Bids are Invited For Gas Chromatography - Triple Quadrupole Mass Spectrometry (GC - MS - MS) in GANDHI NAGAR, GUJARAT

Bid Publish Date

08-Jan-2026, 12:48 pm

Bid End Date

29-Jan-2026, 12:00 pm

EMD

₹9,00,000

Progress

Issue08-Jan-2026, 12:48 pm
AwardPending
Explore all 4 tabs to view complete tender details

Quantity

1

Bid Type

Two Packet Bid

N/a invites bids for Gas Chromatography - Triple Quadrupole Mass Spectrometry (GC - MS - MS) (Q3) in GANDHI NAGAR, GUJARAT. Quantity: 1. Submission Deadline: 29-01-2026 12: 00: 00. Submit your proposal before the deadline.

Past Similar Tenders (Historical Results)

5 found

Customized AMC/CMC for Pre-owned Products - Liquid Chromatography -Mass Spectrometer (LC-MS) System

Indian Council Of Agricultural Research (icar)

SHIMLA, HIMACHAL PRADESH

Posted: 10 November 2025
Closed: 21 November 2025
GEM

Chhattisgarh Biotechnology Promotion Society Gas Chromatography Tender Raipur CG 2025

Chhattisgarh Biotechnology Promotion Society

RAIPUR, CHHATTISGARH

Posted: 5 November 2025
Closed: 21 November 2025
GEM

Agharkar Research Institute DST Gas Chromatography Tender Pune Maharashtra IS ISO 9001/IS IS 550 Compliant 2025

Agharkar Research Institute (ari)

PUNE, MAHARASHTRA

Posted: 29 October 2025
Closed: 8 November 2025
GEM

Liquid Chromatography (LC System) with High resolution Mass Spectrometry (HRMS) System

Indian Institute Of Technology (iit)

VARANASI, UTTAR PRADESH

Posted: 16 October 2025
Closed: 6 November 2025
GEM

High resolution– Mass spectrometry (HR-MS)

Office Of Dg (ls)

NORTH DELHI, DELHI

Posted: 16 October 2025
Closed: 6 November 2025
GEM

Technical Specifications 1 Item

Item #1 Details

View Catalog
Category Specification Requirement
GAS CHROMATOGRAPH (GC) CONFIGURATION GC Detectors inclusive in the scope of supply Flame Ionization Detector (FID)
GAS CHROMATOGRAPH (GC) CONFIGURATION "Number of FID in the System - inclusive in the scope of Supply 0
GAS CHROMATOGRAPH (GC) CONFIGURATION "Number of TCD in the System - inclusive in the scope of Supply 0
GAS CHROMATOGRAPH (GC) CONFIGURATION "Number of ECD in the System - inclusive in the scope of Supply 0
GAS CHROMATOGRAPH (GC) CONFIGURATION "Number of NPD/FTD in the System - inclusive in the scope of Supply 0
GAS CHROMATOGRAPH (GC) CONFIGURATION "Number of FPD in the System - inclusive in the scope of Supply 0
GAS CHROMATOGRAPH (GC) CONFIGURATION "Number of PID in the System - inclusive in the scope of Supply 0
GAS CHROMATOGRAPH (GC) CONFIGURATION "Number of PFPD in the System - inclusive in the scope of Supply 0
GAS CHROMATOGRAPH (GC) CONFIGURATION Number of Inlets GC can Simultaneously Support 2
GAS CHROMATOGRAPH (GC) CONFIGURATION Number of Detectors (Ports) GC can Simultaneously Support 4
GAS CHROMATOGRAPH (GC) CONFIGURATION Number of Capillary Columns provided in GC - inclusive in the scope of Supply 1
GAS CHROMATOGRAPH (GC) CONFIGURATION Type of Capillary Column Non-Polar
GAS CHROMATOGRAPH (GC) CONFIGURATION "GC Capillary Column Length 30.0
PERFORMANCE "GC Detector Minimum Detection Level (MDL) < 1.4 pg C/s for FID
COLUMN OVEN (GAS CHROMATOGRAPH - GC) Maximum Operating Temperature (GC Oven) upto 450 deg. C Or higher
COLUMN OVEN (GAS CHROMATOGRAPH - GC) Number of Oven Ramps / Plateaus for Temperature programming 20/21 or more
PNEUMATIC CONTROL Number of Injection Ports 2
PNEUMATIC CONTROL Maximum Injection Port heating Temperature upto 450 deg. C Or higher
PNEUMATIC CONTROL Pressure Range upto 140 psi Or higher
PNEUMATIC CONTROL Pressure set point Resolution (±)(psi) 0.001 Or lower
PNEUMATIC CONTROL Type of Sample Injection Port Split, Splitless, split / Splitless, Programmable Temperature Vaporizer (PTV)
PNEUMATIC CONTROL Split Ratio 7500:1
AUTO INJECTOR / AUTO SAMPLER Compatible Liquid Auto Sampler - inclusive in the scope of supply Yes
AUTO INJECTOR / AUTO SAMPLER Capacity of the Liquid Auto Sampler (Number of Vials) 150 Or higher
AUTO INJECTOR / AUTO SAMPLER Number of Injection Ports in the Liquid Auto Sampler 2
AUTO INJECTOR / AUTO SAMPLER Number of Channels in the Liquid Auto Sampler 2
AUTO INJECTOR / AUTO SAMPLER "Liquid Auto Sampler Features (Select applicable features Only)" Fully automated Liquid Auto Sampler, Injects with variable speed & varying syringe sizes, Operates through Software (Software inclusive in the scope of supply)
HEAD SPACE SAMPLER Compatible Head Space Sampler- inclusive in the scope of supply Yes
HEAD SPACE SAMPLER Capacity of the Head Space Sampler Carousel (number of Vials) 12 or better
HEAD SPACE SAMPLER Head Space Sampler Temperature Range Upto 200 deg. C or better
PYROLYZER SYSTEM Compatible Pyrolyzer System for pyrolysis of solid and liquid samples- inclusive in the scope of supply No
MASS SPECTROPHOTOMETER (MS-MS) SYSTEM Ionization modes Electron Ionization (EI)
MASS SPECTROPHOTOMETER (MS-MS) SYSTEM Detector Type Triple-Axis
MASS SPECTROPHOTOMETER (MS-MS) SYSTEM Operating modes Full Scan Mode, Selective Ion Monitoring (SIM) Mode, Both Full Scan & SIM Modes, Selective /Multiple Reaction Monitoring (SRM/MRM)
PERFORMANCE OF THE MASS SPECTROPHOTOMETER (MS-MS) SYSTEM Sensitivity (S/N Ratio) in full scan 1500:1 Or higher
PERFORMANCE OF THE MASS SPECTROPHOTOMETER (MS-MS) SYSTEM Sensitivity (S/N Ratio) in SRM/MRM 30000:1 Or higher
GENERIC Power Supply 230 V ± 10%
GENERIC Built-in Display Yes
GENERIC Provision to split the sample from single injection to two different detectors and get results for two detectors simultaneously No
GENERIC Back Flash - inclusive in the scope of supply Pre Column Back Flush, Post Column Back Flash, Mid Column Back Flash
SALIENT FEATURES OF GC-MS-MS "Salient Featutes of GC-MS (Select applicable features Only)" Automatic leak testing/detection of Pneumatics, Direct setting of split flow rates and ratios, Split and Septum Purge gases, Oven power turns-off automatically when the lid/door is opened, Over Heat Protection, Controlled by External PC System, EI source is inert to active compounds and programmable, Electron Impact ion source with dual filaments temperature up to 350 °C, Emission current should be able to set up to 300 µA or better, MRM/SRM Transitions should be 800 transitions/sec
LIBERARIES Libraries for GC-MS MRM data base Library, NIST Library for MS - Licensed version - 2017 or latest
SOFTWARE "Software Features (Select Applicable Features only)" Compatible with Windows 7 or higher version operating system, Seamless integration & control of all the GC parameters, Instrument diagnostics, Access to maintenance information, Access to maintenance, run and event logs, Retention Time - Locking module for analyzing target compounds in complex matrices
ACCESSORIES Gas Supply inclusive in the scope of supply Nitrogen, Argon, Helium
ACCESSORIES Number of Cyliners of each type supplied - inclusive in the scope of supply 2
ACCESSORIES Gas cylinders certified by PESO Yes
ACCESSORIES Regulator - inclusive in the scope of supply Dual Stage Regulator
ACCESSORIES "Other Accessories inclusive in the scope of supply (Select only those Accessories which are part of supply)" Gas purification panel for all Gases with moisture trap, Hydrocarbon trap & Oxygen trap, Auto Sampler Vials x 1000 vials with screw cap, Vessel ferrules x 10 nos, Septa for injector x 100 nos, Inlet liner for splitles x 4 nos, Inlet liner for split x 4 nos, O-rings x 10 nos. of each type, Tool Kit x 1 no., Syringe for Auto Sampler injection x 10 nos
DESKTOP WORKSTATION Desktop workstation Suitable to GC-MS - inclusive in the scope of supply Yes
DESKTOP WORKSTATION Graphics Card Memory Size 4.0
ONLINE UPS UPS Provided in the Scope of Supply Yes
ONLINE UPS Rating of online UPS(KVA) 10 KVA
ONLINE UPS Backup time of online UPS 60.0
INSTALLATION & COMMISSIONING / WARRANTY / AVAILABILITY OF SPARES / TRAINING Warranty on equipment 3.0
INSTALLATION & COMMISSIONING / WARRANTY / AVAILABILITY OF SPARES / TRAINING Number of days onsite training provided 3.0
CERTIFICATION / TEST REPORT "Availability of UL/CE Certificate as per EN 61010- 1:2010 Safety requirements for electrical equipment for measurement,control, and laboratory use General requirements" Yes
CERTIFICATION / TEST REPORT Conformance to EMC/EMI as per EN 61326-1:2013 Electrical equipment for measurement, control and laboratory use Yes
CERTIFICATION / TEST REPORT Availability of Test Reports from Central Govt / NABL approved / ILAC accredited Lab to prove conformity to the specification No

🤖 AI-Powered Bidder Prediction

Discover companies most likely to bid on this tender

Live AI
Historical Data

Required Documents

1

Experience Criteria

2

Past Performance

3

Bidder Turnover

4

Certificate (Requested in ATC)

5

OEM Authorization Certificate

6

OEM Annual Turnover

7

Additional Doc 1 (Requested in ATC)

8

Additional Doc 2 (Requested in ATC)

9

Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria

10

the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer

Similar Tenders

5 found

Forensic Science Laboratory GC-MS System Tender Delhi-North: IS 61010 Safety, EMI Compliance 2026

N/a

📍 NORTH DELHI, DELHI

EMD: ₹9.5 L
Est: ₹3.2 Cr
⏰ Deadline: 3 weeks left
🛒 Type: Goods
View GEM

Gas Chromatography

N/a

📍 KAMRUP, ASSAM

EMD: ₹2.4 L
Est: ₹1.2 Cr
⏰ Deadline: 3 weeks left
🛒 Type: Goods
View GEM

Assam Home And Political Department GC-MS Tender Kamrup 781001 ISI/EMC Compliant 2025

N/a

📍 KAMRUP, ASSAM

EMD: ₹8.0 L
Est: ₹4.0 Cr
⏰ Deadline: 3 weeks left
🛒 Type: Goods
View GEM

Gas Chromatography– Headspace (GC-HS) instrument

N/a

📍 NORTH DELHI, DELHI

EMD: ₹4.0 L
⏰ Deadline: 2 weeks left
🛒 Type: Goods
View GEM

Gas Chromatography

N/a

📍 LUCKNOW, UTTAR PRADESH

EMD: ₹40,000
⏰ Deadline: 2 weeks left
🛒 Type: Goods
View GEM