Ultrasound Machine (V2)
N/a
Progress
Quantity
1
Bid Type
Two Packet Bid
The Gujarat Health & Family Welfare Department invites bids for an Ultrasound Machine (V2) to be deployed in Jamnagar, Gujarat 360510. Estimated contract value is ₹12,00,000 with an EMD of ₹35,000. The procurement requires an expansive probe ecosystem including Convex, Microconvex, Linear, TVS, Cardiac, Hockey Stick, Volume variants, plus specialized elastography capabilities and 3-D/4-D imaging. Key differentiators include a broad scan-mode portfolio (contrast harmonic, harmonic imaging in probes, color and power Doppler, triplex, tissue Doppler, CEUS option) and robust image processing with DICOM 3 compliance, PC interfacing, and digital storage. This is a government tender aimed at a comprehensive ultrasound solution with extensive compatibility and upgrade potential.
Ultrasound system with full probe portfolio including Convex, Microconvex, Linear, TVS, Cardiac, Hockey Stick, Volume Convex, Volume Linear, Volume TVS, Endorectal
Elastography capabilities: E-Breast, E-Thyroid, Liver elastography
Imaging: Contrast harmonic imaging with angio mode, Color Doppler, Power Doppler, 3-D/4-D options, tissue colorization (B-Colour), frame grabber
Display/storage: Touch Screen, monitor size, PC interfaced with USG, RAM/processor specs, digital storage, USB/DVD compatibility, DICOM to PACS/RIS
Power: back-up time and stabilizer/CVT; suitable surge protection; power requirements clearly defined
EMD of ₹35,000 required with bid submission
Quantity may vary by ±25% during contract with extended delivery time rules
Bid must ensure DICOM 3 compliance and PACS/RIS interfacing
Not specified in data; bidders should expect standard government terms; ensure bid includes EMD and any advance/payment schedule aligned with contract
Delivery period tied to last date of original delivery order; additional time calculated as (Increased quantity ÷ Original quantity) × Original delivery period, minimum 30 days
Not detailed in provided data; bidders should anticipate standard LDs for delayed delivery per government tender norms
Proven experience in supplying ultrasound equipment to government or large health facilities
Financial capacity with audited statements demonstrating liquidity
Compliance with DICOM 3 standards and PACS/RIS integration experience
N/a
Assam Medical Services Corporation Limited
KAMRUP, ASSAM
N/a
SOUTH TRIPURA, TRIPURA
Hll Lifecare Limited
THIRUVANANTHAPURAM, KERALA
N/a
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| Types of Probes & Features | Convex Probe | 2.5 to 5 MHz (±2) |
| Types of Probes & Features | Microconvex probe | Not Provided |
| Types of Probes & Features | Linear array probe | 3 to 12 MHz (±2) |
| Types of Probes & Features | TVS Probe | Not Provided |
| Types of Probes & Features | Cardiac Probe | Not Provided |
| Types of Probes & Features | Hockey Stick Probe | Not Provided |
| Types of Probes & Features | Volume Convex Probe | Not Provided |
| Types of Probes & Features | Volume Linear Probe | Not Provided |
| Types of Probes & Features | Volume TVS Probe | Not Provided |
| Types of Probes & Features | Endorectal Probe | Not Provided |
| Types of Probes & Features | E-Breast Elastography technique | Yes |
| Types of Probes & Features | E-Thyroid Elastography technique | Yes |
| Types of Probes & Features | Liver Elastography technique | No |
| Types of Probes & Features | Gel Warmer | No |
| Types of Probes & Features | Dedicated 3-D/4-D | Yes |
| Scan Modes | Contrast harmonic imaging with angio mode | No |
| Scan Modes | Provision of Harmonic imaging in Linear Probes | Yes |
| Scan Modes | Color Doppler imaging (CDI) | Yes |
| Scan Modes | Color Doppler 3-D/4-D option | Yes |
| Scan Modes | Power Doppler imaging (PDI) | Yes |
| Scan Modes | Power Doppler 3-D/4-D option | Yes |
| Scan Modes | Continuous wave | Yes |
| Scan Modes | Triplex mode | Yes |
| Scan Modes | Tissue Doppler imaging | Yes |
| Scan Modes | Contrast-enhanced ultrasound (CEUS) option | No |
| Scan Modes | Tissue synchronization, tissue velocity | Yes |
| Scan Modes | Provision for higher sensitivity for low frequency doppler in all probes | Yes |
| Scan Modes | Number of channels in color doppler system | 2500000 or more (if channels are being designated as digital channels) |
| Scan Modes | Live 3 D imaging in color doppler system | No |
| Scan Modes | Colour Doppler system with all application packages ,Quad loop for serial studies with high frame rate revies, harmonic imaging capability in all modes and integrated stress echo package digital storage and retrieval | Yes |
| Scan Modes | Provision of Tissue Colorization (B-Colour) for improved contrast resolution | Yes |
| Scan Modes | Cine Loop Features | Yes |
| Scan Modes | Frame grabber facility for post analysis | Yes |
| Scan Modes | Number of transducer/probe ports | 4 or More |
| Scan Modes | System should be capable of generating real time live 3- D images | Yes |
| Scan Modes | Contrast agent imaging | No |
| Image Display and Processing | DICOM 3 Compliant | Yes |
| Image Display and Processing | Automated B-mode (2-D) image | Yes |
| Image Display and Processing | Automated CDI(Color Doppler Imaging) image optimization | Yes |
| Image Display and Processing | Automated PW Doppler image optimization | Yes |
| Image Display and Processing | Touch Screen | No |
| Image Display and Processing | Monitor display size (inch) | 17 or more, 19 or more, 21 or more Or higher |
| Image Display and Processing | Split screen | Twin View |
| Image Display and Processing | Single/dual monitors | Single |
| Image Display and Processing | Max number frames | >=1000 |
| Image Display and Processing | Digital storage hard drive, GB | >=500 |
| Image Display and Processing | DVD/CD Writer/ USB | Yes |
| Image Display and Processing | Type of processor (in PC) | NA |
| Image Display and Processing | RAM capacity of PC in GB (hint: In case PC not provided put zero) | NA |
| Image Display and Processing | Processor speed in GHz (PC) | NA |
| Image Display and Processing | Frame Grabber incorporated(PC) | Yes |
| Image Display and Processing | Connectivity between USG and PC | Yes |
| Image Display and Processing | PC with all software inclusive interfaced with USG machine | No |
| Image Display and Processing | Laser Color printer provided | No |
| Image Display and Processing | Inkjet/Thermal printer provided | No |
| Image Display and Processing | CD/DVD/USB Produced should be playable on any system | Yes |
| Image Display and Processing | Glossy Colour Print Paper supplied | NA |
| Image Display and Processing | Dicom Interfacability Dicom to PACS | Yes |
| Image Display and Processing | Interfacability Dicom to RIS | Yes |
| Power Requirements | Resettable over current breaker shall be fitted for protection | Yes |
| Power Requirements | Power backup | UPS |
| Power Requirements | Back up time in minutes (minimum) | 30.0 |
| Power Requirements | Suitable Servo Controlled Stabilizer / CVT should be provided | No |
| Warranty and Maintenance | Warranty in Years (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) | 3, 5 Or higher |
Discover companies most likely to bid on this tender
GST registration certificate
PAN card
Experience certificates showing prior ultrasound equipment supply
Financial statements (last 3 years)
EMD document evidencing ₹35,000
Technical bid documents demonstrating DICOM 3 compliance and probe compatibility
OEM authorization letters (if applicable)
Product technical specifications and warranty details
Key insights about GUJARAT tender market
To bid, register with the procuring entity, obtain the bid documents, submit EMD of ₹35,000, provide GST/PAN, experience certificates, financial statements, OEM authorizations if required, and demonstrate DICOM 3 compliance plus the full probe set and imaging features listed. Ensure delivery within the extended schedule if quantity changes.
Submit GST certificate, PAN card, last 3 years financials, experience certificates for similar projects, EMD receipt of ₹35,000, technical bid with DICOM compliance, OEM authorizations, and detailed specifications for the proposed ultrasound system and probes.
System must support a broad probe family (Convex, Linear, Endorectal, Elastography-capable probes), DICOM 3 compatibility, PC interfacing, 3-D/4-D imaging, CEUS option, and advanced Doppler modes (CDI/PDI). Storage: digital drive, USB, and RIS/PACS interoperability.
Delivery terms follow the last date of the original delivery order with possible extension using the option clause; additional time calculated as (increased quantity/original quantity) × original delivery period, minimum 30 days, subject to contract terms.
EMD required is ₹35,000. Payment terms are not explicitly stated here; bidders should align with standard government practices, including submission of compliant invoices and delivery verification, while the EMD remains a security with bid validity.
The tender requests an extensive probe portfolio: Convex, Microconvex, Linear, TVS, Cardiac, Hockey Stick, Volume variants, Endorectal, and Elastography-enabled probes for E-Breast/Thyroid/Liver, plus dedicated 3-D/4-D capabilities and harmonic imaging features.
System must be DICOM 3 Compliant with imaging storage, and capable of interfacing with PACS/RIS; ensure integration through PC connectivity, and data should be retrievable for post-analysis via cine loop and frame grabber features.
The tender allows a comprehensive warranty option accessible through bidding; if selected, this warranty supersedes the standard catalogue warranty, providing extended coverage and service terms for the ultrasound system and probes.
All India Institute Of Medical Sciences (aiims)
📍 KAMRUP, ASSAM
Assam Medical College And Hospital Borbari Dibrugarh
📍 DIBRUGARH, ASSAM
All India Institute Of Medical Sciences (aiims)
📍 JODHPUR, RAJASTHAN
Indian Army
📍 BIKANER, RAJASTHAN
All India Institute Of Medical Sciences (aiims)
📍 JODHPUR, RAJASTHAN
Sign up now to access all documents
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS