Ultrasound Machine (V2)
N/a
BILASPUR, CHHATTISGARH
Bid Publish Date
19-Feb-2026, 7:44 pm
Bid End Date
02-Mar-2026, 8:00 pm
EMD
₹1,00,000
Location
Progress
Quantity
1
Bid Type
Two Packet Bid
The Health and Family Welfare Department, Tripura invites procurement of an advanced Ultrasound Machine (V2) for SOUTH TRIPURA, Tripura 799013. The scope spans a broad array of transducers including Convex, Linear, Microconvex, Cardiac, Hockey Stick, Endorectal, E-Breast Elastography, E-Thyroid Elastography, Liver Elastography, Volume probes, 3-D/4-D capability, and comprehensive scan modes such as Contrast Harmonic Imaging, CDI, PDI, Triplex, Tissue Doppler, CEUS, and live 3-D imaging. Estimated value is not disclosed; EMD is ₹100000. The BOQ shows diverse imaging features, high frame-rate, RAM/PC integration, DICOM, RIS/PACS interfacability, and a printer/Storage suite. This tender targets hospitals and health facilities in SOUTH TRIPURA seeking a turnkey ultrasound platform with full software packages and diagnostic versatility.
Broad probe compatibility including Convex, Linear, Cardiac, Endorectal and Volume probes
Elastography features: E-Breast, E-Thyroid, Liver Elastography
Advanced imaging modes: CEUS, Harmonic imaging, Triplex, Tissue Doppler, PDI, CDI
DICOM 3 compliant with RIS/PACS interfacing and report generation
Live 3-D imaging, high frame-rate color Doppler, cine loop and frame grabber
PC integration with RAM/processor specs and USB/DVD writer; printer support
EMD of ₹100,000 must be submitted with bidder response
Quantity may be increased/decreased by up to 25% during contract
Delivery timeline subject to option clause and 30-day minimum extension
Comprehensive warranty option available via bidding
Not explicitly defined; bidders should anticipate milestone-based or upfront terms per contract and ensure alignment with government procurement norms.
Option clause allows ±25% quantity variation; delivery period calculated from last date of original delivery order with possible extension and minimum 30 days.
Not specified; bidders should assume standard LD provisions for delays and non-conformances as per governing policies.
Experience in supplying advanced ultrasound systems with multiple probes
Demonstrated financial capability to handle high-value medical equipment
OEM authorization for ultrasound platform and software
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
N/a
BILASPUR, CHHATTISGARH
N/a
Goa Shipyard Limited
Oil India Limited
DIBRUGARH, ASSAM
N/a
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| Types of Probes & Features | Convex Probe | 2.5 to 5 MHz (±2), Not Provided |
| Types of Probes & Features | Microconvex probe | 4 to 8 MHz (±2), Not Provided |
| Types of Probes & Features | Linear array probe | 5 to 10 MHz (±2), 3 to 12 MHz (±2), 6 to 15 MHz (±2), 6 to 18 MHz (±2), Not provided |
| Types of Probes & Features | TVS Probe | 4 to 9 MHz (±2), Not Provided |
| Types of Probes & Features | Cardiac Probe | 1 to 5 MHz (±2), 5 to 9 MHz (±2), Not Provided |
| Types of Probes & Features | Hockey Stick Probe | 6 to 17 MHz (±2), 6 to 13 MHz (±2), 8 to 20 MHz (±2), Not Provided |
| Types of Probes & Features | Volume Convex Probe | 2.5 to 5 MHz (±2), Not Provided |
| Types of Probes & Features | Volume Linear Probe | 3 to 12 MHz (±2), 6 to 15 MHz (±2), 6 to 18 MHz (±2), 5 to 10 MHz (±2), Not Provided |
| Types of Probes & Features | Volume TVS Probe | 4 to 9 MHz (±2), Not Provided |
| Types of Probes & Features | Endorectal Probe | 5 to 9 MHz (±2), Not Provided |
| Types of Probes & Features | E-Breast Elastography technique | Yes, No |
| Types of Probes & Features | E-Thyroid Elastography technique | Yes, No |
| Types of Probes & Features | Liver Elastography technique | Yes, No |
| Types of Probes & Features | Gel Warmer | Yes, No |
| Types of Probes & Features | Dedicated 3-D/4-D | Yes, No |
| Scan Modes | Contrast harmonic imaging with angio mode | Yes, No |
| Scan Modes | Provision of Harmonic imaging in Linear Probes | Yes, No |
| Scan Modes | Color Doppler imaging (CDI) | Yes, No |
| Scan Modes | Color Doppler 3-D/4-D option | Yes, No |
| Scan Modes | Power Doppler imaging (PDI) | Yes, No |
| Scan Modes | Power Doppler 3-D/4-D option | Yes, No |
| Scan Modes | Continuous wave | Yes, No |
| Scan Modes | Triplex mode | Yes, No |
| Scan Modes | Tissue Doppler imaging | Yes, No |
| Scan Modes | Contrast-enhanced ultrasound (CEUS) option | Yes, No |
| Scan Modes | Tissue synchronization, tissue velocity | Yes, No |
| Scan Modes | Provision for higher sensitivity for low frequency doppler in all probes | Yes, No |
| Scan Modes | Number of channels in color doppler system | 50000 or more (if channels are being designated as digital channels), 300000 or more (if channels are being designated as digital channels), 1000000 or more (if channels are being designated as digital channels), 2500000 or more (if channels are being designated as digital channels), 4000000 or more (if channels are being designated as digital channels), 128 or more (if channels are being designated as physical channels) |
| Scan Modes | Live 3 D imaging in color doppler system | Yes, No |
| Scan Modes | Colour Doppler system with all application packages ,Quad loop for serial studies with high frame rate revies, harmonic imaging capability in all modes and integrated stress echo package digital storage and retrieval | Yes, No |
| Scan Modes | Provision of Tissue Colorization (B-Colour) for improved contrast resolution | Yes, No |
| Scan Modes | Cine Loop Features | Yes, No |
| Scan Modes | Frame grabber facility for post analysis | Yes, No |
| Scan Modes | Number of transducer/probe ports | 2, 3, 4 or More |
| Scan Modes | System should be capable of generating real time live 3- D images | Yes, No |
| Scan Modes | Contrast agent imaging | Yes, No |
| Image Display and Processing | DICOM 3 Compliant | Yes, No |
| Image Display and Processing | Automated B-mode (2-D) image | Yes, No |
| Image Display and Processing | Automated CDI(Color Doppler Imaging) image optimization | Yes, No |
| Image Display and Processing | Automated PW Doppler image optimization | Yes, No |
| Image Display and Processing | Touch Screen | Yes, No |
| Image Display and Processing | Monitor display size (inch) | 15 or more, 17 or more, 19 or more, 21 or more Or higher |
| Image Display and Processing | Split screen | Twin View, Twin View and Live Quad Screen, No |
| Image Display and Processing | Single/dual monitors | Single, Single with optional second console, Dual (image display and touch panel) |
| Image Display and Processing | Max number frames | >=1000, >=500 |
| Image Display and Processing | Digital storage hard drive, GB | >=500, >=200 or more |
| Image Display and Processing | DVD/CD Writer/ USB | Yes, No |
| Image Display and Processing | Type of processor (in PC) | i7 or latest, NA |
| Image Display and Processing | RAM capacity of PC in GB (hint: In case PC not provided put zero) | ≥ 4, NA |
| Image Display and Processing | Processor speed in GHz (PC) | ≥ 3, NA |
| Image Display and Processing | Frame Grabber incorporated(PC) | Yes, No |
| Image Display and Processing | Connectivity between USG and PC | Yes, No |
| Image Display and Processing | PC with all software inclusive interfaced with USG machine | Yes, No |
| Image Display and Processing | Laser Color printer provided | Yes, No |
| Image Display and Processing | Inkjet/Thermal printer provided | Yes, No |
| Image Display and Processing | CD/DVD/USB Produced should be playable on any system | Yes, No |
| Image Display and Processing | Glossy Colour Print Paper supplied | 500 sheets, 1000 sheets, NA |
| Image Display and Processing | Dicom Interfacability Dicom to PACS | Yes, No |
| Image Display and Processing | Interfacability Dicom to RIS | Yes, No |
| Power Requirements | Resettable over current breaker shall be fitted for protection | Yes, No |
| Power Requirements | Power backup | UPS, Inbuilt battery |
| Power Requirements | Back up time in minutes (minimum) | 30, 60, 90, 120 |
| Power Requirements | Suitable Servo Controlled Stabilizer / CVT should be provided | Yes, No |
| Warranty and Maintenance | Warranty in Years (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) | 3, 5 Or higher |
Discover companies most likely to bid on this tender
GST registration certificate
PAN card
Experience certificates for prior ultrasound equipment supply
Financial statements / solvency certificate
EMD submission document for ₹100,000
Technical bid with device specifications and OEM authorization
OEM authorization letter for the ultrasound system
Compliance certificates (DICOM, ISI/ISO if applicable)
Key insights about TRIPURA tender market
Bidders must submit the EMD of ₹100000, GST and PAN, experience certificates, financial statements, OEM authorization, and technical bid with device specifications. Ensure DICOM 3 compliance, RIS/PACS interfacing, and elastography capabilities. Follow option clause rules for quantity variation and prepare for extended delivery timelines.
Required documents include GST certificate, PAN card, experience certificates for ultrasound supply, financial statements, EMD submission document, OEM authorization, and detailed technical bid showing probes (Convex, Linear, Cardiac, Endorectal) and elastography features; ensure DICOM compliance.
System must support Convex, Microconvex, Linear, TVS, Cardiac, Hockey Stick, Volume probes, Elastography (E-Breast, E-Thyroid, Liver), CEUS, Harmonic imaging, PDI, CDI, 3-D/4-D with live imaging, DICOM 3 compliance, RIS/PACS interfacing, and frame grabber/Cine Loop features.
Delivery is governed by the option clause allowing ±25% quantity change; the extended delivery period is calculated from the original delivery date with a minimum 30-day extension; exact dates are defined at contract award.
Payment terms are not explicitly specified; bidders should prepare for standard government practice, potentially milestone-based payments linked to delivery milestones and acceptance testing per contract.
A comprehensive warranty option is available via bidding and, if chosen, will supersede the catalogue warranty; ensure the supplier provides service coverage and response times as part of the bid.
EMD is ₹100000; bidders must submit this amount through the prescribed instrument (DD/online as applicable) along with the bid to qualify for technical evaluation and bid validity.
Ensure the proposed ultrasound system is DICOM 3 compliant and can interface with RIS/PACS; verify software compatibility, test patient data transfer, and provide documentation confirming DICOM conformance and RIS/PACS integration.
All India Institute Of Medical Sciences (aiims)
📍 GORAKHPUR, UTTAR PRADESH
Aligarh Muslim University (amu)
📍 ALIGARH, UTTAR PRADESH
U.p.rural Institute Of Medical Sciences And Research Saifai
📍 ETAWAH, UTTAR PRADESH
N/a
📍 SRINAGAR, JAMMU & KASHMIR
Directorate Of Medical And Rural Health Services
📍 BUDGAM, JAMMU & KASHMIR
Sign up now to access all documents
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS