0.8 Tr 4 Compact cassette,9.5mm dia with tube thickness 1.2 mm with 19 mm thick insulation,6.4 mm d
All India Radio
CENTRAL DELHI, DELHI
Progress
Quantity
1948
Category
14 HP Outdoor Unit
Bid Type
Two Packet Bid
Public procurement opportunity for Bureau Of Civil Aviation Security (bcas) 14 HP Outdoor Unit, 1. 3 TR, 1. 5 TR, 2. 0 TR, 3. 0 TR, 3. 5 TR, Indoor Outdoor Y Joints, Remote Controllers, 6. 4 mm dia with tube thickness 0. 8 mm with 13 mm thick insulation, 9. 5 mm dia with tube thickness 0. 8 mm with 13 mm thick insulation, 12. 7 mm dia with tube thickness 0. 8 mm with 13 mm thick insulation, 15. 86 mm dia with tube thickness 1. 0 mm with 19 mm thick insulation, 19. 1 mm dia with tube thickness 1. 0 mm with 19 mm thick insulation, 22. 2 mm dia with tube thickness 1. 0 mm with 19 mm thick insulation, 25. 4 mm dia with tube thickness 1. 0 mm with 19 mm thick insulation, 28. 58 mm dia with tube thickness 1. 0 mm with 19 mm thick insulation, 34. 9 mm dia with tube thickness 1. 0 mm with 19 mm thick insulation, 3 Core X 2. 5 Sq. mm For Power Supply of all VRF indoor units and SCAC Outdoor units, 2 Core X 1. 5 Sq. mm Shielded For communication of VRF System, 4 Core X 10 Sq. mm, 20 mm, 150 mm width x 50 mm depth x 1. 6 mm thickness, 300 mm width x 50 mm depth x 1. 6 mm thickness, Supply of 32 mm Dia, Supply of 40 mm Dia, 3 inch X 3 inch C channel in SOUTH GOA, GOA. Quantity: 1948 issued by. Submission Deadline: 30-06-2026 17: 00: 00. View full details and respond.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
14 HP Outdoor Unit , 1.3 TR , 1.5 TR , 2.0 TR , 3.0 TR , 3.5 TR , Indoor Outdoor Y Joints , Remote Controllers , 6.4 mm dia with tube thickness 0.8 mm with 13 mm thick insulation , 9.5 mm dia with tube thickness 0.8 mm with 13 mm thick insulation , 12.7 mm dia with tube thickness 0.8 mm with 13 mm thick insulation , 15.86 mm dia with tube thickness 1.0 mm with 19 mm thick insulation , 19.1 mm dia with tube thickness 1.0 mm with 19 mm thick insulation , 22.2 mm dia with tube thickness 1.0 mm with 19 mm thick insulation , 25.4 mm dia with tube thickness 1.0 mm with 19 mm thick insulation , 28.58 mm dia with tube thickness 1.0 mm with 19 mm thick insulation , 34.9 mm dia with tube thickness 1.0 mm with 19 mm thick insulation , 3 Core X 2.5 Sq.mm For Power Supply of all VRF indoor units and SCAC Outdoor units , 2 Core X 1.5 Sq. mm Shielded For communication of VRF System , 4 Core X 10 Sq. mm , 20 mm , 150 mm width x 50 mm depth x 1.6 mm thickness , 300 mm width x 50 mm depth x 1.6 mm thickness , Supply of 32 mm Dia , Supply of 40 mm Dia , 3 inch X 3 inch C channel
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
BOQ
BOQ
GEM_GENERAL_TERMS_AND_CONDITIONS
All India Radio
CENTRAL DELHI, DELHI
National Institute Of Fashion Technology (nift) Head Office New Delhi
HYDERABAD, TELANGANA
Hindustan Petroleum Corporation Ltd
HYDERABAD, TELANGANA
Canara Bank
MADURAI, TAMIL NADU
Central University Of Jammu
Samba, JAMMU & KASHMIR
Tender Results
Loading results...
14 HP Outdoor Unit
Supply of modular type Variable Refrigerant Flow aircooled Outdoor units suitable for cooling and heating, having 100 percentage hermetically sealed inverter type Scroll Compressor
1.3 TR
Supply of following minimum capacity 4-way flow VRF Cassette Type Indoor ceiling mounted unit
1.5 TR
Supply of following minimum capacity 4-way flow VRF Cassette Type Indoor ceiling mounted unit
2.0 TR
Supply of following minimum capacity 4-way flow VRF Cassette Type Indoor ceiling mounted unit
3.0 TR
Supply of following minimum capacity 4-way flow VRF Cassette Type Indoor ceiling mounted unit
3.5 TR
Supply of following minimum capacity 4-way flow VRF Cassette Type Indoor ceiling mounted unit
Indoor Outdoor Y Joints
Supply of Yor T or Refnet or Multi Joints. Joints shall be manufactured and supplied by same OEM make as of ODUs and IDUs
Remote Controllers
Supply of wireless remote controller with IR receivers for VRF individual indoor units.
6.4 mm dia with tube thickness 0.8 mm with 13 mm thick insulation
Supply of following nominal sizes of soft or hard drawn copper refrigerant piping for VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing or brazing including accessories, insulated with XPLE Class-O tubular insulation with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications
9.5 mm dia with tube thickness 0.8 mm with 13 mm thick insulation
Supply of following nominal sizes of soft or hard drawn copper refrigerant piping for VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing or brazing including accessories, insulated with XPLE Class-O tubular insulation with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications
12.7 mm dia with tube thickness 0.8 mm with 13 mm thick insulation
Supply of following nominal sizes of soft or hard drawn copper refrigerant piping for VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing or brazing including accessories, insulated with XPLE Class-O tubular insulation with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications
15.86 mm dia with tube thickness 1.0 mm with 19 mm thick insulation
Supply of following nominal sizes of soft or hard drawn copper refrigerant piping for VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing or brazing including accessories, insulated with XPLE Class-O tubular insulation with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications
19.1 mm dia with tube thickness 1.0 mm with 19 mm thick insulation
Supply of following nominal sizes of soft or hard drawn copper refrigerant piping for VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing or brazing including accessories, insulated with XPLE Class-O tubular insulation with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications
22.2 mm dia with tube thickness 1.0 mm with 19 mm thick insulation
Supply of following nominal sizes of soft or hard drawn copper refrigerant piping for VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing or brazing including accessories, insulated with XPLE Class-O tubular insulation with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications
25.4 mm dia with tube thickness 1.0 mm with 19 mm thick insulation
Supply of following nominal sizes of soft or hard drawn copper refrigerant piping for VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing or brazing including accessories, insulated with XPLE Class-O tubular insulation with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications
28.58 mm dia with tube thickness 1.0 mm with 19 mm thick insulation
Supply of following nominal sizes of soft or hard drawn copper refrigerant piping for VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing or brazing including accessories, insulated with XPLE Class-O tubular insulation with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications
34.9 mm dia with tube thickness 1.0 mm with 19 mm thick insulation
Supply of following nominal sizes of soft or hard drawn copper refrigerant piping for VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing or brazing including accessories, insulated with XPLE Class-O tubular insulation with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications
3 Core X 2.5 Sq.mm For Power Supply of all VRF indoor units and SCAC Outdoor units
Supply of following FRLS multi core control cables cum Transmission wiring between indoor and outdoor unit or industrial flexible cable on surface or recess i and c connection the both indoor and outdoor unit for communication complete with required clamps/ Supports, etc as reqd.
2 Core X 1.5 Sq. mm Shielded For communication of VRF System
Supply of following FRLS multi core control cables cum Transmission wiring between indoor and outdoor unit or industrial flexible cable on surface or recess i and c connection the both indoor and outdoor unit for communication complete with required clamps/ Supports, etc as reqd.
4 Core X 10 Sq. mm
Supply of 4 core armoured PVC or XLPE insulated, PVC sheathed copper conductor cable of 1.1 KV grade with ISI mark
20 mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface or recess including cutting the wall and making good the same in case of recessed conduit
150 mm width x 50 mm depth x 1.6 mm thickness
Supplying and Installing following size of perforated Hot Dipped Galvenised Iron Cable Tray withThickness not less than 50 microns with perforation not more than 17.5%, in convinient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including GI bolts & nuts, etc. complete as required.
300 mm width x 50 mm depth x 1.6 mm thickness
Supplying and Installing following size of perforated Hot Dipped Galvenised Iron Cable Tray withThickness not less than 50 microns with perforation not more than 17.5%, in convinient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including GI bolts & nuts, etc. complete as required.
Supply of 32 mm Dia
Drain piping in hard PVC with all fittings, supports and clamps including drilling hole in wall chipping wall etc to conceal and to route the drain pipe.
Supply of 40 mm Dia
Drain piping in hard PVC with all fittings, supports and clamps including drilling hole in wall chipping wall etc to conceal and to route the drain pipe.
3 inch X 3 inch C channel
Supply of MS Fabricated Outdoor units Stand made up of C Channel with proper First coat of Zinc Oxide and second coat of black colour oil based paint
14 HP Outdoor Unit
Installation, Testing and Commissioning of modular type Variable Refrigerant Flow aircooled Outdoor units suitable for cooling and heating, having 100 % hermetically sealed inverter type Scroll Compressor (s), minimum two compressors for above 14HP modules
1.3 TR
Installation, Testing and Commissioning of following minimum capacity 4-way flow VRF Cassette Type Indoor ceiling mounted unit
1.5 TR
Installation, Testing and Commissioning of following minimum capacity 4-way flow VRF Cassette Type Indoor ceiling mounted unit
2.0 TR
Installation, Testing and Commissioning of following minimum capacity 4-way flow VRF Cassette Type Indoor ceiling mounted unit
3.0 TR
Installation, Testing and Commissioning of following minimum capacity 4-way flow VRF Cassette Type Indoor ceiling mounted unit
3.5 TR
Installation, Testing and Commissioning of following minimum capacity 4-way flow VRF Cassette Type Indoor ceiling mounted unit
Indoor Outdoor Y Joints
Installation, Testing and Commissioning of Y or T or Refnet or Multi Joints with required Brazing, Clamps & Supports.
Remote Controllers
Installation, Testing and Commissioning of wireless remote controller with IR receivers for VRF individual indoor units.
6.4 mm dia with tube thickness 0.8 mm with 13 mm thick insulation
Installation, testing and comissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft or hard drawn copper refrigerant piping for VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing or brazing including accessories, insulated with XPLE Class-O tubular insulation with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications
9.5 mm dia with tube thickness 0.8 mm with 13 mm thick insulation
Installation, testing and comissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft or hard drawn copper refrigerant piping for VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing or brazing including accessories, insulated with XPLE Class-O tubular insulation with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications
12.7 mm dia with tube thickness 0.8 mm with 13 mm thick insulation
Installation, testing and comissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft or hard drawn copper refrigerant piping for VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing or brazing including accessories, insulated with XPLE Class-O tubular insulation with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications
15.86 mm dia with tube thickness 1.0 mm with 19 mm thick insulation
Installation, testing and comissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft or hard drawn copper refrigerant piping for VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing or brazing including accessories, insulated with XPLE Class-O tubular insulation with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications
19.1 mm dia with tube thickness 1.0 mm with 19 mm thick insulation
Installation, testing and comissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft or hard drawn copper refrigerant piping for VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing or brazing including accessories, insulated with XPLE Class-O tubular insulation with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications
22.2 mm dia with tube thickness 1.0 mm with 19 mm thick insulation
Installation, testing and comissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft or hard drawn copper refrigerant piping for VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing or brazing including accessories, insulated with XPLE Class-O tubular insulation with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications
25.4 mm dia with tube thickness 1.0 mm with 19 mm thick insulation
Installation, testing and comissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft or hard drawn copper refrigerant piping for VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing or brazing including accessories, insulated with XPLE Class-O tubular insulation with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications
28.58 mm dia with tube thickness 1.0 mm with 19 mm thick insulation
Installation, testing and comissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft or hard drawn copper refrigerant piping for VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing or brazing including accessories, insulated with XPLE Class-O tubular insulation with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications
34.9 mm dia with tube thickness 1.0 mm with 19 mm thick insulation
Installation, testing and comissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft or hard drawn copper refrigerant piping for VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing or brazing including accessories, insulated with XPLE Class-O tubular insulation with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications
3 Core X 2.5 Sq.mm For Power Supply of all VRF indoor units and SCAC Outdoor units
Installation, Testing and Commissioning of following FRLS multi core control cables cum Transmission wiring between indoor and outdoor unit or industrial flexible cable on surface or recess i and c connection the both indoor and outdoor unit for communication complete with required clamps or Supports
2 Core X 1.5 Sq. mm Shielded For communication of VRF System
Installation, Testing and Commissioning of following FRLS multi core control cables cum Transmission wiring between indoor and outdoor unit or industrial flexible cable on surface or recess i and c connection the both indoor and outdoor unit for communication complete with required clamps or Supports
4 Core X 10 Sq. mm
Installation, Testing and Commissioning of following FRLS multi core control cables cum Transmission wiring between indoor and outdoor unit or industrial flexible cable on surface or recess i and c connection the both indoor and outdoor unit for communication complete with required clamps or Supports
20 mm
Installation, fixing and commissioning of following sizes of medium class PVC conduit along with accessories in surface or recess including cutting the wall and making good the same in case of recessed conduit as required.
150 mm width x 50 mm depth x 1.6 mm thickness
Installing and Fixing following size of perforated Galvenised Iron Cable Tray with Thickness not less than 50 microns with perforation not more than 17.5 percent, in convinient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including GI bolts & nuts, etc. complete as required.
300 mm width x 50 mm depth x 1.6 mm thickness
Installing and Fixing following size of perforated Galvenised Iron Cable Tray with Thickness not less than 50 microns with perforation not more than 17.5 percent, in convinient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including GI bolts & nuts, etc. complete as required.
Supply of 32 mm Dia
Installation and Testing of Drain piping in hard PVC with all fittings, supports and clamps including drilling hole in wall chipping wall etc to conceal and to route the drain pipe.
Supply of 40 mm Dia
Installation and Testing of Drain piping in hard PVC with all fittings, supports and clamps including drilling hole in wall chipping wall etc to conceal and to route the drain pipe.
3 inch X 3 inch C channel
Installation of MS Fabricated Outdoor units Stand made up of C Channel with proper First coat of Zinc Oxide and second coat of black colour oil based paint
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) | Price Trends |
|---|---|---|---|---|---|---|---|
| 1 | 14 HP Outdoor Unit | Supply of modular type Variable Refrigerant Flow aircooled Outdoor units suitable for cooling and heating, having 100 percentage hermetically sealed inverter type Scroll Compressor | 2 | numbers | bcasro_goa | 20 | |
| 2 | 1.3 TR | Supply of following minimum capacity 4-way flow VRF Cassette Type Indoor ceiling mounted unit | 2 | numbers | bcasro_goa | 20 | |
| 3 | 1.5 TR | Supply of following minimum capacity 4-way flow VRF Cassette Type Indoor ceiling mounted unit | 2 | numbers | bcasro_goa | 20 | |
| 4 | 2.0 TR | Supply of following minimum capacity 4-way flow VRF Cassette Type Indoor ceiling mounted unit | 1 | numbers | bcasro_goa | 20 | |
| 5 | 3.0 TR | Supply of following minimum capacity 4-way flow VRF Cassette Type Indoor ceiling mounted unit | 4 | numbers | bcasro_goa | 20 | |
| 6 | 3.5 TR | Supply of following minimum capacity 4-way flow VRF Cassette Type Indoor ceiling mounted unit | 1 | numbers | bcasro_goa | 20 | |
| 7 | Indoor Outdoor Y Joints | Supply of Yor T or Refnet or Multi Joints. Joints shall be manufactured and supplied by same OEM make as of ODUs and IDUs | 10 | numbers | bcasro_goa | 20 | |
| 8 | Remote Controllers | Supply of wireless remote controller with IR receivers for VRF individual indoor units. | 10 | numbers | bcasro_goa | 20 | |
| 9 | 6.4 mm dia with tube thickness 0.8 mm with 13 mm thick insulation | Supply of following nominal sizes of soft or hard drawn copper refrigerant piping for VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing or brazing including accessories, insulated with XPLE Class-O tubular insulation with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications | 24 | meter | bcasro_goa | 20 | |
| 10 | 9.5 mm dia with tube thickness 0.8 mm with 13 mm thick insulation | Supply of following nominal sizes of soft or hard drawn copper refrigerant piping for VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing or brazing including accessories, insulated with XPLE Class-O tubular insulation with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications | 106 | meter | bcasro_goa | 20 | |
| 11 | 12.7 mm dia with tube thickness 0.8 mm with 13 mm thick insulation | Supply of following nominal sizes of soft or hard drawn copper refrigerant piping for VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing or brazing including accessories, insulated with XPLE Class-O tubular insulation with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications | 24 | meter | bcasro_goa | 20 | |
| 12 | 15.86 mm dia with tube thickness 1.0 mm with 19 mm thick insulation | Supply of following nominal sizes of soft or hard drawn copper refrigerant piping for VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing or brazing including accessories, insulated with XPLE Class-O tubular insulation with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications | 72 | meter | bcasro_goa | 20 | |
| 13 | 19.1 mm dia with tube thickness 1.0 mm with 19 mm thick insulation | Supply of following nominal sizes of soft or hard drawn copper refrigerant piping for VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing or brazing including accessories, insulated with XPLE Class-O tubular insulation with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications | 15 | meter | bcasro_goa | 20 | |
| 14 | 22.2 mm dia with tube thickness 1.0 mm with 19 mm thick insulation | Supply of following nominal sizes of soft or hard drawn copper refrigerant piping for VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing or brazing including accessories, insulated with XPLE Class-O tubular insulation with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications | 15 | meter | bcasro_goa | 20 | |
| 15 | 25.4 mm dia with tube thickness 1.0 mm with 19 mm thick insulation | Supply of following nominal sizes of soft or hard drawn copper refrigerant piping for VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing or brazing including accessories, insulated with XPLE Class-O tubular insulation with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications | 12 | meter | bcasro_goa | 20 | |
| 16 | 28.58 mm dia with tube thickness 1.0 mm with 19 mm thick insulation | Supply of following nominal sizes of soft or hard drawn copper refrigerant piping for VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing or brazing including accessories, insulated with XPLE Class-O tubular insulation with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications | 21 | meter | bcasro_goa | 20 | |
| 17 | 34.9 mm dia with tube thickness 1.0 mm with 19 mm thick insulation | Supply of following nominal sizes of soft or hard drawn copper refrigerant piping for VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing or brazing including accessories, insulated with XPLE Class-O tubular insulation with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications | 37 | meter | bcasro_goa | 20 | |
| 18 | 3 Core X 2.5 Sq.mm For Power Supply of all VRF indoor units and SCAC Outdoor units | Supply of following FRLS multi core control cables cum Transmission wiring between indoor and outdoor unit or industrial flexible cable on surface or recess i and c connection the both indoor and outdoor unit for communication complete with required clamps/ Supports, etc as reqd. | 18 | meter | bcasro_goa | 20 | |
| 19 | 2 Core X 1.5 Sq. mm Shielded For communication of VRF System | Supply of following FRLS multi core control cables cum Transmission wiring between indoor and outdoor unit or industrial flexible cable on surface or recess i and c connection the both indoor and outdoor unit for communication complete with required clamps/ Supports, etc as reqd. | 210 | meter | bcasro_goa | 20 | |
| 20 | 4 Core X 10 Sq. mm | Supply of 4 core armoured PVC or XLPE insulated, PVC sheathed copper conductor cable of 1.1 KV grade with ISI mark | 40 | meter | bcasro_goa | 20 | |
| 21 | 20 mm | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface or recess including cutting the wall and making good the same in case of recessed conduit | 180 | meter | bcasro_goa | 20 | |
| 22 | 150 mm width x 50 mm depth x 1.6 mm thickness | Supplying and Installing following size of perforated Hot Dipped Galvenised Iron Cable Tray withThickness not less than 50 microns with perforation not more than 17.5%, in convinient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including GI bolts & nuts, etc. complete as required. | 36 | meter | bcasro_goa | 20 | |
| 23 | 300 mm width x 50 mm depth x 1.6 mm thickness | Supplying and Installing following size of perforated Hot Dipped Galvenised Iron Cable Tray withThickness not less than 50 microns with perforation not more than 17.5%, in convinient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including GI bolts & nuts, etc. complete as required. | 24 | meter | bcasro_goa | 20 | |
| 24 | Supply of 32 mm Dia | Drain piping in hard PVC with all fittings, supports and clamps including drilling hole in wall chipping wall etc to conceal and to route the drain pipe. | 60 | meter | bcasro_goa | 20 | |
| 25 | Supply of 40 mm Dia | Drain piping in hard PVC with all fittings, supports and clamps including drilling hole in wall chipping wall etc to conceal and to route the drain pipe. | 46 | meter | bcasro_goa | 20 | |
| 26 | 3 inch X 3 inch C channel | Supply of MS Fabricated Outdoor units Stand made up of C Channel with proper First coat of Zinc Oxide and second coat of black colour oil based paint | 2 | numbers | bcasro_goa | 20 | |
| 27 | 14 HP Outdoor Unit | Installation, Testing and Commissioning of modular type Variable Refrigerant Flow aircooled Outdoor units suitable for cooling and heating, having 100 % hermetically sealed inverter type Scroll Compressor (s), minimum two compressors for above 14HP modules | 2 | numbers | bcasro_goa | 20 | |
| 28 | 1.3 TR | Installation, Testing and Commissioning of following minimum capacity 4-way flow VRF Cassette Type Indoor ceiling mounted unit | 2 | numbers | bcasro_goa | 20 | |
| 29 | 1.5 TR | Installation, Testing and Commissioning of following minimum capacity 4-way flow VRF Cassette Type Indoor ceiling mounted unit | 2 | numbers | bcasro_goa | 20 | |
| 30 | 2.0 TR | Installation, Testing and Commissioning of following minimum capacity 4-way flow VRF Cassette Type Indoor ceiling mounted unit | 1 | numbers | bcasro_goa | 20 | |
| 31 | 3.0 TR | Installation, Testing and Commissioning of following minimum capacity 4-way flow VRF Cassette Type Indoor ceiling mounted unit | 4 | numbers | bcasro_goa | 20 | |
| 32 | 3.5 TR | Installation, Testing and Commissioning of following minimum capacity 4-way flow VRF Cassette Type Indoor ceiling mounted unit | 1 | numbers | bcasro_goa | 20 | |
| 33 | Indoor Outdoor Y Joints | Installation, Testing and Commissioning of Y or T or Refnet or Multi Joints with required Brazing, Clamps & Supports. | 10 | numbers | bcasro_goa | 20 | |
| 34 | Remote Controllers | Installation, Testing and Commissioning of wireless remote controller with IR receivers for VRF individual indoor units. | 10 | numbers | bcasro_goa | 20 | |
| 35 | 6.4 mm dia with tube thickness 0.8 mm with 13 mm thick insulation | Installation, testing and comissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft or hard drawn copper refrigerant piping for VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing or brazing including accessories, insulated with XPLE Class-O tubular insulation with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications | 24 | meter | bcasro_goa | 20 | |
| 36 | 9.5 mm dia with tube thickness 0.8 mm with 13 mm thick insulation | Installation, testing and comissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft or hard drawn copper refrigerant piping for VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing or brazing including accessories, insulated with XPLE Class-O tubular insulation with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications | 106 | meter | bcasro_goa | 20 | |
| 37 | 12.7 mm dia with tube thickness 0.8 mm with 13 mm thick insulation | Installation, testing and comissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft or hard drawn copper refrigerant piping for VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing or brazing including accessories, insulated with XPLE Class-O tubular insulation with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications | 24 | meter | bcasro_goa | 20 | |
| 38 | 15.86 mm dia with tube thickness 1.0 mm with 19 mm thick insulation | Installation, testing and comissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft or hard drawn copper refrigerant piping for VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing or brazing including accessories, insulated with XPLE Class-O tubular insulation with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications | 72 | meter | bcasro_goa | 20 | |
| 39 | 19.1 mm dia with tube thickness 1.0 mm with 19 mm thick insulation | Installation, testing and comissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft or hard drawn copper refrigerant piping for VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing or brazing including accessories, insulated with XPLE Class-O tubular insulation with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications | 15 | meter | bcasro_goa | 20 | |
| 40 | 22.2 mm dia with tube thickness 1.0 mm with 19 mm thick insulation | Installation, testing and comissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft or hard drawn copper refrigerant piping for VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing or brazing including accessories, insulated with XPLE Class-O tubular insulation with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications | 15 | meter | bcasro_goa | 20 | |
| 41 | 25.4 mm dia with tube thickness 1.0 mm with 19 mm thick insulation | Installation, testing and comissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft or hard drawn copper refrigerant piping for VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing or brazing including accessories, insulated with XPLE Class-O tubular insulation with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications | 12 | meter | bcasro_goa | 20 | |
| 42 | 28.58 mm dia with tube thickness 1.0 mm with 19 mm thick insulation | Installation, testing and comissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft or hard drawn copper refrigerant piping for VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing or brazing including accessories, insulated with XPLE Class-O tubular insulation with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications | 21 | meter | bcasro_goa | 20 | |
| 43 | 34.9 mm dia with tube thickness 1.0 mm with 19 mm thick insulation | Installation, testing and comissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft or hard drawn copper refrigerant piping for VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing or brazing including accessories, insulated with XPLE Class-O tubular insulation with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications | 37 | meter | bcasro_goa | 20 | |
| 44 | 3 Core X 2.5 Sq.mm For Power Supply of all VRF indoor units and SCAC Outdoor units | Installation, Testing and Commissioning of following FRLS multi core control cables cum Transmission wiring between indoor and outdoor unit or industrial flexible cable on surface or recess i and c connection the both indoor and outdoor unit for communication complete with required clamps or Supports | 18 | meter | bcasro_goa | 20 | |
| 45 | 2 Core X 1.5 Sq. mm Shielded For communication of VRF System | Installation, Testing and Commissioning of following FRLS multi core control cables cum Transmission wiring between indoor and outdoor unit or industrial flexible cable on surface or recess i and c connection the both indoor and outdoor unit for communication complete with required clamps or Supports | 210 | meter | bcasro_goa | 20 | |
| 46 | 4 Core X 10 Sq. mm | Installation, Testing and Commissioning of following FRLS multi core control cables cum Transmission wiring between indoor and outdoor unit or industrial flexible cable on surface or recess i and c connection the both indoor and outdoor unit for communication complete with required clamps or Supports | 40 | meter | bcasro_goa | 20 | |
| 47 | 20 mm | Installation, fixing and commissioning of following sizes of medium class PVC conduit along with accessories in surface or recess including cutting the wall and making good the same in case of recessed conduit as required. | 180 | meter | bcasro_goa | 20 | |
| 48 | 150 mm width x 50 mm depth x 1.6 mm thickness | Installing and Fixing following size of perforated Galvenised Iron Cable Tray with Thickness not less than 50 microns with perforation not more than 17.5 percent, in convinient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including GI bolts & nuts, etc. complete as required. | 36 | meter | bcasro_goa | 20 | |
| 49 | 300 mm width x 50 mm depth x 1.6 mm thickness | Installing and Fixing following size of perforated Galvenised Iron Cable Tray with Thickness not less than 50 microns with perforation not more than 17.5 percent, in convinient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including GI bolts & nuts, etc. complete as required. | 24 | meter | bcasro_goa | 20 | |
| 50 | Supply of 32 mm Dia | Installation and Testing of Drain piping in hard PVC with all fittings, supports and clamps including drilling hole in wall chipping wall etc to conceal and to route the drain pipe. | 60 | meter | bcasro_goa | 20 | |
| 51 | Supply of 40 mm Dia | Installation and Testing of Drain piping in hard PVC with all fittings, supports and clamps including drilling hole in wall chipping wall etc to conceal and to route the drain pipe. | 46 | meter | bcasro_goa | 20 | |
| 52 | 3 inch X 3 inch C channel | Installation of MS Fabricated Outdoor units Stand made up of C Channel with proper First coat of Zinc Oxide and second coat of black colour oil based paint | 2 | numbers | bcasro_goa | 20 |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
OEM Authorization Certificate
OEM Annual Turnover *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
National Institute Of Technology (nit)
📍 LOWER SUBANSIRI, ARUNACHAL PRADESH
Uttar Pradesh Rajya Vidyut Utpadan Nigam Limited (uprvunl) Lucknow
📍 SONBHADRA, UTTAR PRADESH
Uttar Pradesh Rajya Vidyut Utpadan Nigam Limited (uprvunl) Lucknow
📍 SONBHADRA, UTTAR PRADESH
Indo Tibetan Border Police (itbp)
📍 DARJEELING, WEST BENGAL
Hindustan Aeronautics Limited (hal)
📍 BANGALORE, KARNATAKA
Sign up now to access all documents
Main Document
BOQ
BOQ
GEM_GENERAL_TERMS_AND_CONDITIONS