TenderDekho Logo
GEM

Government Tender Published for SPECTROPHOTOMETER in JAMMU, JAMMU & KASHMIR

Bid Publish Date

11-Jun-2026, 3:37 pm

Bid End Date

22-Jun-2026, 4:00 pm

EMD

₹28,000

Progress

Issue11-Jun-2026, 3:37 pm
AwardPending
Explore all 4 tabs to view complete tender details

Quantity

2

Bid Type

Two Packet Bid

Categories 18

A tender has been published for Sher-e-kashmir University Of Agricultural Sciences And Technology Of Jammu SPECTROPHOTOMETER (Q2) in JAMMU, JAMMU & KASHMIR. Quantity: 2 by. Submission Deadline: 22-06-2026 16: 00: 00. Check eligibility and apply.

Additional Tender Data

Commercial Details

Tender Category

Goods

Bid To RA

No

Bid To RA Enabled

Yes

Item Category

SPECTROPHOTOMETER (Q2)

Authority Records

HIGHER EDUCATION DEPARTMENT

BID & GeM Expert Consultancy

End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.

Bid Preparation GeM Registration Document Filing

Free consultation · 24h response

Documents 4

GeM-Bidding-9454831.pdf

Main Document

CATALOG-Specification-1

CATALOG Specification

Buyer uploaded ATC document

ATC

GEM General Terms and Conditions Document

GEM_GENERAL_TERMS_AND_CONDITIONS

Past Similar Tenders (Historical Results)

5 found

SPECTROPHOTOMETER

Rajiv Gandhi Centre For Biotechnology (rgcb)

THIRUVANANTHAPURAM, KERALA

Posted: 29 May 2025
Closed: 11 June 2025
GEM

SPECTROPHOTOMETER

Department Of Drugs Control

Posted: 11 November 2024
Closed: 21 November 2024
GEM

SPECTROPHOTOMETER

Indian Institutes Of Science Education And Research (iiser)

GANJAM, ODISHA

Posted: 9 January 2025
Closed: 30 January 2025
GEM

SPECTROPHOTOMETER

N/a

JAUNPUR, UTTAR PRADESH

Posted: 11 January 2025
Closed: 1 February 2025
GEM

SPECTROPHOTOMETER

National Institute Of Technology (nit)

BHOPAL, MADHYA PRADESH

Posted: 14 January 2025
Closed: 4 February 2025
GEM

Technical Specifications 1 Item

Item #1 Details

View Catalog
Category Specification Requirement
LIGHT SOURCE Light Source Halogen Lamp, Deuterium Lamp
LIGHT SOURCE Diffraction Grating (lines/mm) 1200
LIGHT SOURCE Switching of Light Source Automatic
LIGHT SOURCE Wavelength Setting And Scanning Automatic
TYPE Type of Spectrophotometer UV - VISIBLE
TYPE Type of Optical System Double Beam
TYPE Monochromator Type Czerny-turner
TYPE Detector Type Photodiode
TYPE Spectral Bandwidth Type Fixed Bandwidth
OPTICAL PERFORMANCE Source Wavelength - Minimum 190.0
OPTICAL PERFORMANCE Source Wavelength - Maximum 1100, 1500, 2000, 2500, 2700, 3000, 3200, 3300, 1650 Or higher
OPTICAL PERFORMANCE Resolution 1.0
OPTICAL PERFORMANCE Wavelength Accuracy (+/-) 0.1
OPTICAL PERFORMANCE Bandwidth (nm) 1
OPTICAL PERFORMANCE Focal length (mm) 0 to 49
OPTICAL PERFORMANCE Photometric measurement modes Transmittance, Absorbance, Concentration (Wavelength, time), Reflectance, Energy
OPTICAL PERFORMANCE Photometric Absorbance (Max) (Abs) (+/-) 4
OPTICAL PERFORMANCE Photometric Absorbance Accuracy (Max) (+/-) 0.001 - 0.002 Or lower
OPTICAL PERFORMANCE Photometric Transmittance (Max) (+/-) 100.0
OPTICAL PERFORMANCE Photometric Transmittance Accuracy (Max) (+/-) 0.0 - 0.5 Or lower
OPTICAL PERFORMANCE Photometric Reflectance (Max) (+/-) 100.0
GENERIC Display In-built display
GENERIC Display type LCD touchscreen
GENERIC Display Size 6.0 - 30.0 Or higher
GENERIC Test result printing Through external printer
GENERIC If inbuilt printer, Type of printer N/A
GENERIC Internal storage(GB) 32.0 - 80.0 Or higher
GENERIC Mximum Path Length of sample 100.0
GENERIC Number of Cuvettes supplied-inclusive in the scope of supply 2
GENERIC Spares and Consumables inclusive in the scope of supply Yes
OPERATING CONDITIONS Minimum Operating Temperature 10.0
OPERATING CONDITIONS Maximum Operating Temperature 35.0
OPERATING CONDITIONS Operating Humidity (RH) (%) at 40 degree C 80.0
WARRANTY Onsite Warranty 1.0
WARRANTY Availability of Spares (at extra cost) 7.0
Certification Availability of UL/CE Certification as per EN 61010-1:2010 Safety requirements for electrical equipment for measurement, control, and laboratory use General requirements Yes
Certification Conformance to EMC/EMI as per EN 61326-1:2013 Electrical equipment for measurement, control and laboratory use Yes
Certification Availability of Test Reports from Central Govt / NABL approved / ILAC acredited lab to prove conformity to the specification No

🤖 AI-Powered Bidder Prediction

Discover companies most likely to bid on this tender

Live AI
Historical Data

Required Documents

1

Experience Criteria

2

Past Performance

3

Bidder Turnover

4

Certificate (Requested in ATC)

5

OEM Authorization Certificate

6

OEM Annual Turnover

7

Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria

8

the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer

Similar Tenders

5 found

Directorate Of Medical Education Madhya Pradesh Spectrophotometer Tender Satna 2026 - IS 61010-1/EN 61326-1 Compliant

Directorate Of Medical Education Government Of Madhya Pradesh

📍 Satna, MADHYA PRADESH

⏰ Deadline: 3 weeks left
🛒 Type: Goods
View GEM

SPECTROPHOTOMETER

State Forensic Science Laboratory Chhattisgarh

📍 RAIPUR, CHHATTISGARH

EMD: ₹40,000
⏰ Deadline: 3 weeks left
🛒 Type: Goods
View GEM
Urgent

Delhi University Spectrophotometer Tender West Delhi 110008 - IS 61010-1 Safety Certification 2026

Delhi University

📍 SOUTH WEST DELHI, DELHI

⏰ Deadline: 4 days left
🛒 Type: Goods
View GEM
Urgent

Atomic Absorption Spectrophotometer (AAS)

Sher-e-kashmir University Of Agricultural Sciences And Technology Of Jammu

📍 JAMMU, JAMMU & KASHMIR

EMD: ₹1.5 L
⏰ Deadline: 6 days left
🛒 Type: Goods
View GEM

Indian Institute Of Packaging Benchtop Spectrophotometer Tender 2026 India ISO/IS standards & 25% quantity option

Indian Institute Of Packaging

📍 EAST DELHI, DELHI

⏰ Deadline: 3 weeks left
🛒 Type: Goods
View GEM