Ventilation Management Training Simulator
Jawaharlal Institute Of Postgraduate Medical Education And Research (jipmer)
Progress
Quantity
8
Bid Type
Single Packet Bid
North Western Railway invites bids for Ventilation Management Training Simulator (Q3) in Ajmer, RAJASTHAN. Quantity: 8. Submission Deadline: 04-08-2026 15: 00: 00. Submit your proposal before the deadline.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
Ventilation Management Training Simulator (Q3)
Max Delivery Days
45
Delivery Locations
1
Delivery Cities
Ajmer
Delivery Pincodes
305001
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| Prem Ranjan Thakur | 305001,CMS, Railway Hospital, Beawer Road , Ajmer | Ajmer | Rajasthan | 305001 | 8 | 45 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
GEM_GENERAL_TERMS_AND_CONDITIONS
Jawaharlal Institute Of Postgraduate Medical Education And Research (jipmer)
Indian Army
BARMER, RAJASTHAN
Indian Navy
ERNAKULAM, KERALA
All India Institute Of Medical Sciences (aiims)
Indian Army
LUDHIANA, PUNJAB
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| GENERIC | Product Description | Ventilation Management Training Simulator |
| GENERIC | Purpose | Simulator intended for ventilation management training in respiratory care, critical care, pulmonology, anesthesia, and emergency medicine |
| GENERIC | Application | Airway |
| GENERIC | Patient simulator Type | Adult |
| GENERIC | Material of the Simulator (Hazardous free) | Silicone |
| GENERIC | Patient Simulator Color | Skin Color |
| GENERIC | Patient Simulator Texture | Close to the Human Skin |
| GENERIC | Patient simulator shall be close to human physiology, anatomically accurate and realistically sculpted | Yes |
| GENERIC | Patient Simulator design | Wireless |
| GENERIC | Simulated Ventilator included with Patient Simulator | No |
| GENERIC | Additional Requirement | NA |
| Patient Simulator Features | Patient simulator to facilitate ventilation simulation for critically ill patient | Yes |
| Patient Simulator Features | Weight of Patient Simulator (in Kgs) | Suitable for Adult |
| Patient Simulator Features | Height of Patient Simulator (in cms) | Suitable for Adult |
| Patient Simulator Features | No Noise interference with unwanted patient simulator body movement | Yes |
| Patient Simulator Features | Types of Simulation input for Simulator | Lab Values |
| Patient Simulator Features | Unilateral Function of Simulator | Chest Movement |
| Patient Simulator Features | Airway Features Display on Graphical User Interface (GUI) | Bag Valve Mask Ventilation and Intubation, Indicator for rise and fall of simulator chest |
| Patient Simulator Features | ET Tube Insertion | Yes |
| Patient Simulator Features | LMA Insertion | Yes |
| Patient Simulator Features | Variable Lung Resistance | Yes |
| Patient Simulator Features | Bilateral and unilateral chest rise and fall | Yes |
| Patient Simulator Features | CO2 exhalation | Yes |
| Patient Simulator Features | Normal and abnormal breath sounds | Yes |
| Patient Simulator Features | Multiple Airway skills | Controllable open/closed airway, Nasotracheal intubation, Orotracheal intubation, Positive-Pressure Ventilation |
| Patient Simulator Features | Automatic Airway Devices Recognition System | NA |
| Patient Simulator Features | Breathing Features | Bilateral and unilateral chest rise and fall, Simulated spontaneous breathing |
| Patient Simulator Features | Breathing Complications (features) | Facility for Unilateral & Bilateral chest movement |
| Patient Simulator Features | Adjusted Resistance | Yes |
| Patient Simulator Features | Adjusted Compliance | Yes |
| Patient Simulator Features | Easy to use pre-programmed patient cases | Normal |
| Patient Simulator Features | Modes of Ventilation | All advance ventilation mode |
| Patient Simulator Features | Software included (license & support) | NA |
| Patient Simulator Features | Additional Requirement 1 | NA |
| Simulated Ventilator Specifications | Ventilator shall mimic a wide range of respiratory conditions and standard settings found on conventional hospital ventilators currently available in market | NA |
| Simulated Ventilator Specifications | Software included (License & Support) | NA |
| Simulated Ventilator Specifications | Capable to allow instructors to implement multiple ventilation therapy scenarios suited for in-hospital environments | NA |
| Simulated Ventilator Specifications | Offers full range of Patient monitored values (Respiratory parameters) | NA |
| Simulated Ventilator Specifications | Facilty for operator adjustable parameter for each mode of ventilation common to conventional hospital ventilators issue | NA |
| Simulated Ventilator Specifications | Provides experimental learning skills required to manage and monitor ventilation of a patient and troubleshoot ventilator issues | NA |
| Simulated Ventilator Specifications | Ventilation Loops | NA |
| Simulated Ventilator Specifications | Waveforms | NA |
| Simulated Ventilator Specifications | Inspiratory hold and Expiratory hold feature available | NA |
| Simulated Ventilator Specifications | Additional features available | NA |
| Simulated Ventilator Specifications | Provides detailed metrics (records) after completing the simulation session | NA |
| Simulated Ventilator Specifications | Ventilation modes | NA |
| Simulated Ventilator Specifications | Accessories provided with Simulated Ventilator | Ventilator Cart, NA |
| Simulated Ventilator Specifications | Additional Requirement 2 | NA |
| System Features for Patient Simulator | Wireless tablet controls simulator remotely | No |
| System Features for Patient Simulator | Computer controls simulator remotely | No |
| System Features for Patient Simulator | Control simulations from anywhere on the available network | No |
| System Features for Patient Simulator | Facility for multiple interfaces could control/observe a single simulation | No |
| System Features for Patient Simulator | Software interface with flexible operating modes | NA |
| System Features for Patient Simulator | Modes of Simulation controls | NA |
| System Features for Patient Simulator | Salient / Additional Features | Future prediction & patient outcome display |
| System Features for Patient Simulator | Additional Requirement 3 | NA |
| Real Time Medical Devices Compatible with Simulator | Simulator compatible with Real time Medical Device | Ventilator |
| Accessories | Accessories provided | Resuscitation bag, O2 delivery devices, Breathing circuit with mask, Tracheal tube |
| PACKING | Packing | Each/Single model should be packed individually with all accessories in one easy to carry bag/box |
| CERTIFICATION | Availability of conformity certificate/test report of the equipment from OEM to prove conformity to the declared specifications | Yes |
| CERTIFICATION | Product certifications | US-FDA, EU CE (from notified body), BIS |
| CERTIFICATION | Manufacturer certifications | ISO: 13485 (Latest), ISO 9001 (Latest) |
| CERTIFICATION | Electrical Safety Standards | IEC/EN 60601-1 |
| CERTIFICATION | Submission of all necessary regulatory certifications, test reports and Electrical Safety certificate to the buyer as and when demanded | Yes |
| CERTIFICATION | Additional Requirement 4 | NA |
| DEMONSTRATION & TRAINING | Scope of supply includes demonstration to the user while delivering the product | Yes |
| DEMONSTRATION & TRAINING | Complete hands on training about all the features and Basic Manintenance to be provided by seller to the buyer | Yes |
| DEMONSTRATION & TRAINING | User/Technical/Maintenance manuals to be supplied in English in hard and soft copy | Yes |
| WARRANTY | Warranty in Years excluding Consumables (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) | 5 Or higher |
Discover companies most likely to bid on this tender
Past Performance
Certificate (Requested in ATC)
OEM Authorization Certificate *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Admission Committee For Professional Medical Educational Courses B. J. Medical College Ahmedabad
📍 AHMEDABAD, GUJARAT
Directorate Of Medical Education And Training
Eastern Railway
📍 KOLKATA, WEST BENGAL
Eastern Railway
📍 KOLKATA, WEST BENGAL
South Western Railway
Sign up now to access all documents
Main Document
CATALOG Specification
GEM_GENERAL_TERMS_AND_CONDITIONS