Gondia District Panchayats Solar Power Plant Roof Top ONGRID Single Phase Procurement 2026
Gondia District Panchayats
GONDIA, MAHARASHTRA
Bid Publish Date
09-Feb-2026, 4:28 pm
Bid End Date
25-Feb-2026, 5:00 pm
EMD
₹2,96,000
Value
₹1,33,20,000
Progress
Quantity
2
Bid Type
Two Packet Bid
Office Of Dg (ls) invites bids for Automated HPLC System for Separation of complex mixtures (Q3). Quantity: 2. Submission Deadline: 25-02-2026 17: 00: 00. Submit your proposal before the deadline.
Main Document
OTHER
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Gondia District Panchayats
GONDIA, MAHARASHTRA
Seoni District Panchayats
SEONI, MADHYA PRADESH
Panchayati Raj Department
BEGUSARAI, BIHAR
Begusarai District Panchayats
BEGUSARAI, BIHAR
Begusarai District Panchayats
BEGUSARAI, BIHAR
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| Standard parameter | Instrument calibration standards | IEC 17025 |
| Quaternary Gradient Solvent Delivery Unit with Degassing Unit | Components of unit | Quaternary Low-Pressure Gradient pump& Parallel Double Plunger |
| Quaternary Gradient Solvent Delivery Unit with Degassing Unit | Number of solvents delivery | 4 |
| Quaternary Gradient Solvent Delivery Unit with Degassing Unit | Flow rate setting range in ml/min | 0.001 to 10 |
| Quaternary Gradient Solvent Delivery Unit with Degassing Unit | Flow rate accuracy | ± 1 % |
| UV-Vis Detector | UV-Vis Detector provided | Yes Or higher |
| UV-Vis Detector | Light source | Deuterium lamp |
| UV-Vis Detector | Spectrum Band width in nm | 4, 8 |
| UV-Vis Detector | Wavelength range in nm | 190 - 700 |
| UV-Vis Detector | Sampling Rate in Hz | 100 |
| UV-Vis Detector | The flow cell must be temperature Controlled | Yes |
| UV-Vis Detector | Wavelength accuracy in nm | ± 1 |
| UV-Vis Detector | Wavelength reproducibility in nm | ± 0.1 |
| UV-Vis Detector | Drift in AU/Hour | less than 1 x 10-4 |
| UV-Vis Detector | Noise level in AU | ± 2.5 x 10-6 |
| UV-Vis Detector | Ability to monitor and quantitative 2 wavelengths simultaneously | Yes |
| UV-Vis Detector | Linearity in AU | 2.5 or more |
| UV-Vis Detector | Temperature control provided for Flow cell | Yes |
| UV-Vis Detector | Temperature control range for flow cell in Degree Celsius | 5 degree above room temp to 50 degree |
| UV-Vis Detector | flow cell path length in mm | 10 |
| UV-Vis Detector | Flow cell volume in ?l | 10 - 15 |
| Auto Sample Injector with cooler | Injection Method | Total volume sample injection |
| Auto Sample Injector with cooler | Carry over of sample | 0.005% or lower |
| Auto Sample Injector with cooler | Injection precision in RSD | less than 0.20 % RSD |
| Software | Operating Windows | Win 10 or latest |
| Photo Diode Array (PDA) Detector | Provision of Photo diode array | Yes Or higher |
| Photo Diode Array (PDA) Detector | PDA detector Wavelength range in nm | 190- 800 or better |
| Photo Diode Array (PDA) Detector | Number of Diodes | 1024 |
| Photo Diode Array (PDA) Detector | PDA detector light source | Deuterium lamp and Tungsten lamp |
| Photo Diode Array (PDA) Detector | PDA detector Wavelength accuracy in nm | ± 1 |
| Photo Diode Array (PDA) Detector | Data Rate in Hz | 100, <100 |
| Photo Diode Array (PDA) Detector | Noise in AU | less than ± 0.6 x 10-5 or lower |
| Photo Diode Array (PDA) Detector | PDA detector Drift in AU/Hour | less than 1 x 10-3 |
| Photo Diode Array (PDA) Detector | Temperature controlled flow cell in C | 5 degree above room temp to 50 degree |
| Photo Diode Array (PDA) Detector | Flow cell | Flow cell |
| Warranty & Reports | Warranty (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) | 3, 4, 5 Or higher |
| Warranty & Reports | Number of installations in Central /State/PSU Govt Hospitals | <3, >3 |
| Warranty & Reports | Availability of toll free facility for technical support maintained by OEM or authorized agencies | Yes Or higher |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
OEM Authorization Certificate
OEM Annual Turnover
Additional Doc 1 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
N/a
📍 MUMBAI, MAHARASHTRA
Indo Tibetan Border Police (itbp)
📍 DEHRADUN, UTTARAKHAND
Jawaharlal Institute Of Postgraduate Medical Education And Research (jipmer)
📍 PONDICHERRY, PUDUCHERRY
Directorate Of Medical Education And Training
📍 SHAHJAHANPUR, UTTAR PRADESH
National Institute Of Criminology And Forensic Science (nicfs)
📍 WEST DELHI, DELHI
Sign up now to access all documents
Main Document
OTHER
CATALOG Specification
ATC