Eastern Railway Water Tender for Fire Brigade IS 948 Q2 Conforming Equipment Munger Bihar 2025
Eastern Railway
MUNGER, BIHAR
Progress
Quantity
1
Bid Type
Single Packet Bid
Eastern Railway invites bids for Water Tender Type A for Fire Brigade Use conforming to IS 948 (Q2) in MUNGER, BIHAR. Quantity: 1. Submission Deadline: 17-07-2026 14: 00: 00. Submit your proposal before the deadline.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
Water Tender Type A for Fire Brigade Use conforming to IS 948 (Q2)
Advisory Bank
State Bank of India
ePBG Percentage
5%
ePBG Duration (Months)
15
Max Delivery Days
90
Delivery Locations
1
Delivery Cities
Munger
Delivery Pincodes
811214
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| Ray Soumitra Vijoy Bhushan | 811214,EASTERN RAILWAY LOCOMOTIVE WORKSHOP,JAMALPUR, DISTT- MUNGER | Munger | Bihar | 811214 | 1 | 90 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
GEM_CATEGORY_SPECIFICATION
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Eastern Railway
MUNGER, BIHAR
Uttar Pradesh Fire Service Govt. Of Uttar Pradesh
LUCKNOW, UTTAR PRADESH
Directorate Of Fire Service
WEST TRIPURA, TRIPURA
Directorate Of Fire Service
WEST TRIPURA, TRIPURA
Directorate Of Fire Service
WEST TRIPURA, TRIPURA
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| Functional Requirements | Water Tank Capacity (litre) | 2700.0 - 3600.0 Or higher |
| Functional Requirements | Water Tank Material | Material to be mild steel treated for anti-corrosion. Inside surface shall be prepared by sand blasting before painting. Epoxy treatment (consisting of one coat of primer and 2 coats of finish) should be given inside the water tank for corrosion resistance. |
| Functional Requirements | Requirements for Water Tank | 1. Tank shall be suitably mounted on the chassis in a manner ensuring proper load distribution on the axles; 2. The tank shall be fitted with a 75 mm bore overflow pipe; 3. A 63 mm instantaneous hydrant connection, incorporating a strainer, shall be provided for filling the tank through 50 mm bore pipe work; 4. An 100 mm bore pipeline shall be taken from the tank for the suction inlet of the pump incorporating an 100 mm quick spherical type valve. |
| Functional Requirements | Baffles & Manhole | 1. There should be minimum 2 baffles for 2700 litres water tank and 3 baffles for higher capacity; 2. The tank body and baffles shall be minimum 3 mm thick; 3. Bottom of the tank shall be minimum 4 mm thick; 4. The tank shall have a covered manhole of minimum 45 cm diameter; 5. A cleaning hole of at least 25 cm dia shall be provided at the bottom. |
| Functional Requirements | Portable Pump | 275 LPM Portable Pump Set (conforming to IS: 942) |
| Functional Requirements | Colour and Paint | Fire red colour conforming to Shade No. 536 of IS 5. The paint shall conform to IS 2932. |
| Functional Requirements | Mandatory Accessories as per clause 6*2 of IS 948 | Fire bell of 250 mm diameter, 2 nos Head lamps, 2 nos Fog lamps, Reversing light, Amber blinkers lights, Trafficators, Wind screen wipers, Tools required for normal routine maintenance, Battery operated siren, Search light, Spot light, Inspection lamp, 2 nos Tail lamps, Rear reflectors, Instrument panel, locker. |
| Chassis Parameters | Maximum Gross Vehicle Weight including crew, water and equipment | 14250.0 - 16000.0 Or higher |
| Chassis Parameters | Type of Fuel | Diesel |
| Chassis Parameters | Axle Configuration | 4 X 2 |
| Chassis Parameters | Maximum Engine Output / Power (kW) at rated RPM | 117.7 - 400.0 Or higher |
| Chassis Parameters | Vehicle Emission Compliance | BS VI |
| Chassis Parameters | Vehicle Air Intake System | Turbocharged Intercooled Or higher |
| Chassis Parameters | Type of Steering | Power Steering Or higher |
| Chassis Parameters | Performance Parameters (as per clause 2*2 of IS 948) | 1. Maximum speed on level road (fully laden) - 72 km/h; 2. Acceleration from a standing start through the gears (fully laden) - 50 km/h in 45 s; 3. The appliance shall be capable of being started from rest and move upon a gradient of 1 to 4; 4. When travelling at 48 km/h on a level dry surface the foot brake shall be capable of stopping the vehicle within a distance of 15 m from the point at which the brake is applied. The hand brake shall be capable of holding the fully laden appliance on a dry surface gradient of 1 in 4 when in neutral gear. |
| Chassis Parameters | Seating Capacity in the cabin (Including driver) | 6 |
| Chassis Parameters | Air Conditioning in Driver Cabin | No |
| Certification Parameters | Governing Specification | IS 948 |
| Certification Parameters | Certification Type | Chassis Certification along with Form 22 |
| Certification Parameters | Availability of Chassis / Original Vehicle Manufacturer's authorization in case of Body Builders | Yes |
| Warranty | Equipment and accessories are provided with applicable OEM warranty | Yes |
Discover companies most likely to bid on this tender
Certificate (Requested in ATC)
OEM Authorization Certificate *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
East Khasi Hills District Police Shillong
North Eastern Electric Power Corporation Limited
Uranium Corporation Of India Limited
📍 CUDDAPAH, ANDHRA PRADESH
Uranium Corporation Of India Limited
📍 CUDDAPAH, ANDHRA PRADESH
Bhakra Beas Management Board
Sign up now to access all documents
Main Document
GEM_CATEGORY_SPECIFICATION
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS