Rural Development Department Bihar High Mast Lighting Octagonal Tower LED Flood System Tender 2026
Rural Development Department
PURNIA, BIHAR
Bid Publish Date
22-Jan-2026, 1:23 pm
Bid End Date
12-Feb-2026, 1:00 pm
EMD
₹62,300
Location
Progress
Quantity
4
Bid Type
Two Packet Bid
Indo Tibetan Border Police (itbp) announces a tender for High Mast Lighting Tower for large area with LED Flood Lighting System (Q3) in SOUTH WEST DELHI, DELHI. Quantity: 4. Submission Deadline: 12-02-2026 13: 00: 00. Last date to apply is approaching fast!
Main Document
CATALOG Specification
GEM_GENERAL_TERMS_AND_CONDITIONS
Rural Development Department
PURNIA, BIHAR
Rural Development Department
PURNIA, BIHAR
Panchayati Raj Department
BEGUSARAI, BIHAR
Panchayati Raj Department
BEGUSARAI, BIHAR
Panchayati Raj Department
BEGUSARAI, BIHAR
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| GENERIC | Height of High Mast Tower (in Meters) | 25 |
| GENERIC | Installation and commissioning (Installation and commissioning work at multiple locations shall follow as per the guidelines of State/Central Govt rules and regulations as applicable) | Yes. Including Civil work at site |
| GENERIC | Onsite warranty (in Years) | 2 |
| High mast System | No of sections | 3 |
| High mast System | Effective length of each section (in m) | 10, 10.5 |
| High mast System | Material construction: The mast shall be manufactured using special steel plates, conforming to | 355 gradeasper BSEN10 025 |
| High mast System | Bottom diameter (in mm) - Minimum | 540 |
| High mast System | Plate thickness for Middle (in mm) - Minimum | 4 |
| High mast System | Plate thickness for Bottom (in mm) - Minimum | 5 |
| High mast System | No of longitudinal welds / section (in Nos) | 2, 1 |
| High mast System | Diameter of base plate (in mm) - Minimum | 740 |
| High mast System | Thickness of base plate (in mm) - Minimum | 30 |
| Wind Load | Maximum Wind load | 50 m/sec |
| Door Opening | Size of opening and closing door at base compartment of high mast (in mm) - Minimum | 1200 x 250 |
| Junction Box | Ingress protection for Junction Box i.e. IP Class (as per IS/IEC:60529:2001 latest) Test Report from Central Government lab/NABL/ILAC accrediated lab and report shall furnish to buyer on demand | IP 55 |
| Junction Box | No of core | 3 |
| Junction Box | Cable category | FR |
| Junction Box | Size of cable (in Sq mm) | 1.5 |
| Junction Box | Conductor material shall be | Copper |
| Winch | The winch shall have provision for manual operation in case of failure of the motor | Yes |
| Stainless Steel Wire Rope | The breaking load of each rope shall be at full load as per the relevant standard | >/=2400 Kg |
| Electrical System, Cable and Cable Connections | No. of cores | 1 |
| Electrical System, Cable and Cable Connections | Size of cable (in Sq.mm) | 2.5 |
| Electrical System, Cable and Cable Connections | Cable shall be | Unarmoured |
| Electrical System, Cable and Cable Connections | Conudctor material shall be | Copper |
| Electrical System, Cable and Cable Connections | Cable Category | 1 |
| Electrical System, Cable and Cable Connections | Incoming power cable from feeder panel to base compartment of mast and cable shall conforming to | IS:7098 (Part 1):1988 latest |
| Feeder pillar Panel | Feeder pillar panel for each mast | Yes |
| Feeder pillar Panel | Feeder panel shall be suitable for | 415 V, 3 phase, 4 wire, 50 Hz, AC |
| Feeder pillar Panel | The control panels shall be | Stand mounted |
| Feeder pillar Panel | Ingress protection for feeder pillar panel i.e IP Class (as per IS/IEC:60529:2001 latest).Test Report shall furnish from Central Government lab/NABL/ILAC accrediated lab to buyer on demand | IP 55 |
| Feeder pillar Panel | It shall be fabricated out of | 14 SWG CRCA sheet steel |
| Feeder pillar Panel | Thickness of sheet (in mm) | 2 |
| Feeder pillar Panel | The panels shall be given pre-treatment and powder coated and color shall be | Grey |
| Feeder pillar Panel | The stand shall be painted in | Black color |
| Feeder pillar Panel | Cable entry shall be at the | Bottom |
| Feeder pillar Panel | The panels shall have | knock outs of the required cable |
| Feeder pillar Panel | Laminated circuit diagram shall be pasted | inside of the door |
| Feeder pillar Panel | Feeder pillar shall have pad locking arrangement | Yes |
| Feeder pillar Panel | Earth terminal | 12 mm dia. Bolts |
| Feeder pillar Panel | Panel shall have a sloping cover to avoid accumulation of dust | Yes |
| Feeder pillar Panel | Panel shall be provided with incoming & outgoing MCCB / MCB of appropriate rating and in desired quantity depending on total no of circuits in use | yes |
| Feeder pillar Panel | Timer for automatic ON & OFF of lights with pilot lamps shall be provided | Yes |
| Feeder pillar Panel | Bus bars material | Yes. Copper |
| Feeder pillar Panel | No of Cores | 1 |
| Feeder pillar Panel | Cable Shall be | Unarmoured |
| Feeder pillar Panel | The conductor material shall be | Aluminium |
| Feeder pillar Panel | cable category | 1 |
| LED FLOOD LIGHT LUMINAIRE | No. of Luminaires for each high mast lighting tower (in Nos) | 12 |
| LED FLOOD LIGHT LUMINAIRE | LED Rating/System Wattage/Rated Power for each luminaire | 350W |
| LED FLOOD LIGHT LUMINAIRE | Luminaire System Efficacy (Lumen/watt) | >/= 100 Lm/Watt |
| LED FLOOD LIGHT LUMINAIRE | Ingress Protection (IP Rating) as per IS:10322 (Part 1):1982 latest | IP65 |
| LED FLOOD LIGHT LUMINAIRE | Mounting brackets (included) | Adjustable |
| LED FLOOD LIGHT LUMINAIRE | Input operating Voltage range and frequency | 90 to 300 Volts AC at 50Hz+/-2Hz |
| LED FLOOD LIGHT LUMINAIRE | Rated voltage | 230 V AC 50 Hz |
| LED FLOOD LIGHT LUMINAIRE | Colour temperature | 6000K (+/- 500K) |
| LED FLOOD LIGHT LUMINAIRE | Optic lense material (UV stabilised) (Write NA for without optic lense supply) | Poly carbonate lense |
| LED FLOOD LIGHT LUMINAIRE | Operating temperature range | -20 deg C to +50 deg C |
| LED FLOOD LIGHT LUMINAIRE | The luminaire shall be protected against surges and transients( Internal) | >/=5KV |
| LED FLOOD LIGHT LUMINAIRE | The luminaire shall be protected against surges and transients of >/=10KV (External) | Yes |
| LED FLOOD LIGHT LUMINAIRE | Extruded silicon loop gasket shall be provided in the lantern body to ensure a weather proof seal between the UV Glass cover and the metal housing to exclude the entry of the dust,water,insects etc | Yes |
| LED FLOOD LIGHT LUMINAIRE | Number of electronic control gear per luminaire (power supplies) | 1 No. |
| LED FLOOD LIGHT LUMINAIRE | Length of ISI marked three core wire (shall be provided along with supply of material) | 50 cm |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Annual Turnover *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
All India Institute Of Medical Sciences (aiims)
📍 JODHPUR, RAJASTHAN
N/a
📍 HARDOI, UTTAR PRADESH
Northern Railway
Central Agricultural University Imphal Manipur
📍 EAST SIANG, ARUNACHAL PRADESH
E-nagar Palika Government Of Madhya Pradesh
Sign up now to access all documents
Main Document
CATALOG Specification
GEM_GENERAL_TERMS_AND_CONDITIONS