SPECTROPHOTOMETER
Rajiv Gandhi Centre For Biotechnology (rgcb)
THIRUVANANTHAPURAM, KERALA
Bid Publish Date
13-Jul-2026, 5:13 pm
Bid End Date
06-Aug-2026, 6:00 pm
EMD
₹10,000
Location
Progress
Quantity
1
Bid Type
Two Packet Bid
Uranium Corporation Of India Limited announces a tender for SPECTROPHOTOMETER (Q2) in EAST SINGHBHUM, JHARKHAND. Quantity: 1. Submission Deadline: 06-08-2026 18: 00: 00. Last date to apply is approaching fast!
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
SPECTROPHOTOMETER (Q2)
Advisory Bank
State Bank of India
ePBG Percentage
3%
ePBG Duration (Months)
18
Payment Timelines
Payments shall be made to the Seller within 10 days of issue of consignee receipt-cum-acceptance certificate (CRAC) and on-line submission of bills (This is in supersession of 10 days time as provided in clause 12 of GeM GTC)
Max Delivery Days
90
Delivery Locations
1
Delivery Cities
East Singhbum
Delivery Pincodes
832102
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| SUDIPTA DAS | 832102,UCIL JADUGUDA STORE CHIEF SUPERINTENDENT STORE AT/PO-JADUGUDA MINES MAIN BUILDING URANIUM CORPORATION OF INDIA LTD Ph No : 9431139916 | East Singhbum | Jharkhand | 832102 | 1 | 90 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
OTHER
GEM_GENERAL_TERMS_AND_CONDITIONS
Rajiv Gandhi Centre For Biotechnology (rgcb)
THIRUVANANTHAPURAM, KERALA
N/a
N/a
Government Colleges Of Madhya Pradesh
Government Colleges Of Madhya Pradesh
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| LIGHT SOURCE | Light Source | Xenon Flash |
| LIGHT SOURCE | Diffraction Grating (lines/mm) | 1000 |
| LIGHT SOURCE | Switching of Light Source | Automatic |
| LIGHT SOURCE | Wavelength Setting And Scanning | Automatic |
| TYPE | Type of Spectrophotometer | UV - VISIBLE |
| TYPE | Type of Optical System | Double Beam |
| TYPE | Monochromator Type | NA |
| TYPE | Detector Type | Photodiode |
| TYPE | Spectral Bandwidth Type | Fixed Bandwidth |
| OPTICAL PERFORMANCE | Source Wavelength - Minimum | 200.0 |
| OPTICAL PERFORMANCE | Source Wavelength - Maximum | 1100, 1500, 2000, 2500, 2700, 3000, 3200, 3300, 1650 Or higher |
| OPTICAL PERFORMANCE | Resolution | 1.0 |
| OPTICAL PERFORMANCE | Wavelength Accuracy (+/-) | 1.0 |
| OPTICAL PERFORMANCE | Bandwidth (nm) | 2.0 |
| OPTICAL PERFORMANCE | If variable band width, Specify the incremental step value(mm) | 1.0, NA |
| OPTICAL PERFORMANCE | Scanning Speed (nm/min) | 1800 |
| OPTICAL PERFORMANCE | Focal length (mm) | 0 to 49 |
| OPTICAL PERFORMANCE | Photometric measurement modes | Absorbance |
| OPTICAL PERFORMANCE | Photometric Absorbance (Max) (Abs) (+/-) | 4 |
| OPTICAL PERFORMANCE | Photometric Absorbance Accuracy (Max) (+/-) | 0.001 - 0.001 Or lower |
| OPTICAL PERFORMANCE | Photometric Transmittance (Max) (+/-) | 100.0 |
| OPTICAL PERFORMANCE | Photometric Transmittance Accuracy (Max) (+/-) | 0.0 - 0.0 Or lower |
| OPTICAL PERFORMANCE | Photometric Reflectance (Max) (+/-) | 100.0 |
| OPTICAL PERFORMANCE | Photometric Reflectance Accuracy (Max) (+/-) | 0.0 - 0.5 Or lower |
| OPTICAL PERFORMANCE | Stray Light Correction | Automatic |
| OPTICAL PERFORMANCE | Baseline Correction | Automatic |
| GENERIC | Display | In-built display |
| GENERIC | Display type | LCD touchscreen |
| GENERIC | Display Size | 7.0 - 30.0 Or higher |
| GENERIC | Test result printing | Through external printer |
| GENERIC | If inbuilt printer, Type of printer | N/A |
| GENERIC | Suitable software for connecting PC & Printer | N/A |
| GENERIC | Connectivity | USB |
| GENERIC | Internal storage(GB) | 80.0 - 80.0 Or higher |
| GENERIC | Sample switching/selection | Automatic |
| GENERIC | Capacity of Sample holder / Sample Carousel | 8 |
| GENERIC | Mximum Path Length of sample | 10.0 |
| GENERIC | Number of Cuvettes supplied-inclusive in the scope of supply | 0 |
| GENERIC | Power Supply | 230 V ± 10, 50 Hz |
| GENERIC | Spares and Consumables inclusive in the scope of supply | No |
| OPERATING CONDITIONS | Minimum Operating Temperature | 10.0 |
| OPERATING CONDITIONS | Maximum Operating Temperature | 40.0 |
| OPERATING CONDITIONS | Operating Humidity (RH) (%) at 40 degree C | 85.0 |
| WARRANTY | Onsite Warranty | 1.0 |
| WARRANTY | Availability of Spares (at extra cost) | 2.0 |
| Certification | Availability of UL/CE Certification as per EN 61010-1:2010 Safety requirements for electrical equipment for measurement, control, and laboratory use General requirements | Yes |
| Certification | Conformance to EMC/EMI as per EN 61326-1:2013 Electrical equipment for measurement, control and laboratory use | Yes |
| Certification | Availability of Test Reports from Central Govt / NABL approved / ILAC acredited lab to prove conformity to the specification | No |
| Certification | If yes test report to furnished,to the buyer on demand | N/A |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Annual Turnover *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Regional Centre For Biotechnology (rcb) Gurgaon
📍 FARIDABAD, HARYANA
Kamdhenu University
📍 SABARKANTHA, GUJARAT
Gujarat Technological University Ahmedabad
📍 MAHESANA, GUJARAT
Kamdhenu University
📍 JAMNAGAR, GUJARAT
Sher-e-kashmir University Of Agricultural Sciences And Technology Of Jammu
📍 JAMMU, JAMMU & KASHMIR
Sign up now to access all documents
Main Document
CATALOG Specification
OTHER
GEM_GENERAL_TERMS_AND_CONDITIONS