SCR FULL CONTROLLER CARD PCB NO 052R1 CE,MODULE 52RA6,ELECTRO CAPSCREW 50mm 2500MFD 200VDC,CLAMP FO
Hindustan Petroleum Corporation Ltd
EAST GODAVARI, ANDHRA PRADESH
Bid Publish Date
02-Jul-2026, 1:14 pm
Bid End Date
17-Jul-2026, 2:00 pm
Value
₹2,77,000
Location
Progress
Quantity
22
Category
RESTNC BOX 5.5KW RV185VAC
Bid Type
Two Packet Bid
Organization: Uttar Pradesh Rajya Vidyut Utpadan Nigam Limited (uprvunl) Lucknow. Procurement: assortment of electrical products including RESTNC BOX 5.5KW RV185VAC, RESISTANCE BOX 26KW RV305VAC, POWER CENTER modules (MCE15N AC3 140AMP CV110VAC, CE15DN3AB10NAC3 3NO1NC, AUX CNTR CE15DN3BB10NAC3 3NO1NC CV230VAC, AUX CNTR D15 CR22A N 2NO plus 2NCCV110VAC), BI METALLIC OLR variants (1.6/8/70-95A), among 11 total items. Estimated value: ₹277,000. Location: Lucknow, Uttar Pradesh. Context: energy department procurement for electrical control and protection equipment; multiple item types imply a comprehensive electrical retrofit/upgrade scope. Key differentiator: diverse control/relay assemblies with AC/DC specification coverage and potential delivery flexibility per option clause. Unique aspects include a bundled electrical hardware assortment under a single tender and a 25% quantity variation option.
Quantity variation allowed up to 25% during procurement and contract currency with adjusted delivery times
Delivery schedule must follow calculated extension formula; minimum 30 days for any extension
ATC file uploaded; bidders must follow buyer-specified terms and provide required technical docs
Not specified in available data; bidders should verify ATC document for payment schedule and milestones
Delivery period extends based on (additional quantity ÷ original quantity) × original delivery period with minimum 30 days
Not specified in provided terms; check ATC for LD provisions if any
Experience in supplying electrical power control and protection equipment
Demonstrated capability to handle multi-item electrical procurement
Compliance with buyer-specified option clause and delivery computations
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
RESTNC BOX 5.5KW RV185VAC , 24040907 RESISTANCE BOX 1.5KW RV115VAC , POWR CNTR MCE15N AC3 140AMP CV110VAC , 2404050214 CNTR CE15DN3AB10NAC3 3NO1NC , AUX CNTR CE15DN3BB10NAC3 3NO1NC CV230VAC , AUX CNTR D15 CR22A N 2NO plus 2NCCV110VAC , 24040504 POWR CNTR CE15HN3 B1 AC3 CV110V , 24040607 BI METALLIC OLR SPP 1.6 2.5Amp , 24040607 BI METALIC OLR SPP 8 12.5Amp , 24040607 BI METALIC OLR 70 95Amp , 24040907 RESISTANCE BOX 26KW RV305VAC
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
BOQ
BOQ
OTHER
GEM_GENERAL_TERMS_AND_CONDITIONS
Hindustan Petroleum Corporation Ltd
EAST GODAVARI, ANDHRA PRADESH
Eastern Coalfields Limited
BARDHAMAN, WEST BENGAL
Nmdc Limited
DANTEWADA, CHHATTISGARH
Rourkela Steel Plant
SUNDERGARH, ODISHA
Ntpc Limited
SUNDERGARH, ODISHA
Tender Results
Loading results...
RESTNC BOX 5.5KW RV185VAC
RESISTANCE BOX 5.5 KW, RV 185 V AC S.S. FORMED GRID RATING 10 MINUTES.Resistance box rated 5.5 kW, 185 V AC, 50 Hz, short time duty 10 minutes, stainless steel SS304 formed grid type. Approx. current 30 A, resistance value as per design with 5percent tolerance. Natural oblicforced air cooled, suitable for intermittent duty, max element temperature up to 350 degree C Enclosure MS oblic SS, IP20 IP54, with ceramic insulation, heavy duty terminals, and earthing provision. Conforming to IEC 60115 4, IEC 60529, and IEC 60068.
24040907 RESISTANCE BOX 1.5KW RV115VAC
RESISTANCE BOX 1.5 KW, RV 115 V AC S.S. WIRE GRID RATING 10 MINUTES.Resistance box rated 1.5 kW, 115 V AC, 50 Hz, short time duty 10 minutes, stainless steel wire grid type. Approx. current 13 A, resistance value as per design with 5percent tolerance. Natural air cooled, suitable for intermittent duty, max element temperature up to 300 to 350degree C . Enclosure MS oblicSS, IP20 IP54, with ceramic insulation, terminals, and proper earthing. Conforming to IEC 60115 4, IEC 60529, and IEC 60068
POWR CNTR MCE15N AC3 140AMP CV110VAC
Heavy Duty Power Contactor MCE15N AC 3, COIL VOLTAGE 110 VOLT 50 Hz , 140Amp, 75KW BCH MAKE
2404050214 CNTR CE15DN3AB10NAC3 3NO1NC
AUXILARY Contactor CE15DN3AB10 N AC3,3 NO plus 1NC COIL VOLTAGE 110 VOLT 50 Hz , 16Amp.7.5 KW BCH MAKE
AUX CNTR CE15DN3BB10NAC3 3NO1NC CV230VAC
AUXILARY Contactor CE15DN3BB.10 N, 3NO plus 1NC COIL VOLTAGE 220 V AC BCH MAKE
AUX CNTR D15 CR22A N 2NO plus 2NCCV110VAC
AUXILARY Contactor D15 CR 22A N 2NO plus 2 NC,COIL VOLTAGE 110 VOLT 50 Hz BCH MAKE
24040504 POWR CNTR CE15HN3 B1 AC3 CV110V
POWER Contactor CE15 HN3 Series B1 AC3,COIL VOLTAGE 110 VOLT 50 Hz 50Amp.25 KW BCH MAKE
24040607 BI METALLIC OLR SPP 1.6 2.5Amp
Bi metallic OLR with SPP 1.6 2.5 Amp BCH OR SIEMENS
24040607 BI METALIC OLR SPP 8 12.5Amp
Bi metalic OLR with SPP 8 12.5 Amp Make Siemens,BCH
24040607 BI METALIC OLR 70 95Amp
Bi metalic OLR 70 95 Amp Make Siemens,BCH
24040907 RESISTANCE BOX 26KW RV305VAC
RESISTANCE BOX 26 KW, RV 305 V AC S.S. FORMED GRID RATING 10 MINUTES.Resistance box rated 26 kW, 305 V AC, 50 Hz, short time duty 10 minutes, stainless steel SS304 formed grid type. Approx. current 85 A, resistance value as per design with 5percent tolerance. Natural oblicforced air cooled, max element temp up to 350 degree C, suitable for intermittent duty. Enclosure MS oblicSS, IP20 to IP54, with ceramic insulation, bolted terminals, and earthing provision. Conforming to IEC 60115 4, IEC 60529, and IEC 60068 with routine electrical tests
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) | Price Trends |
|---|---|---|---|---|---|---|---|
| 1 | RESTNC BOX 5.5KW RV185VAC | RESISTANCE BOX 5.5 KW, RV 185 V AC S.S. FORMED GRID RATING 10 MINUTES.Resistance box rated 5.5 kW, 185 V AC, 50 Hz, short time duty 10 minutes, stainless steel SS304 formed grid type. Approx. current 30 A, resistance value as per design with 5percent tolerance. Natural oblicforced air cooled, suitable for intermittent duty, max element temperature up to 350 degree C Enclosure MS oblic SS, IP20 IP54, with ceramic insulation, heavy duty terminals, and earthing provision. Conforming to IEC 60115 4, IEC 60529, and IEC 60068. | 2 | ea | ee_pd1_parichha | 90 | |
| 2 | 24040907 RESISTANCE BOX 1.5KW RV115VAC | RESISTANCE BOX 1.5 KW, RV 115 V AC S.S. WIRE GRID RATING 10 MINUTES.Resistance box rated 1.5 kW, 115 V AC, 50 Hz, short time duty 10 minutes, stainless steel wire grid type. Approx. current 13 A, resistance value as per design with 5percent tolerance. Natural air cooled, suitable for intermittent duty, max element temperature up to 300 to 350degree C . Enclosure MS oblicSS, IP20 IP54, with ceramic insulation, terminals, and proper earthing. Conforming to IEC 60115 4, IEC 60529, and IEC 60068 | 1 | ea | ee_pd1_parichha | 90 | |
| 3 | POWR CNTR MCE15N AC3 140AMP CV110VAC | Heavy Duty Power Contactor MCE15N AC 3, COIL VOLTAGE 110 VOLT 50 Hz , 140Amp, 75KW BCH MAKE | 2 | ea | ee_pd1_parichha | 90 | |
| 4 | 2404050214 CNTR CE15DN3AB10NAC3 3NO1NC | AUXILARY Contactor CE15DN3AB10 N AC3,3 NO plus 1NC COIL VOLTAGE 110 VOLT 50 Hz , 16Amp.7.5 KW BCH MAKE | 2 | ea | ee_pd1_parichha | 90 | |
| 5 | AUX CNTR CE15DN3BB10NAC3 3NO1NC CV230VAC | AUXILARY Contactor CE15DN3BB.10 N, 3NO plus 1NC COIL VOLTAGE 220 V AC BCH MAKE | 1 | ea | ee_pd1_parichha | 90 | |
| 6 | AUX CNTR D15 CR22A N 2NO plus 2NCCV110VAC | AUXILARY Contactor D15 CR 22A N 2NO plus 2 NC,COIL VOLTAGE 110 VOLT 50 Hz BCH MAKE | 3 | ea | ee_pd1_parichha | 90 | |
| 7 | 24040504 POWR CNTR CE15HN3 B1 AC3 CV110V | POWER Contactor CE15 HN3 Series B1 AC3,COIL VOLTAGE 110 VOLT 50 Hz 50Amp.25 KW BCH MAKE | 1 | ea | ee_pd1_parichha | 90 | |
| 8 | 24040607 BI METALLIC OLR SPP 1.6 2.5Amp | Bi metallic OLR with SPP 1.6 2.5 Amp BCH OR SIEMENS | 3 | ea | ee_pd1_parichha | 90 | |
| 9 | 24040607 BI METALIC OLR SPP 8 12.5Amp | Bi metalic OLR with SPP 8 12.5 Amp Make Siemens,BCH | 2 | ea | ee_pd1_parichha | 90 | |
| 10 | 24040607 BI METALIC OLR 70 95Amp | Bi metalic OLR 70 95 Amp Make Siemens,BCH | 4 | ea | ee_pd1_parichha | 90 | |
| 11 | 24040907 RESISTANCE BOX 26KW RV305VAC | RESISTANCE BOX 26 KW, RV 305 V AC S.S. FORMED GRID RATING 10 MINUTES.Resistance box rated 26 kW, 305 V AC, 50 Hz, short time duty 10 minutes, stainless steel SS304 formed grid type. Approx. current 85 A, resistance value as per design with 5percent tolerance. Natural oblicforced air cooled, max element temp up to 350 degree C, suitable for intermittent duty. Enclosure MS oblicSS, IP20 to IP54, with ceramic insulation, bolted terminals, and earthing provision. Conforming to IEC 60115 4, IEC 60529, and IEC 60068 with routine electrical tests | 1 | ea | ee_pd1_parichha | 90 |
Discover companies most likely to bid on this tender
GST registration certificate
PAN card
Experience certificates for similar electrical equipment supply
Financial statements (last 2-3 years)
EMD/Security deposit details (if applicable; amount not disclosed)
Technical bid documents and compliance certificates (as per ATC)
OEM authorization or dealership/agency certificates for specified components
Key insights about UTTAR PRADESH tender market
Bidders should submit GST, PAN, experience certificates, financial statements, EMD details (if applicable), and the ATC-compliant technical bid. Ensure compliance with the option clause allowing ±25% quantity changes and use the delivery-time formula. Reference the uploaded ATC for specific terms.
Required documents include GST registration, PAN, experience certificates for similar supply, financial statements for the last 2-3 years, EMD details (if applicable), ATC-compliant technical bid, and OEM authorizations for listed components such as RESTNC BOX and POWER CENTER modules.
Technical context includes AC3 140A rating for CV110VAC controls and 230VAC auxiliary relays CE15DN3BB10NAC3 with 3NO/1NC configurations. Ensure bidding against exact model numbers and cross-check the ATC document for any firmware or compatibility standards.
The tender has an estimated value of ₹277,000, covering 11 electrical items including RESTNC BOX, RESISTANCE BOX, and various POWER CENTER units. Bid submissions should reflect unit-wise pricing aligned to the cataloged items and possible quantity variations.
Quantity variation is allowed up to ±25% of the bid quantity at contract placement and during the contract currency, with delivery time adjustments based on a defined calculation ensuring minimum 30 days extension.
While explicit standards aren’t listed in the provided data, bidders should consult the ATC for required certifications, OEM authorizations, and compliance to electrical component norms. Ensure you have valid GST, PAN, and relevant experience certificates as a baseline.
Delivery terms rely on the option clause with calculated extension times; the minimum extension is 30 days. Penalty details (LD) are not specified in the available data and must be confirmed in the ATC to avoid non-compliance.
Access the uploaded ATC document linked with the tender to verify compliance requirements, technical specifications, eligibility criteria, and any special clauses. Cross-check item numbers against the BOQ and confirm OEM authorizations for listed components.
Uttar Pradesh Rajya Vidyut Utpadan Nigam Limited (uprvunl) Lucknow
📍 JHANSI, UTTAR PRADESH
N/a
📍 BULANDSHAHR, UTTAR PRADESH
Uttar Pradesh Rajya Vidyut Utpadan Nigam Limited (uprvunl) Lucknow
📍 JHANSI, UTTAR PRADESH
Uttar Pradesh Rajya Vidyut Utpadan Nigam Limited (uprvunl) Lucknow
📍 SONBHADRA, UTTAR PRADESH
N/a
📍 BULANDSHAHR, UTTAR PRADESH
Sign up now to access all documents
Main Document
BOQ
BOQ
OTHER
GEM_GENERAL_TERMS_AND_CONDITIONS