TenderDekho Logo
Refrigeration System state-wide in Andaman & Nicobar

Refrigeration System Tenders in Andaman & Nicobar

Access live Refrigeration System procurement tenders in Andaman & Nicobar state. Top buyer: E-IN-C BRANCH - MILITARY ENGINEER SERVICES. Combined opportunity value of ₹1.6 lakh. Key locations: South Andamans

Location
Major Buyer
0

Face Mask for Underwater Training,Leg Fins for Underwater Training,Wet Suit for Training,Buoyancy C

Hqids

SOUTH ANDAMANS, ANDAMAN & NICOBARPosted 2 Jan
GEMGoods3 Documents
Category: Face Mask for Underwater Training , Leg Fins for Underwater Training , Wet Suit for Training , Buoyancy Control Device BCD , Gas Regulator for Underwater Training , Cylinder for Underwater Breathing , Weight Belt for Maintaining Underwater Buoyancy , Swimming caps for under trainees , Kick board for novice under trainees , Full face mask , Inflatable swimming pool tubes for novice under trainees , Adjustable arm bands for novice under trainees , Googles for eye protection , Nose clips for novice under trainees , Ear plugs for novice under trainees , Emergency rescue hook for dead sinkers , Telescopic Safety staff rod for novice swimmers , Hydration Point , Life guard robes , Emergency First Aid Kit , Life guard chair , Rescue tubes for novice under trainees , Swimming pool cleaning net to maintain cleanliness , Outdoor digital clock for timely training , Shoe racks , Stop watch , Water Polo Ball , Water Polo Goal Post and Net
Deadline
23 Jan 2025
View Details

Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C 428; E095 A

Indian Coast Guard

SOUTH ANDAMANS, ANDAMAN & NICOBARPosted 21 Feb
GEMService4 Documents
Category: Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C 428; E095 Abnormal noise observed from AHU compartment of AC plant DIDR carried out by ship staff suspect bearings are worn out Following jobs to be undertaken a.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C 428; E096Fire and General Service pump Discharge valve not holding Valve to be repairedOverhauled and proved for satisfactory operation Size 65 NB; Service Provid.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C 428; E097Lub oil leakage observed from Stbd DA oil drain pipe line Pipe line to be renewedfabricated as sample In way jobs opening of old pipe and fitment of new .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C 428; E099Copper line of pressure gauges of following pumps Fire and Bilge pump KFWA pump FWater pump uprootedpin hole same to be renewed as per sample along with .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C 428; E100Sea water leakage observed view multiple pin holes from AC system pipe line Pipe line to be fabricatedrenewed All inway job include removal of fitted pip.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C 428; E101Hydraulic door closure for Water jet entrance door uprooted and door closure to be repaired fitment of the same with suitable fastners to be carried out .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C 428; E102Anti rust coating of both shaft from gear box to bulk head area were peeled off antirust coat to be applied on both shaftLength 04 Mtr; Service Provider , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C 428; E103Low air flow and ice formation observed on evaporator coil and air not cooling as per requirement of AC plant DI carried out by SS and found evaporator c..
Deadline
27 Feb 2025
View Details

Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C151; L001 23

Indian Coast Guard

SOUTH ANDAMANS, ANDAMAN & NICOBARPosted 5 Mar
GEMService4 Documents
Category: Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C151; L001 230 V 5 Amp15 Amp Dual poll switch socket at various places observed defectivebroken lead to non operational of socket Renewalrepair to be undertaken and.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C151; L002 Illumination light on ships name plate at Superstructure observed defective The same to be repairedrenewed and system to be proved; Service Provider , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C151; L003 10 in nos Bunk light at OfficerSOJr Sailor cabin found defective Bunk light to be repaired and system to be proved; Service Provider , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C151; E002 Both main engine shaft protection cover to be fabricated in engine room and silencerbattery Compartment Mat Wire Mess type with supporting angle Length 0.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C151; E003 Servicing pressure testing of 02 in Nos BASCCA set to be carried out by authorized firm and servicingpressure testing certificate to be provided Pressure.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C151; E004 08 in nos quick shut off valve not operating from FM 200 compartment port catwalk view loosenedbroken wire Wire to be fixed with QSV by cuttingjoining t.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C151; H001 NBCD marking Sticker Water tight marking on all Door Hatches and Air Vents Breather onboard ship are fade away same to be refurbished Same may be repairr.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C151; H002 Ship is fitted with 01 no water purifier make AOA The RO purifier generating hardnondrinkable water suspected RO purifier filter cartridge malfunction ch.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C151; H003 Port side and Stbd side Fire hoses box deteriorated and broken Same may be repair as per sample All in way job included MatFRPSS Approx size L56 cm B215 .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C151; H004 Refabrication of following Exercises Board in Bridge Same may be fabricated as per sample MatWood Size02x02x25 feet i Frequency Call Sign Board 01 No i..
Deadline
11 Mar 2025
View Details

Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C146; E033 Fu

Indian Coast Guard

SOUTH ANDAMANS, ANDAMAN & NICOBARPosted 18 Mar
GEMService4 Documents
Category: Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C146; E033 Fuel leakage Observed from FOT pump discharge pipeline view pipeline deteriorated Pipeline to be repairedrenewed as per sample In way jobs include remova.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C146; E035 AC Emergency cooling valve not holding Valve to be overhauled and proved for satisfactory In way jobs include removal and refitment and pressure testing ..
Deadline
24 Mar 2025
View Details

Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-412; E 120

Indian Coast Guard

SOUTH ANDAMANS, ANDAMAN & NICOBARPosted 4 Apr
GEMService4 Documents
Category: Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-412; E 120 Both sea chest strainers corroded and thinned down resulting in excess accumulation of sea weeds Deteriorated strainers cause insufficient sea water su.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-412; E 121 Chequered plates carpet area approx 12 mtrs in engine room and water Jet are highly rusted deteriorated All plates along with supporting base frame riv.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-412; E 122 08 in nos quick shut off valve not operating from FM 200 compartment & port catwalk view loosened broken wire Wire to be fixed with QSV by cutting join.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C 412; E 123 Sea water leakage observed in overboard flange of AC system flange to be fabricated and affixed as per sample material AL Pressure testing upto 1 5 tim.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C 412; L 131 Illumination light on ships name plate at Superstructure observed defective The same to be repaired renewed and system to be proved; Service Provider
Deadline
11 Apr 2025
View Details

Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-424; E 089

Indian Coast Guard

SOUTH ANDAMANS, ANDAMAN & NICOBARPosted 5 Apr
GEMService4 Documents
Category: Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-424; E 089 The ship is fitted 02 in number sea water collecting tray above both DAs at engine room for protect from sea water Sea water leakage observed from coll.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-424; E 067 DA emergency sea water suction line punctured and cracked at various places Same to be renewed repaired Mat SS Dia 50mm Length 2 mtr; Service Provider , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-424; H 068 Ship is fitted with 01 no water purifier make AOA The RO purifier generating hard non-drinkable water suspected RO purifier filter cartridge malfunctio.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-424; E 076 Both main engine shaft protection cover to be fabricated in engine room and silencer battery Compartment Mat Wire Mess type with supporting angle Lengt.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-424; E 093 Low air flow and ice formation observed on evaporator coil and air not cooling as per requirement of AC plant DI carried out by SS and found evaporator.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-424; E 083 Minor hydraulic oil leakage observed from eight in nos high pressure hydraulic transom flexible hoses of water jet system Requirement exists for fabric..
Deadline
12 Apr 2025
View Details

PRESSURE TESTING AND CHEMICAL CLEANING,ULTRASONIC THICKNESS TEST AND INTERNAL INSPECTION,MARKING OF

Indian Navy

SOUTH ANDAMANS, ANDAMAN & NICOBARPosted 5 May
GEMGoods3 Documents
Category: PRESSURE TESTING AND CHEMICAL CLEANING , ULTRASONIC THICKNESS TEST AND INTERNAL INSPECTION , MARKING OF PRESSURE TESTING DATES ON ALL BOTTLES AND REGULATOR , APPLICATION OF APPROPRIATE PAINT SCHEME AS MENTIONED IN DCN , CHEMICAL CLEANING AND INTERNAL INSPECTION OF DIVATOR BOTTLES , CHEMICAL CLEANING AND INTERNAL INSPECTION OF OX TEN BOTTLES
Deadline
26 May 2025
View Details