OTO - Acoustic Emissions (OAE) Instrument for New Born Infant and Children (V2) - RBSK
N/a
GAUTAM BUDDHA NAGAR, UTTAR PRADESH
Bid Publish Date
07-Jul-2026, 2:41 pm
Bid End Date
28-Jul-2026, 3:00 pm
Location
Progress
Quantity
1
Bid Type
Two Packet Bid
Ali Yavar Jung National Institute For The Hearing Handicapped (ayjnihh) announces a tender for OTO - Acoustic Emissions (OAE) Instrument for New Born Infant and Children (V2) - RBSK (Q3) in GAUTAM BUDDHA NAGAR, UTTAR PRADESH. Quantity: 1. Submission Deadline: 28-07-2026 15: 00: 00. Last date to apply is approaching fast!
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
OTO - Acoustic Emissions (OAE) Instrument for New Born Infant and Children (V2) - RBSK (Q3)
Max Delivery Days
30
Delivery Locations
1
Delivery Cities
Gautam Buddha Nagar
Delivery Pincodes
201301
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| Prem Chand | 201301,Plot No. 19, Block - P, Sector - 12 , Noida,UP-201301 | Gautam Buddha Nagar | Uttar Pradesh | 201301 | 1 | 30 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
GEM_CATEGORY_SPECIFICATION
GEM_GENERAL_TERMS_AND_CONDITIONS
N/a
GAUTAM BUDDHA NAGAR, UTTAR PRADESH
Directorate Of Medical Education And Training
BAHRAICH, UTTAR PRADESH
Directorate Of Medical Education & Research
N/a
PONDICHERRY, PUDUCHERRY
Commissioner Health Services
GONDIA, MAHARASHTRA
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| GENERAL FEATURES | Product description | Oto-acoustic emissions (OAE) Instrument for New Born,Infant and Children |
| GENERAL FEATURES | Patient application | Children from birth to 6 years |
| TECHNICAL SPECIFICATIONS | Handheld unit including probe cord and Cradle | Yes |
| TECHNICAL SPECIFICATIONS | Instrument should be provided with a Printer including power supply and power cable, Printable text file display of the acquired data, including frequency, signal, noise,response and testing parameters | Yes |
| TECHNICAL SPECIFICATIONS | Minimum Length of Probe cord for extension | 75.0 |
| TECHNICAL SPECIFICATIONS | DPOAE protocol should give fast and accurate results in as little as 10 seconds per ear | Yes |
| TECHNICAL SPECIFICATIONS | Tip should be Easy-to-clean | Yes |
| TECHNICAL SPECIFICATIONS | Results should have an Objective test (no patient response required) | Yes |
| TECHNICAL SPECIFICATIONS | Pass/Refer result should be provided (No interpretation required) | Yes |
| TECHNICAL SPECIFICATIONS | Instrument should operate on rechargeable battery | Yes |
| TECHNICAL SPECIFICATIONS | Instrument should have at least 50 test memory | Yes |
| TECHNICAL SPECIFICATIONS | DPOAE specifications | Intensity from 40 to 70 dB SPL |
| TECHNICAL SPECIFICATIONS | TEOAE module | Frequencies from 700 to 4000 Hz and Intensity of 83 dBSPL ± 3 |
| TECHNICAL SPECIFICATIONS | Frequencies | 500 to 6000 Hz |
| TECHNICAL SPECIFICATIONS | Number of independent stimulus channel | 4 |
| TECHNICAL SPECIFICATIONS | Number of signal input channel | 2 |
| TECHNICAL SPECIFICATIONS | Facility to edit the test protocol and save | Yes |
| TECHNICAL SPECIFICATIONS | Database management software to be provided | Yes |
| TECHNICAL SPECIFICATIONS | Software and/or standard of communication(where ever required) | In built |
| TECHNICAL SPECIFICATIONS | Weight of the instrument | < 2 kg |
| TECHNICAL SPECIFICATIONS | Instrument should be compatible with laptop, desktop for transfer and storage of test data | Yes |
| STANDARD ACCESSORIES AND CONSUMABLES | Minimum number of reusable ear-tips provided of various sizes starting from 3mm to 12 mm | 10 for each size |
| STANDARD ACCESSORIES AND CONSUMABLES | Probe cord (1 Nos) | Yes |
| STANDARD ACCESSORIES AND CONSUMABLES | Cradle (1 Nos) | Yes |
| STANDARD ACCESSORIES AND CONSUMABLES | Power cable (1 Nos) | Yes |
| STANDARD ACCESSORIES AND CONSUMABLES | Printer (1 Nos) | Yes |
| STANDARD ACCESSORIES AND CONSUMABLES | Carrying Bag (1 Nos) | Yes |
| STANDARD ACCESSORIES AND CONSUMABLES | Cleaning Kit | Yes |
| STANDARD ACCESSORIES AND CONSUMABLES | Additional Probe Knob (Nos) | 4 |
| STANDARD ACCESSORIES AND CONSUMABLES | Calibration cavity for new born, infant and children | Yes |
| ELECTRICAL REQUIREMENTS | Power Requirements | 220-240Vac; 50/60 HZ along with rechargeable inbuilt battery with two hours power backup |
| ENVIRONMEN REQUIREMENTS | Instrument should be capable of being stored continuously in ambient temperature of 0 to 50 degree C and relative humidity of 15 to 90% | Yes |
| ENVIRONMEN REQUIREMENTS | Instrument should be capable of operating continuously in ambient temperature of 10 to 40 degree C and relative humidity of 15 to 90% | Yes |
| CLEANING, DISINFECTION & STERILITY | Complete unit to be easily washable and sterilizable using both alcohol and chlorine agents | Yes |
| CERTIFICATIONS & REPORTS | Compliance to Medical Device Rules (MDR) 2017 as amended till date | Yes |
| CERTIFICATIONS & REPORTS | Availability of valid drug license for the product issued from the competent authority defined under Drugs and Cosmetic Act 1940 and Rules made there under as amended till date | Yes |
| CERTIFICATIONS & REPORTS | Manufacturing unit certification | ISO:13485 (Latest) |
| CERTIFICATIONS & REPORTS | Electrical Safety Standards | IEC/EN 60601-1 or equivalent BIS Standard |
| CERTIFICATIONS & REPORTS | Availability of Test Report for each supplied batch/product as per Medical Device Rules (MDR) 2017 as amended till date | Yes |
| CERTIFICATIONS & REPORTS | Submission of all necessary certifications, licenses and test reports to the buyer at the time of bid submission and/or along with supplies as per buyer requirement | Yes |
| TRAINING AND INSTALLATION | Supplier to perform installation, safety and operation checks before handover | Yes |
| TRAINING AND INSTALLATION | Training of users in operation and basic maintenance shall be provided | Yes |
| TRAINING AND INSTALLATION | Technical Support and required spares and consumable should be available for atleast 3 years after warranty period | Yes |
| WARRANTY AND MAINTENANCE | Warranty in Years (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) | 3, 2, 5 Or higher |
| WARRANTY AND MAINTENANCE | Contact details of manufacturer, supplier and local service agent to be provided | Yes |
| DOCUMENTATION | User, technical and maintenance manual in English detailing complete maintaining schedule should be provided | Yes |
| DOCUMENTATION | List to be provided of equipment and procedures required for local calibration and routine maintenance | Yes |
Discover companies most likely to bid on this tender
Experience Criteria
Bidder Turnover *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
N/a
📍 LUCKNOW, UTTAR PRADESH
N/a
📍 OSMANABAD, MAHARASHTRA
Ntpc Mining Limited
📍 Raigarh, CHHATTISGARH
Ntpc Limited
📍 GAUTAM BUDDHA NAGAR, UTTAR PRADESH
Employees State Insurance Corporation
Sign up now to access all documents
Main Document
GEM_CATEGORY_SPECIFICATION
GEM_GENERAL_TERMS_AND_CONDITIONS