SPECTROPHOTOMETER
Kamdhenu University
ANAND, GUJARAT
Bid Publish Date
01-Jul-2026, 2:51 pm
Bid End Date
16-Jul-2026, 3:00 pm
Value
₹2,50,000
Location
Progress
Quantity
2
Bid Type
Two Packet Bid
Public procurement opportunity for Kamdhenu University SPECTROPHOTOMETER (Q2) in SABARKANTHA, GUJARAT. Quantity: 2 issued by. Submission Deadline: 16-07-2026 15: 00: 00. View full details and respond.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
SPECTROPHOTOMETER (Q2)
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Kamdhenu University
ANAND, GUJARAT
Rajiv Gandhi Centre For Biotechnology (rgcb)
THIRUVANANTHAPURAM, KERALA
Department Of Drugs Control
Indian Institutes Of Science Education And Research (iiser)
GANJAM, ODISHA
N/a
JAUNPUR, UTTAR PRADESH
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| LIGHT SOURCE | Light Source | Deuterium Lamp, Tungsten Halogen Lamp |
| LIGHT SOURCE | Diffraction Grating (lines/mm) | 1200 |
| LIGHT SOURCE | Switching of Light Source | Automatic |
| LIGHT SOURCE | Wavelength Setting And Scanning | Automatic |
| TYPE | Type of Spectrophotometer | UV - VISIBLE |
| TYPE | Type of Optical System | Single Beam |
| TYPE | Monochromator Type | Holographic Grating |
| TYPE | Detector Type | Photodiode |
| TYPE | Spectral Bandwidth Type | Fixed Bandwidth |
| OPTICAL PERFORMANCE | Source Wavelength - Minimum | 200.0 |
| OPTICAL PERFORMANCE | Source Wavelength - Maximum | 1100, 1500, 2000, 2500, 2700, 3000, 3200, 3300, 1650 Or higher |
| OPTICAL PERFORMANCE | Resolution | 0.002, 0.3, 0.5, 1, 1.25, 1.5, 1.7, 2, 0.2, 0.01 |
| OPTICAL PERFORMANCE | Wavelength Accuracy (+/-) | 0.5 |
| OPTICAL PERFORMANCE | Bandwidth (nm) | 0.1, 0.2, 0.5, 1, 1.5, 1.8, 2.0, 4.0, 5.0, 0.1 to 5.0, 7, 8.5 |
| OPTICAL PERFORMANCE | If variable band width, Specify the incremental step value(mm) | 1.0, NA |
| OPTICAL PERFORMANCE | Focal length (mm) | 0 to 49, 50 to 99, 100 to 149, 150 to 199, 200 to 249, 250 to 299, 300 and above |
| OPTICAL PERFORMANCE | Photometric measurement modes | Transmittance, Absorbance, Concentration (Wavelength, time) |
| OPTICAL PERFORMANCE | Photometric Absorbance (Max) (Abs) (+/-) | 0.2 - 8 |
| OPTICAL PERFORMANCE | Photometric Absorbance Accuracy (Max) (+/-) | 0.001 - 0.5 |
| OPTICAL PERFORMANCE | Photometric Transmittance (Max) (+/-) | 100.0 |
| OPTICAL PERFORMANCE | Photometric Transmittance Accuracy (Max) (+/-) | 0 - 0.5 |
| OPTICAL PERFORMANCE | Photometric Reflectance (Max) (+/-) | 0 - 100 |
| OPTICAL PERFORMANCE | Stray Light Correction | Automatic |
| OPTICAL PERFORMANCE | Baseline Correction | Automatic |
| GENERIC | Display | In-built display |
| GENERIC | Display type | LCD with Backlight |
| GENERIC | Display Size | 0 - 30 |
| GENERIC | Test result printing | Through external printer |
| GENERIC | If inbuilt printer, Type of printer | N/A |
| GENERIC | Suitable software for connecting PC & Printer | Yes |
| GENERIC | Connectivity | USB |
| GENERIC | Internal storage(GB) | 0 - 80 |
| GENERIC | Sample switching/selection | Automatic |
| GENERIC | Capacity of Sample holder / Sample Carousel | 2, 4 |
| GENERIC | Mximum Path Length of sample | 10.0 |
| GENERIC | Number of Cuvettes supplied-inclusive in the scope of supply | 2 |
| GENERIC | Power Supply | 230 V ± 10, 50 Hz |
| GENERIC | Spares and Consumables inclusive in the scope of supply | Yes, No |
| OPERATING CONDITIONS | Minimum Operating Temperature | 5.0 |
| OPERATING CONDITIONS | Maximum Operating Temperature | 45.0 |
| OPERATING CONDITIONS | Operating Humidity (RH) (%) at 40 degree C | 80.0 |
| WARRANTY | Onsite Warranty | 1.0 |
| WARRANTY | Availability of Spares (at extra cost) | 2, 3, 4, 5, 6, 7, 8, 10 |
| Certification | Availability of UL/CE Certification as per EN 61010-1:2010 Safety requirements for electrical equipment for measurement, control, and laboratory use General requirements | Yes, No |
| Certification | Conformance to EMC/EMI as per EN 61326-1:2013 Electrical equipment for measurement, control and laboratory use | Yes, No |
| Certification | Availability of Test Reports from Central Govt / NABL approved / ILAC acredited lab to prove conformity to the specification | Yes, No |
| Certification | If yes test report to furnished,to the buyer on demand | N/A |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Additional Doc 1 (Requested in ATC)
Additional Doc 2 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Bihar Agricultural University
📍 BHAGALPUR, BIHAR
State Forensic Science Laboratory Chhattisgarh
📍 RAIPUR, CHHATTISGARH
Sher-e-kashmir University Of Agricultural Sciences And Technology Of Jammu
📍 JAMMU, JAMMU & KASHMIR
National Institute Of Technology (nit)
📍 HAMIRPUR, HIMACHAL PRADESH
Jawaharlal Institute Of Postgraduate Medical Education And Research (jipmer)
📍 PONDICHERRY, PUDUCHERRY
Sign up now to access all documents
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS