural Development Department
📍 ARARIA, BIHAR
Rural Development Department
📍 SAMASTIPUR, BIHAR
Panchayati Raj Department
📍 MUNGER, BIHAR
Sign up now to access all documents
Main Document
CATALOG Specification
GEM_GENERAL_TERMS_AND_CONDITIONS
Choose from flexible plans to access tender documents instantly
Main Document
CATALOG Specification
GEM_GENERAL_TERMS_AND_CONDITIONS