Air-Conditioner,Stabilizers,Ceiling -fan,Water-purifier(RO) with water-cooler,Inverter1KVA with Bat
Combined Admission System (cas), Department Of Medical Health & Family Welfare, Uttar Pradesh
RAMPUR, UTTAR PRADESH
Bid Publish Date
10-Jul-2026, 4:19 pm
Bid End Date
25-Jul-2026, 5:00 pm
Location
Progress
Quantity
72
Category
Air Conditioner for CCTV Control Room to maintain adequate Temperature
Bid Type
Two Packet Bid
A tender has been published for Directorate Of Medical Education And Research Air Conditioner for CCTV Control Room to maintain adequate Temperature, PWM & IGBT based, 3kVA capacity online, , Tubular Battery, 12V/150Ah, Online Ups Modular Type in OSMANABAD, MAHARASHTRA. Quantity: 72 by. Submission Deadline: 25-07-2026 17: 00: 00. Check eligibility and apply.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
Air Conditioner for CCTV Control Room to maintain adequate Temperature , PWM & IGBT based, 3kVA capacity online, , Tubular Battery, 12V/150Ah , Online Ups Modular Type
Max Delivery Days
15
Delivery Locations
1
Delivery Cities
Osmanabad
Delivery Pincodes
413501
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| Shashikant Popatrao Ankushe | 413501,Civil Hospital Campus, Marwad galli, Osmanabad | Osmanabad | Maharashtra | 413501 | 1 | 15 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
OTHER
OTHER
OTHER
CATALOG Specification
GEM_GENERAL_TERMS_AND_CONDITIONS
Combined Admission System (cas), Department Of Medical Health & Family Welfare, Uttar Pradesh
RAMPUR, UTTAR PRADESH
Bharat Sanchar Nigam Limited Portal(bsnl)
CHANDIGARH, CHANDIGARH
Employees State Insurance Corporation
Public Works Department
WEST, DELHI
Employees State Insurance Corporation
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| GENERIC | Output power capacity including redundancy/Expandable (Rack facility) upto/Minimum backuptime (including redundancy) /Minimum VAH (VAH shall be calculated Battery voltage x Battery Ah x No. of batteries = Total VAH) | 4KVA/8KVA/6 minutes/1080 VAH |
| GENERIC | Noise level | |
| INPUT | In put Voltage Range | 320 V to AC to 470 V AC 3 Phase |
| INPUT | Input frequency range | 50 +/-10% Hz |
| INPUT | Distortion (current) | < / = 3% |
| OUTPUT | Output powr factor | >/=0.99 |
| CONSTRUCTION | Minimum thickness (in mm) of Rack Enclosure for Modular UPS duly powder coated | 1.2 |
| CONSTRUCTION | UPS enclosure's degree of protection as per IS:13947 (Part 1)/1993 latest | IP20 |
| CONSTRUCTION | Total Harmonic Distrotion (THD) for 100% linear load | < 2% |
| CONSTRUCTION | Total Harmonic Distrotion (THD) for 100% non-linear load | < 5% |
| CONSTRUCTION | Over all efficiency on rated full load of 0.8 PF (min.) AC output | >/=96% |
| CONSTRUCTION | Inverter efficiency on rated full load of 0.8 PF (min.) AC output | >/=95% |
| CONSTRUCTION | UPS shall withstand Over load capacity - 125% (Output with mains AC-AC) | for 5 Minutes (Minimum) |
| CONSTRUCTION | UPS shall withstand Over load capacity - 125% (Output in battery run DC-AC) | for 2 Minutes (Minimum) |
| BATTERY | Battery type | SMF VRLA |
| BATTERY | Battery recharge time (after complete discharge to 90% charge) and charge rating: Battery recharge time to 90% charge after 100% DoD | 8 to 10 hours |
| BATTERY | Batteries shall supply with | With metal rack |
| WARRANTY AND SERVICES | Warranty for Modular UPS (on site comprehensive warranty) (in years) | 3 |
| WARRANTY AND SERVICES | Warranty for battery (replacement warranty) (in years) | 2 |
| WARRANTY AND SERVICES | After sales and complaint service | within 48 hours |
| WARRANTY AND SERVICES | PAN India service support on 24 x 7 basis | Yes |
| WARRANTY AND SERVICES | AMC support available after 3 year warranty | Yes |
| WARRANTY AND SERVICES | Quarterly preventive maintenance | Yes |
| WARRANTY AND SERVICES | Manufacturer shall provide and support for installation, commissioning, spares, technical support all over India | Yes |
| WARRANTY AND SERVICES | Availability of spares in close proximity (Spares should be easily available close to the site) | Yes |
| CERTIFICATIONS | CE Certification and marking | Yes |
| CERTIFICATIONS | Damp Heat Test : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C,two cycles of (12+12) hours each 2007) | Yes |
| CERTIFICATIONS | Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs | Yes |
| CERTIFICATIONS | Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. | Yes |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Indian Army
📍 Sri Ganganagar, RAJASTHAN
North Eastern Regional Institute Of Water And Land Management (neriwalm)
📍 SONITPUR, ASSAM
Indian Army
Indian Army
📍 JABALPUR, MADHYA PRADESH
Indian Army
📍 MAINPURI, UTTAR PRADESH
Sign up now to access all documents
Main Document
OTHER
OTHER
OTHER
CATALOG Specification
GEM_GENERAL_TERMS_AND_CONDITIONS