SPECTROPHOTOMETER
Rajiv Gandhi Centre For Biotechnology (rgcb)
THIRUVANANTHAPURAM, KERALA
Progress
Quantity
1
Bid Type
Two Packet Bid
Kamdhenu University invites bids for SPECTROPHOTOMETER (Q2) in JAMNAGAR, GUJARAT. Quantity: 1. Submission Deadline: 30-07-2026 13: 00: 00. Submit your proposal before the deadline.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
SPECTROPHOTOMETER (Q2)
Advisory Bank
State Bank of India
ePBG Percentage
5%
ePBG Duration (Months)
38
Payment Timelines
Payments shall be made to the Seller within 30 days of issue of consignee receipt-cum-acceptance certificate (CRAC) and on-line submission of bills (This is in supersession of 10 days time as provided in clause 12 of GeM GTC)
Max Delivery Days
15
Delivery Locations
1
Delivery Cities
Jamnagar
Delivery Pincodes
361140
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| Hitesh Kanji Kardani | 361140,Office of Research Officer, Fisheries Research Station, Kamdhenu University, Sikka, Dist. Jamnagar | Jamnagar | Gujarat | 361140 | 1 | 15 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
OTHER
GEM_GENERAL_TERMS_AND_CONDITIONS
Rajiv Gandhi Centre For Biotechnology (rgcb)
THIRUVANANTHAPURAM, KERALA
N/a
N/a
Government Colleges Of Madhya Pradesh
Government Colleges Of Madhya Pradesh
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| LIGHT SOURCE | Light Source | Deuterium Lamp, Tungsten Halogen Lamp |
| LIGHT SOURCE | Diffraction Grating (lines/mm) | 1200 |
| LIGHT SOURCE | Switching of Light Source | Automatic |
| LIGHT SOURCE | Wavelength Setting And Scanning | Automatic |
| TYPE | Type of Spectrophotometer | UV - VISIBLE |
| TYPE | Type of Optical System | Double Beam |
| TYPE | Monochromator Type | Czerny-turner |
| TYPE | Detector Type | Photodiode |
| TYPE | Spectral Bandwidth Type | Fixed Bandwidth |
| OPTICAL PERFORMANCE | Source Wavelength - Minimum | 190.0 |
| OPTICAL PERFORMANCE | Source Wavelength - Maximum | 1100, 1500, 2000, 2500, 2700, 3000, 3200, 3300, 1650 Or higher |
| OPTICAL PERFORMANCE | Resolution | 1.0 |
| OPTICAL PERFORMANCE | Wavelength Accuracy (+/-) | 0.1 |
| OPTICAL PERFORMANCE | Bandwidth (nm) | 1 |
| OPTICAL PERFORMANCE | Focal length (mm) | 0 to 49 |
| OPTICAL PERFORMANCE | Photometric measurement modes | Transmittance, Absorbance, Concentration (Wavelength, time), Reflectance, Energy |
| OPTICAL PERFORMANCE | Photometric Absorbance (Max) (Abs) (+/-) | 4 |
| OPTICAL PERFORMANCE | Photometric Absorbance Accuracy (Max) (+/-) | 0.001 - 0.002 Or lower |
| OPTICAL PERFORMANCE | Photometric Transmittance (Max) (+/-) | 100.0 |
| OPTICAL PERFORMANCE | Photometric Transmittance Accuracy (Max) (+/-) | 0.0 - 0.5 Or lower |
| OPTICAL PERFORMANCE | Photometric Reflectance (Max) (+/-) | 100.0 |
| OPTICAL PERFORMANCE | Photometric Reflectance Accuracy (Max) (+/-) | 0.0 - 0.002 Or lower |
| OPTICAL PERFORMANCE | Stray Light Correction | Automatic |
| OPTICAL PERFORMANCE | Baseline Correction | Automatic |
| GENERIC | Display | In-built display |
| GENERIC | Display type | LCD touchscreen |
| GENERIC | Display Size | 6.0 - 30.0 Or higher |
| GENERIC | Test result printing | Through external printer |
| GENERIC | If inbuilt printer, Type of printer | N/A |
| GENERIC | Suitable software for connecting PC & Printer | Yes |
| GENERIC | Connectivity | USB, WIFI, RS 232 |
| GENERIC | Internal storage(GB) | 32.0 - 80.0 Or higher |
| GENERIC | Mximum Path Length of sample | 100.0 |
| GENERIC | Number of Cuvettes supplied-inclusive in the scope of supply | 2 |
| GENERIC | Spares and Consumables inclusive in the scope of supply | No |
| OPERATING CONDITIONS | Minimum Operating Temperature | 10.0 |
| OPERATING CONDITIONS | Maximum Operating Temperature | 35.0 |
| OPERATING CONDITIONS | Operating Humidity (RH) (%) at 40 degree C | 80.0 |
| WARRANTY | Onsite Warranty | 1.0 |
| WARRANTY | Availability of Spares (at extra cost) | 7.0 |
| Certification | Availability of UL/CE Certification as per EN 61010-1:2010 Safety requirements for electrical equipment for measurement, control, and laboratory use General requirements | Yes |
| Certification | Conformance to EMC/EMI as per EN 61326-1:2013 Electrical equipment for measurement, control and laboratory use | Yes |
| Certification | Availability of Test Reports from Central Govt / NABL approved / ILAC acredited lab to prove conformity to the specification | No |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Additional Doc 1 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Kamdhenu University
📍 SABARKANTHA, GUJARAT
Gujarat Technological University Ahmedabad
📍 MAHESANA, GUJARAT
Regional Centre For Biotechnology (rcb) Gurgaon
📍 FARIDABAD, HARYANA
Sher-e-kashmir University Of Agricultural Sciences And Technology Of Jammu
📍 JAMMU, JAMMU & KASHMIR
Uranium Corporation Of India Limited
📍 EAST SINGHBHUM, JHARKHAND
Sign up now to access all documents
Main Document
CATALOG Specification
OTHER
GEM_GENERAL_TERMS_AND_CONDITIONS