Ultrasound Machine (V2)
Employees State Insurance Corporation
EAST GODAVARI, ANDHRA PRADESH
Bid Publish Date
07-Feb-2026, 11:20 am
Bid End Date
28-Feb-2026, 12:00 pm
EMD
₹20,000
Location
Progress
Quantity
1
Bid Type
Two Packet Bid
Aligarh Muslim University (AMU) in Aligarh, Uttar Pradesh invites bids for a comprehensive Ultrasound Machine (V2) package featuring an extensive set of transducers (Convex, Microconvex, Linear, TVS, Cardiac, Hockey Stick, Volume variants, Endorectal), elastography capabilities (E-Breast, E-Thyroid, Liver), gel warmer, dedicated 3-D/4-D, and advanced scan modes including Contrast Harmonic Imaging, DICOM 3 Compliant workflow, tissue Doppler, and stress echo integration. The scope emphasizes high-end imaging with multi-probe compatibility, real-time 3D color Doppler, and PACS/RIS interfacing. The project lists an EMD of ₹20,000 and targets robust, service-backed supply for a university setting. Unique differentiators include comprehensive software packages, high frame-rate reviews, and full PC interfacing with USG. This tender focuses on procuring a turnkey ultrasound system capable of advanced research and clinical teaching.
Ultrasound system with comprehensive probe set including convex, microconvex, linear, TVS, cardiac, hockey stick and volume variants
Elastography modules: E-Breast, E-Thyroid, Liver elastography
Imaging: Harmonic imaging, CEUS option, tissue Doppler, 3D/4D live imaging, color Doppler, triplex mode
Display/Storage: DICOM 3 compliant, touch screen, multi-monitor support, PC interfaced with USG system, digital storage HDD, USB/DVD printing
Power: Stabilizer/CVT, backup duration in minutes; resettable breaker protection
EMD of ₹20,000; delivery terms allow up to 25% quantity variation
GST payable by bidder; reimbursement as actuals or applicable rate
OEM/Authorized Seller with registered India presence for imported equipment
Dedicated service line and escalation matrix must be provided
All required certificates must be uploaded; non-submission leads to rejection
GST handling by bidder; payment processed per ATC; no dates specified in data
Option clause allows 25% quantity variation; delivery period starts from last order date with minimum 30 days if extended
Not explicitly detailed in data; penalties typically apply for delays per ATC
Experience in supplying advanced ultrasonic systems to educational institutions
Demonstrable after-sales support footprint in India
Financial stability and GST registration in India
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Employees State Insurance Corporation
EAST GODAVARI, ANDHRA PRADESH
N/a
KANGRA, HIMACHAL PRADESH
N/a
BILASPUR, CHHATTISGARH
N/a
Goa Shipyard Limited
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| Types of Probes & Features | Convex Probe | 2.5 to 5 MHz (±2), Not Provided |
| Types of Probes & Features | Microconvex probe | 4 to 8 MHz (±2), Not Provided |
| Types of Probes & Features | Linear array probe | 5 to 10 MHz (±2), 3 to 12 MHz (±2), 6 to 15 MHz (±2), 6 to 18 MHz (±2), Not provided |
| Types of Probes & Features | TVS Probe | 4 to 9 MHz (±2), Not Provided |
| Types of Probes & Features | Cardiac Probe | 1 to 5 MHz (±2), 5 to 9 MHz (±2), Not Provided |
| Types of Probes & Features | Hockey Stick Probe | 6 to 17 MHz (±2), 6 to 13 MHz (±2), 8 to 20 MHz (±2), Not Provided |
| Types of Probes & Features | Volume Convex Probe | 2.5 to 5 MHz (±2), Not Provided |
| Types of Probes & Features | Volume Linear Probe | 3 to 12 MHz (±2), 6 to 15 MHz (±2), 6 to 18 MHz (±2), 5 to 10 MHz (±2), Not Provided |
| Types of Probes & Features | Volume TVS Probe | 4 to 9 MHz (±2), Not Provided |
| Types of Probes & Features | Endorectal Probe | 5 to 9 MHz (±2), Not Provided |
| Types of Probes & Features | E-Breast Elastography technique | Yes, No |
| Types of Probes & Features | E-Thyroid Elastography technique | Yes, No |
| Types of Probes & Features | Liver Elastography technique | Yes, No |
| Types of Probes & Features | Gel Warmer | Yes, No |
| Types of Probes & Features | Dedicated 3-D/4-D | Yes, No |
| Scan Modes | Contrast harmonic imaging with angio mode | Yes, No |
| Scan Modes | Provision of Harmonic imaging in Linear Probes | Yes, No |
| Scan Modes | Color Doppler imaging (CDI) | Yes, No |
| Scan Modes | Color Doppler 3-D/4-D option | Yes, No |
| Scan Modes | Power Doppler imaging (PDI) | Yes, No |
| Scan Modes | Power Doppler 3-D/4-D option | Yes, No |
| Scan Modes | Continuous wave | Yes, No |
| Scan Modes | Triplex mode | Yes, No |
| Scan Modes | Tissue Doppler imaging | Yes, No |
| Scan Modes | Contrast-enhanced ultrasound (CEUS) option | Yes, No |
| Scan Modes | Tissue synchronization, tissue velocity | Yes, No |
| Scan Modes | Provision for higher sensitivity for low frequency doppler in all probes | Yes, No |
| Scan Modes | Number of channels in color doppler system | 50000 or more (if channels are being designated as digital channels), 300000 or more (if channels are being designated as digital channels), 1000000 or more (if channels are being designated as digital channels), 2500000 or more (if channels are being designated as digital channels), 4000000 or more (if channels are being designated as digital channels), 128 or more (if channels are being designated as physical channels) |
| Scan Modes | Live 3 D imaging in color doppler system | Yes, No |
| Scan Modes | Colour Doppler system with all application packages ,Quad loop for serial studies with high frame rate revies, harmonic imaging capability in all modes and integrated stress echo package digital storage and retrieval | Yes, No |
| Scan Modes | Provision of Tissue Colorization (B-Colour) for improved contrast resolution | Yes, No |
| Scan Modes | Cine Loop Features | Yes, No |
| Scan Modes | Frame grabber facility for post analysis | Yes, No |
| Scan Modes | Number of transducer/probe ports | 2, 3, 4 or More |
| Scan Modes | System should be capable of generating real time live 3- D images | Yes, No |
| Scan Modes | Contrast agent imaging | Yes, No |
| Image Display and Processing | DICOM 3 Compliant | Yes, No |
| Image Display and Processing | Automated B-mode (2-D) image | Yes, No |
| Image Display and Processing | Automated CDI(Color Doppler Imaging) image optimization | Yes, No |
| Image Display and Processing | Automated PW Doppler image optimization | Yes, No |
| Image Display and Processing | Touch Screen | Yes, No |
| Image Display and Processing | Monitor display size (inch) | 15 or more, 17 or more, 19 or more, 21 or more Or higher |
| Image Display and Processing | Split screen | Twin View, Twin View and Live Quad Screen, No |
| Image Display and Processing | Single/dual monitors | Single, Single with optional second console, Dual (image display and touch panel) |
| Image Display and Processing | Max number frames | >=1000, >=500 |
| Image Display and Processing | Digital storage hard drive, GB | >=500, >=200 or more |
| Image Display and Processing | DVD/CD Writer/ USB | Yes, No |
| Image Display and Processing | Type of processor (in PC) | i7 or latest, NA |
| Image Display and Processing | RAM capacity of PC in GB (hint: In case PC not provided put zero) | ≥ 4, NA |
| Image Display and Processing | Processor speed in GHz (PC) | ≥ 3, NA |
| Image Display and Processing | Frame Grabber incorporated(PC) | Yes, No |
| Image Display and Processing | Connectivity between USG and PC | Yes, No |
| Image Display and Processing | PC with all software inclusive interfaced with USG machine | Yes, No |
| Image Display and Processing | Laser Color printer provided | Yes, No |
| Image Display and Processing | Inkjet/Thermal printer provided | Yes, No |
| Image Display and Processing | CD/DVD/USB Produced should be playable on any system | Yes, No |
| Image Display and Processing | Glossy Colour Print Paper supplied | 500 sheets, 1000 sheets, NA |
| Image Display and Processing | Dicom Interfacability Dicom to PACS | Yes, No |
| Image Display and Processing | Interfacability Dicom to RIS | Yes, No |
| Power Requirements | Resettable over current breaker shall be fitted for protection | Yes, No |
| Power Requirements | Power backup | UPS, Inbuilt battery |
| Power Requirements | Back up time in minutes (minimum) | 30, 60, 90, 120 |
| Power Requirements | Suitable Servo Controlled Stabilizer / CVT should be provided | Yes, No |
| Warranty and Maintenance | Warranty in Years (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) | 3, 5 Or higher |
Discover companies most likely to bid on this tender
GST registration certificate
PAN card
Experience certificates of similar ultrasound system supply
Financial statements (audited)</n>
EMD deposit receipt (₹20,000)
Technical bid/documentation proving system capabilities
OEM authorization or authorized seller confirmation
After-sales service proof (toll-free number, escalation matrix)
Extended Deadline
28-Feb-2026, 12:00 pm
Opening Date
28-Feb-2026, 12:30 pm
Key insights about UTTAR PRADESH tender market
Bidders must register on the portal, submit EMD of ₹20,000, GST details, PAN, and experience certificates. Provide OEM authorization for imported models and upload full technical bid with DICOM 3 compliance proofs, 3D/4D capabilities, and elastography modules. Prepare support contact details.
Required documents include GST certificate, PAN, audited financial statements, experience certificates for similar ultrasound systems, EMD receipt of ₹20,000, OEM authorization, technical bid, and service support proof with toll-free number and escalation matrix.
System must support convex, microconvex, linear, TVS probes, elastography (E-Breast, E-Thyroid, Liver), harmonic imaging, CEUS option, 3D/4D live imaging, DICOM 3 compliant, color Doppler, triplex mode, and PACS/RIS interfacing with PC compatibility.
Delivery window aligns with the option clause; quantity may vary up to 25%, and the extended period begins after the last order date with minimum 30 days; exact date to be finalized in the purchase order.
EMD is ₹20,000. GST handling is the bidder’s responsibility; payment terms are per ATC with supplier responsibilities clearly defined; imported equipment require Indian OEM after-sales service documentation.
Bid must show dedicated service line and escalation matrix; OEM/authorized seller must provide India-based after-sales support; comprehensive warranty option is available via bidding and may supersede catalogue terms if chosen.
System must be DICOM 3 compliant, with 3D/4D imaging, PCI/PACS interoperability, and ISO/quality considerations; elastography modules and harmonic imaging must meet industry norms; ensure ISI/ISO certifications if applicable per ATC.
N/a