Kolhapur District Panchayats White LED Solar Street Lighting System Tender 2025 Maharashtra ISI/IS 550 2025
Kolhapur District Panchayats
KOLHAPUR, MAHARASHTRA
Bid Publish Date
12-Jan-2026, 6:05 pm
Bid End Date
27-Jan-2026, 4:00 pm
EMD
₹49,900
Location
Progress
Quantity
2
Bid Type
Two Packet Bid
Public procurement opportunity for N/a High Mast Lighting Tower for large area with LED Flood Lighting System (Q3) in AURAIYA, UTTAR PRADESH. Quantity: 2 issued by. Submission Deadline: 27-01-2026 16: 00: 00. View full details and respond.
Kolhapur District Panchayats
KOLHAPUR, MAHARASHTRA
Indian Army
RI BHOI, MEGHALAYA
Satara District Panchayats
SATARA, MAHARASHTRA
Rural Development Department
SAMASTIPUR, BIHAR
Rural Development Department
SAMASTIPUR, BIHAR
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| GENERIC | Height of High Mast Tower (in Meters) | 16 |
| GENERIC | Installation and commissioning (Installation and commissioning work at multiple locations shall follow as per the guidelines of State/Central Govt rules and regulations as applicable) | Yes. Including Civil work at site |
| GENERIC | Onsite warranty (in Years) | 5 |
| High mast System | No of sections | 2 |
| High mast System | Effective length of each section (in m) | 8.5 |
| High mast System | Material construction: The mast shall be manufactured using special steel plates, conforming to | 355 gradeasper BSEN10 025 |
| High mast System | Bottom diameter (in mm) - Minimum | 540 |
| High mast System | Plate thickness for Middle (in mm) - Minimum | 4 |
| High mast System | Plate thickness for Bottom (in mm) - Minimum | 5 |
| High mast System | No of longitudinal welds / section (in Nos) | 2 |
| High mast System | Diameter of base plate (in mm) - Minimum | 740 |
| High mast System | Thickness of base plate (in mm) - Minimum | 25 |
| Wind Load | Maximum Wind load | 50 m/sec |
| Door Opening | Size of opening and closing door at base compartment of high mast (in mm) - Minimum | 1200 x 250 |
| Junction Box | Ingress protection for Junction Box i.e. IP Class (as per IS/IEC:60529:2001 latest) Test Report from Central Government lab/NABL/ILAC accrediated lab and report shall furnish to buyer on demand | IP 65 |
| Junction Box | No of core | 3 |
| Junction Box | Cable category | FR-LSH |
| Junction Box | Size of cable (in Sq mm) | 2.5 |
| Junction Box | Conductor material shall be | Copper |
| Winch | The winch shall have provision for manual operation in case of failure of the motor | Yes |
| Stainless Steel Wire Rope | The breaking load of each rope shall be at full load as per the relevant standard | >/=2400 Kg |
| Electrical System, Cable and Cable Connections | No. of cores | 3 |
| Electrical System, Cable and Cable Connections | Cable shall be | Unarmoured |
| Electrical System, Cable and Cable Connections | Conudctor material shall be | Copper |
| Electrical System, Cable and Cable Connections | Cable Category | 1 |
| Electrical System, Cable and Cable Connections | Incoming power cable from feeder panel to base compartment of mast and cable shall conforming to | IS:7098 (Part 1):1988 latest |
| Feeder pillar Panel | Feeder pillar panel for each mast | Yes |
| Feeder pillar Panel | Feeder panel shall be suitable for | 415 V, 3 phase, 4 wire, 50 Hz, AC |
| Feeder pillar Panel | The control panels shall be | Stand mounted |
| Feeder pillar Panel | Ingress protection for feeder pillar panel i.e IP Class (as per IS/IEC:60529:2001 latest).Test Report shall furnish from Central Government lab/NABL/ILAC accrediated lab to buyer on demand | IP 65 |
| Feeder pillar Panel | It shall be fabricated out of | 14 SWG CRCA sheet steel |
| Feeder pillar Panel | Thickness of sheet (in mm) | 2 |
| Feeder pillar Panel | The panels shall be given pre-treatment and powder coated and color shall be | Grey |
| Feeder pillar Panel | The stand shall be painted in | Black color |
| Feeder pillar Panel | Cable entry shall be at the | Bottom |
| Feeder pillar Panel | The panels shall have | knock outs of the required cable |
| Feeder pillar Panel | Laminated circuit diagram shall be pasted | inside of the door |
| Feeder pillar Panel | Feeder pillar shall have pad locking arrangement | Yes |
| Feeder pillar Panel | Earth terminal | 12 mm dia. Bolts |
| Feeder pillar Panel | Panel shall have a sloping cover to avoid accumulation of dust | Yes |
| Feeder pillar Panel | Panel shall be provided with incoming & outgoing MCCB / MCB of appropriate rating and in desired quantity depending on total no of circuits in use | yes |
| Feeder pillar Panel | Timer for automatic ON & OFF of lights with pilot lamps shall be provided | Yes |
| Feeder pillar Panel | Bus bars material | Yes. Copper |
| Feeder pillar Panel | No of Cores | 3 |
| Feeder pillar Panel | Size of cable (in Sq.mm) | 2.5 |
| Feeder pillar Panel | Cable Shall be | Unarmoured |
| Feeder pillar Panel | The conductor material shall be | Copper |
| Feeder pillar Panel | cable category | 1 |
| LED FLOOD LIGHT LUMINAIRE | No. of Luminaires for each high mast lighting tower (in Nos) | 8 |
| LED FLOOD LIGHT LUMINAIRE | LED Rating/System Wattage/Rated Power for each luminaire | 400W |
| LED FLOOD LIGHT LUMINAIRE | Luminaire System Efficacy (Lumen/watt) | >/= 100 Lm/Watt |
| LED FLOOD LIGHT LUMINAIRE | Ingress Protection (IP Rating) as per IS:10322 (Part 1):1982 latest | IP65 |
| LED FLOOD LIGHT LUMINAIRE | Mounting brackets (included) | Adjustable |
| LED FLOOD LIGHT LUMINAIRE | Input operating Voltage range and frequency | 90 to 300 Volts AC at 50Hz+/-2Hz |
| LED FLOOD LIGHT LUMINAIRE | Rated voltage | 230 V AC 50 Hz |
| LED FLOOD LIGHT LUMINAIRE | Colour temperature | 6000K (+/- 500K) |
| LED FLOOD LIGHT LUMINAIRE | Optic lense material (UV stabilised) (Write NA for without optic lense supply) | Poly carbonate lense |
| LED FLOOD LIGHT LUMINAIRE | Operating temperature range | -20 deg C to +50 deg C |
| LED FLOOD LIGHT LUMINAIRE | The luminaire shall be protected against surges and transients( Internal) | >/=5KV |
| LED FLOOD LIGHT LUMINAIRE | Number of electronic control gear per luminaire (power supplies) | 1 No. |
| LED FLOOD LIGHT LUMINAIRE | Length of ISI marked three core wire (shall be provided along with supply of material) | 50 cm |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Additional Doc 1 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
The Fertilisers And Chemicals Travancore Limited
📍 ERNAKULAM, KERALA
Indian Air Force
📍 NAGPUR, MAHARASHTRA
Hqids
📍 SOUTH ANDAMAN, ANDAMAN & NICOBAR
Indian Army
📍 BHARATPUR, RAJASTHAN
All India Institute Of Medical Sciences (aiims)
📍 NADIA, WEST BENGAL
Sign up now to access all documents
Main Document
CATALOG Specification
GEM_GENERAL_TERMS_AND_CONDITIONS