Bunk Beds conforming to IS 17636
National Education Society For Tribal Students
KASARGOD, KERALA
Bid Publish Date
23-Jun-2026, 12:19 pm
Bid End Date
08-Jul-2026, 11:00 am
Location
Progress
Quantity
20
Bid Type
Two Packet Bid
N/a announces a tender for Bunk Beds conforming to IS 17636 (Q2) in EAST SIKKIM, SIKKIM. Quantity: 20. Submission Deadline: 08-07-2026 11: 00: 00. Last date to apply is approaching fast!
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
Bunk Beds conforming to IS 17636 (Q2)
End-to-end support โ bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation ยท 24h response
Main Document
CATALOG Specification
GEM_GENERAL_TERMS_AND_CONDITIONS
National Education Society For Tribal Students
KASARGOD, KERALA
N/a
ERNAKULAM, KERALA
Estate Office Kvafsu Bidar
GADAG, KARNATAKA
Commissionerate Of Tribal Development
SURAT, GUJARAT
Commissionerate Of Tribal Development
SURAT, GUJARAT
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| Generic Parameters | Type of bunk beds | 2 โ Tier bunk beds (Fixed) |
| Generic Parameters | Railing / guard rail at upper bed | Fixed, Detachable |
| Generic Parameters | Tail board | With |
| Generic Parameters | Shape of tail board | Rectangular |
| Generic Parameters | Head rest | With, Without |
| Generic Parameters | Shape of headrest | Rectangular |
| Generic Parameters | Provision for mosquito net holding rod | Fixed, Detachable, No mosquito net holding rod |
| Generic Parameters | Components assembly | By welding, With screws, bolt and washer |
| Generic Parameters | Type of welding | MIG (Metal inert gas - Gas Metal Arc Welding) |
| Generic Parameters | Provision of mattress panel | With, Without |
| Generic Parameters | Mode of supply | Knocked Down - To Be Assembled At Consignee Site By The Seller |
| Generic Parameters | Type of Surface upholstery | Fabric, Synthetic Leather, Natural Leather, NA |
| Dimensions | Bed Dimensions (Length x Width) (ยฑ5 mm) | Adult (1910 mm x 965 mm) |
| Dimensions | Height of entire structure (ยฑ5 mm) โ excluding Mosquito net holding rods (minimum ceiling clearance to be 760 mm) | 1600, 1752, 1775, 1800, 1950, 2000, 2073, 2438 |
| Dimensions | Height of lower tier (ยฑ5 mm) (Buyer should be careful while selecting keeping in mind minimum ceiling clearance as required ideally 760 mm minimum) | 460.0, 405.0 |
| Dimensions | Gap between beds (clear distance between the upper and lower bed bases in mm) (ยฑ 5 mm) | 750, 835, 850, 915, 1000, 1067 Or higher |
| Construction | Structure of metal bed frame including legs and head / tails / railing /supporting structure | MS hollow box rectangular or square sections, CRCA hollow box rectangular or square sections, Electric resistance welding (ERW) tube Confirming to IS 7138,, Wrought iron tube, SS 202 tube, SS 304 tube |
| Construction | Vertical leg structure sections (tolerance ยฑ 2 mm excluding wall thickness) | Tube of size 50 mm X 50 mm with 1.2 mm wall thickness, Tube of size 37.5 mm X 37.5 mm with 1.2 mm wall thickness, Tube of size 37.5 mm X 50 mm with 1.2 mm wall thickness, Tube of size 37.5 mm X 37.5 mm with 0.6 mm wall thickness (for SS), Tube of size 38.1 mm X 38.1 mm with 1.6 mm wall thickness, Tube of size 19.05 mm X 19.05 mm with 2 mm wall thickness |
| Construction | Supporting structure of horizontals sections (tolerance ยฑ 2 mm excluding wall thickness) | Tube of size 50 mm X 25 mm with 1.2 mm wall thickness, Tube of size 50 mm X 37.5 mm with 1.2 mm wall thickness, Tube of size 37.5 mm X 25 mm with 1.2 mm wall thickness, Tube of size 37.5 mm X 25 mm with 0.6 mm wall thickness(for SS), Tube of size 50.8 mm X 25.4 mm with 2 mm wall thickness |
| Construction | Other joining horizontal structure sections (tolerance ยฑ 2 mm excluding wall thickness) | Tube of size 25 mm X 25 mm with 1.2 mm wall thickness, Tube of size 25 mm X 25 mm with 0.6 mm wall thickness(for SS) |
| Construction | Stair rail sections for upper level (tolerance ยฑ 2 mm excluding wall thickness) | Tube of size 50 mm X 25 mm with 1.2 mm wall thickness, Tube of size 50 mm X 25 mm with 0.6 mm wall thickness(for SS), Tube of size 25 mm X 25 mm with 1.2 mm wall thickness |
| Construction | Stair step sections (tolerance ยฑ 2 mm excluding wall thickness) | Tube of size 25 mm X 25 mm with 1.2 mm wall thickness, Tube of size 25 mm X 25 mm with 0.6 mm wall thickness(for SS), Tube of size 19 mm X 19 mm with 1.2 mm wall thickness |
| Construction | Material of mattress panel | Plywood, Plywood oil painted, Commercial plywood, 20 gauge CRCA Steel sheet conforming to IS 513 (latest amendment), Pre-laminated particle board |
| Construction | Thickness of mattress panel | 18 mm Ply, 20 gauge CRCA Steel sheet |
| Construction | Upper bed support rail sections (tolerance ยฑ 2 mm excluding wall thickness) | Tube of size 50 mm X 25 mm with 1.2 mm wall thickness, Tube of size 50 mm X 25 mm with 0.6 mm wall thickness(for SS), Tube of size 50.8 mm X 25.4 mm with 2 mm wall thickness |
| Construction | Head board sections (tolerance ยฑ 2 mm excluding wall thickness) | Tube of size 50 mm X 25 mm and 25 mm X 25 mm with 1.2 mm wall thickness, Tube of size 50 mm X 25 mm and 25 mm X 25 mm with 0.6 mm wall thickness(for SS), NA |
| Construction | Tail board sections (tolerance ยฑ 2 mm excluding wall thickness) | Tube of size 50 mm X 25 mm and 25 mm X 25 mm with 1.2 mm wall thickness, Tube of size 50 mm X 25 mm and 25 mm X 25 mm with 0.6 mm wall thickness(for SS), NA |
| Colour & Finish | Paint /Finish of Metal parts | Powder Coating |
| Colour & Finish | Finish of head board / Tail board | Powder Coating |
| Colour & Finish | Min Powder/paint coating thickness (Micron) | 50 microns, 60 microns, NA |
| Colour & Finish | Colour of bed (Metal Frame) | Black, As per Buyer Choice |
| Certification & Warranty | Warranty period | 1, 2, 3, 4, 5 Or higher |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
Additional Doc 1 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Jammu And Kashmir State Sports Council
Directorate Of Technical Education
๐ VELLORE, TAMIL NADU
Engineers India Limited
๐ SURENDRA NAGAR, GUJARAT
Indian Council Of Agricultural Research (icar)
๐ DIMAPUR, NAGALAND
Indian Army
๐ INDORE, MADHYA PRADESH
Sign up now to access all documents
Main Document
CATALOG Specification
GEM_GENERAL_TERMS_AND_CONDITIONS