20 KW Minimum Output Wattage Required Modular N plus 1 configuration UPS of Qty 08,Battery bank con
Airports Authority Of India
Progress
Quantity
1639
Bid Type
Two Packet Bid
Public procurement opportunity for Airports Authority Of India 10 KVA N Plus 1 Modular UPS 3 phase input and single phase output as per Technical Specification with warranty of 03 three year, Battery Bank for each 10 KVA UPS as per Technical Specification with warranty of 02 two year, Metalic Battery rack as per specification having covered metalic top for both 10 KVA N Plus 1 modular UPS, Surge Protector Device SPD for 10 KVA Input 3 PHASE SPD Type I Plus TypeII DEVICES as Secondary Protection, Surge Protector Device for 10 KVA Output Supply of Single Phase SPD TYPE 2 EQUIPMENT LEVEL PROTECTION for 10 KVA N Plus 1 Modular UPS, Series Surge Filters Three Phase, 6 Sq mm 4C Power cables ISI Standard, 10 Sq mm 3C Power cables ISI Standard, MCB AC 40A 4 POLE for UPS Input, MCB AC 40A 2 POLE for UPS Output, MCB AC 06A 1 POLE for UPS Output DB, MCB AC 10A 1 POLE for UPS Output DB, 2 POLE MCB DC suitable for rating as per UPS design for 10 KVA, Battery bank to UPS joining DC cable RED, Battery bank to UPS joining DC cable BLACK, ITC work for Two 10 KVA N Plus 1 modular UPS along with SPD and Series Surge Filters, 05 KVA Conventional online UPS Single phase input and Single Phase output as per Technical Specification with warranty of 03 year five sets of UPS with load sharing configuration, UPS stand Type 1, UPS stand Type 2, Battery bank for all Ten 05 KVA UPS, Metalic Battery rack as per specification having covered metalic top for all ten 05 KVA UPS five set of UPS, Surge Protector Device TYPE 2 Single Phase, Surge Protector Device TYPE 1 Plus 2 Single Phase, Series Surge Filters Single Phase, 03 Core 04 Sq mm Power cables ISI Standard, MCB AC 32A 2 POLE, MCB AC 6A 1 POLE, 2 POLE MCB DC of suitable rating as per 5 KVA UPS design, Distribution Box with minimum 12 single pole and two double pole, ITC work for Ten 05 KVA UPS along with SPD and series surge filter, Copper Plate for earthing pit, PVC Insulated Copper Wire Multi stranded 4 sqmm, PVC pipe for earth pits, Common SALT GRANULAR about 1dash 3 cm granules, CHARCOAL GRANULAR about 1dash3 cm granules, Construction of 02 Earth pits as per defined technical specification with using matreials as per above Sr. no. 33 to Sr. no. 37. , 12 V 42AH VRLA Battery, Digital Earth Meter with all accessories, Aluminum Ladder A type, Anti Static Mat, Extension Boards in SURAT, GUJARAT. Quantity: 1639 issued by. Submission Deadline: 14-03-2025 11: 00: 00. View full details and respond.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
10 KVA N Plus 1 Modular UPS 3 phase input and single phase output as per Technical Specification with warranty of 03 three year , Battery Bank for each 10 KVA UPS as per Technical Specification with warranty of 02 two year , Metalic Battery rack as per specification having covered metalic top for both 10 KVA N Plus 1 modular UPS , Surge Protector Device SPD for 10 KVA Input 3 PHASE SPD Type I Plus TypeII DEVICES as Secondary Protection , Surge Protector Device for 10 KVA Output Supply of Single Phase SPD TYPE 2 EQUIPMENT LEVEL PROTECTION for 10 KVA N Plus 1 Modular UPS , Series Surge Filters Three Phase , 6 Sq mm 4C Power cables ISI Standard , 10 Sq mm 3C Power cables ISI Standard , MCB AC 40A 4 POLE for UPS Input , MCB AC 40A 2 POLE for UPS Output , MCB AC 06A 1 POLE for UPS Output DB , MCB AC 10A 1 POLE for UPS Output DB , 2 POLE MCB DC suitable for rating as per UPS design for 10 KVA , Battery bank to UPS joining DC cable RED , Battery bank to UPS joining DC cable BLACK , ITC work for Two 10 KVA N Plus 1 modular UPS along with SPD and Series Surge Filters , 05 KVA Conventional online UPS Single phase input and Single Phase output as per Technical Specification with warranty of 03 year five sets of UPS with load sharing configuration , UPS stand Type 1 , UPS stand Type 2 , Battery bank for all Ten 05 KVA UPS , Metalic Battery rack as per specification having covered metalic top for all ten 05 KVA UPS five set of UPS , Surge Protector Device TYPE 2 Single Phase , Surge Protector Device TYPE 1 Plus 2 Single Phase , Series Surge Filters Single Phase , 03 Core 04 Sq mm Power cables ISI Standard , MCB AC 32A 2 POLE , MCB AC 6A 1 POLE , 2 POLE MCB DC of suitable rating as per 5 KVA UPS design , Distribution Box with minimum 12 single pole and two double pole , ITC work for Ten 05 KVA UPS along with SPD and series surge filter , Copper Plate for earthing pit , PVC Insulated Copper Wire Multi stranded 4 sqmm , PVC pipe for earth pits , Common SALT GRANULAR about 1dash 3 cm granules , CHARCOAL GRANULAR about 1dash3 cm granules , Construction of 02 Earth pits as per defined technical specification with using matreials as per above Sr. no. 33 to Sr. no. 37. , 12 V 42AH VRLA Battery , Digital Earth Meter with all accessories , Aluminum Ladder A type , Anti Static Mat , Extension Boards
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Airports Authority Of India
Airports Authority Of India
RAJKOT, GUJARAT
Airports Authority Of India
LAKHIMPUR, ASSAM
Airports Authority Of India
Airports Authority Of India
Tender Results
Loading results...
10 KVA N Plus 1 Modular UPS 3 phase input and single phase output as per Technical Specification with warranty of 03 three year
As Per The Technical Specifications
Battery Bank for each 10 KVA UPS as per Technical Specification with warranty of 02 two year
As Per The Technical Specifications
Metalic Battery rack as per specification having covered metalic top for both 10 KVA N Plus 1 modular UPS
As Per The Technical Specifications
Surge Protector Device SPD for 10 KVA Input 3 PHASE SPD Type I Plus TypeII DEVICES as Secondary Protection
As Per The Technical Specifications
Surge Protector Device for 10 KVA Output Supply of Single Phase SPD TYPE 2 EQUIPMENT LEVEL PROTECTION for 10 KVA N Plus 1 Modular UPS
As Per The Technical Specifications
Series Surge Filters Three Phase
As Per The Technical Specifications
6 Sq mm 4C Power cables ISI Standard
As Per The Technical Specifications
10 Sq mm 3C Power cables ISI Standard
As Per The Technical Specifications
MCB AC 40A 4 POLE for UPS Input
As Per The Technical Specifications
MCB AC 40A 2 POLE for UPS Output
As Per The Technical Specifications
MCB AC 06A 1 POLE for UPS Output DB
As Per The Technical Specifications
MCB AC 10A 1 POLE for UPS Output DB
As Per The Technical Specifications
2 POLE MCB DC suitable for rating as per UPS design for 10 KVA
As Per The Technical Specifications
Battery bank to UPS joining DC cable RED
As Per The Technical Specifications
Battery bank to UPS joining DC cable BLACK
As Per The Technical Specifications
ITC work for Two 10 KVA N Plus 1 modular UPS along with SPD and Series Surge Filters
As Per The Technical Specifications
05 KVA Conventional online UPS Single phase input and Single Phase output as per Technical Specification with warranty of 03 year five sets of UPS with load sharing configuration
As Per The Technical Specifications
UPS stand Type 1
As Per The Technical Specifications
UPS stand Type 2
As Per The Technical Specifications
Battery bank for all Ten 05 KVA UPS
As Per The Technical Specifications
Metalic Battery rack as per specification having covered metalic top for all ten 05 KVA UPS five set of UPS
As Per The Technical Specifications
Surge Protector Device TYPE 2 Single Phase
As Per The Technical Specifications
Surge Protector Device TYPE 1 Plus 2 Single Phase
As Per The Technical Specifications
Series Surge Filters Single Phase
As Per The Technical Specifications
03 Core 04 Sq mm Power cables ISI Standard
As Per The Technical Specifications
MCB AC 32A 2 POLE
As Per The Technical Specifications
MCB AC 6A 1 POLE
As Per The Technical Specifications
2 POLE MCB DC of suitable rating as per 5 KVA UPS design
As Per The Technical Specifications
Battery bank to UPS joining DC cable RED
As Per The Technical Specifications
Battery bank to UPS joining DC cable BLACK
As Per The Technical Specifications
Distribution Box with minimum 12 single pole and two double pole
As Per The Technical Specifications
ITC work for Ten 05 KVA UPS along with SPD and series surge filter
As Per The Technical Specifications
Copper Plate for earthing pit
As Per The Technical Specifications
PVC Insulated Copper Wire Multi stranded 4 sqmm
As Per The Technical Specifications
PVC pipe for earth pits
As Per The Technical Specifications
Common SALT GRANULAR about 1dash 3 cm granules
As Per The Technical Specifications
CHARCOAL GRANULAR about 1dash3 cm granules
As Per The Technical Specifications
Construction of 02 Earth pits as per defined technical specification with using matreials as per above Sr. no. 33 to Sr. no. 37.
As Per The Technical Specifications
12 V 42AH VRLA Battery
As Per The Technical Specifications
Digital Earth Meter with all accessories
As Per The Technical Specifications
Aluminum Ladder A type
As Per The Technical Specifications
Anti Static Mat
As Per The Technical Specifications
Extension Boards
As Per The Technical Specifications
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) | Price Trends |
|---|---|---|---|---|---|---|---|
| 1 | 10 KVA N Plus 1 Modular UPS 3 phase input and single phase output as per Technical Specification with warranty of 03 three year | As Per The Technical Specifications | 2 | nos | dharasingh | 45 | |
| 2 | Battery Bank for each 10 KVA UPS as per Technical Specification with warranty of 02 two year | As Per The Technical Specifications | 2 | nos | dharasingh | 45 | |
| 3 | Metalic Battery rack as per specification having covered metalic top for both 10 KVA N Plus 1 modular UPS | As Per The Technical Specifications | 2 | nos | dharasingh | 45 | |
| 4 | Surge Protector Device SPD for 10 KVA Input 3 PHASE SPD Type I Plus TypeII DEVICES as Secondary Protection | As Per The Technical Specifications | 2 | nos | dharasingh | 45 | |
| 5 | Surge Protector Device for 10 KVA Output Supply of Single Phase SPD TYPE 2 EQUIPMENT LEVEL PROTECTION for 10 KVA N Plus 1 Modular UPS | As Per The Technical Specifications | 2 | nos | dharasingh | 45 | |
| 6 | Series Surge Filters Three Phase | As Per The Technical Specifications | 2 | nos | dharasingh | 45 | |
| 7 | 6 Sq mm 4C Power cables ISI Standard | As Per The Technical Specifications | 30 | meters | dharasingh | 45 | |
| 8 | 10 Sq mm 3C Power cables ISI Standard | As Per The Technical Specifications | 20 | meters | dharasingh | 45 | |
| 9 | MCB AC 40A 4 POLE for UPS Input | As Per The Technical Specifications | 2 | nos | dharasingh | 45 | |
| 10 | MCB AC 40A 2 POLE for UPS Output | As Per The Technical Specifications | 2 | nos | dharasingh | 45 | |
| 11 | MCB AC 06A 1 POLE for UPS Output DB | As Per The Technical Specifications | 4 | nos | dharasingh | 45 | |
| 12 | MCB AC 10A 1 POLE for UPS Output DB | As Per The Technical Specifications | 4 | nos | dharasingh | 45 | |
| 13 | 2 POLE MCB DC suitable for rating as per UPS design for 10 KVA | As Per The Technical Specifications | 2 | nos | dharasingh | 45 | |
| 14 | Battery bank to UPS joining DC cable RED | As Per The Technical Specifications | 20 | meters | dharasingh | 45 | |
| 15 | Battery bank to UPS joining DC cable BLACK | As Per The Technical Specifications | 20 | meters | dharasingh | 45 | |
| 16 | ITC work for Two 10 KVA N Plus 1 modular UPS along with SPD and Series Surge Filters | As Per The Technical Specifications | 1 | job | dharasingh | 45 | |
| 17 | 05 KVA Conventional online UPS Single phase input and Single Phase output as per Technical Specification with warranty of 03 year five sets of UPS with load sharing configuration | As Per The Technical Specifications | 10 | nos | dharasingh | 45 | |
| 18 | UPS stand Type 1 | As Per The Technical Specifications | 3 | nos | dharasingh | 45 | |
| 19 | UPS stand Type 2 | As Per The Technical Specifications | 1 | nos | dharasingh | 45 | |
| 20 | Battery bank for all Ten 05 KVA UPS | As Per The Technical Specifications | 10 | nos | dharasingh | 45 | |
| 21 | Metalic Battery rack as per specification having covered metalic top for all ten 05 KVA UPS five set of UPS | As Per The Technical Specifications | 10 | nos | dharasingh | 45 | |
| 22 | Surge Protector Device TYPE 2 Single Phase | As Per The Technical Specifications | 5 | nos | dharasingh | 45 | |
| 23 | Surge Protector Device TYPE 1 Plus 2 Single Phase | As Per The Technical Specifications | 10 | nos | dharasingh | 45 | |
| 24 | Series Surge Filters Single Phase | As Per The Technical Specifications | 10 | nos | dharasingh | 45 | |
| 25 | 03 Core 04 Sq mm Power cables ISI Standard | As Per The Technical Specifications | 200 | meters | dharasingh | 45 | |
| 26 | MCB AC 32A 2 POLE | As Per The Technical Specifications | 2 | nos | dharasingh | 45 | |
| 27 | MCB AC 6A 1 POLE | As Per The Technical Specifications | 12 | nos | dharasingh | 45 | |
| 28 | 2 POLE MCB DC of suitable rating as per 5 KVA UPS design | As Per The Technical Specifications | 10 | nos | dharasingh | 45 | |
| 29 | Battery bank to UPS joining DC cable RED | As Per The Technical Specifications | 60 | meters | dharasingh | 45 | |
| 30 | Battery bank to UPS joining DC cable BLACK | As Per The Technical Specifications | 60 | meters | dharasingh | 45 | |
| 31 | Distribution Box with minimum 12 single pole and two double pole | As Per The Technical Specifications | 1 | nos | dharasingh | 45 | |
| 32 | ITC work for Ten 05 KVA UPS along with SPD and series surge filter | As Per The Technical Specifications | 1 | job | dharasingh | 45 | |
| 33 | Copper Plate for earthing pit | As Per The Technical Specifications | 2 | nos | dharasingh | 45 | |
| 34 | PVC Insulated Copper Wire Multi stranded 4 sqmm | As Per The Technical Specifications | 100 | meters | dharasingh | 45 | |
| 35 | PVC pipe for earth pits | As Per The Technical Specifications | 2 | nos | dharasingh | 45 | |
| 36 | Common SALT GRANULAR about 1dash 3 cm granules | As Per The Technical Specifications | 240 | kg | dharasingh | 45 | |
| 37 | CHARCOAL GRANULAR about 1dash3 cm granules | As Per The Technical Specifications | 240 | kg | dharasingh | 45 | |
| 38 | Construction of 02 Earth pits as per defined technical specification with using matreials as per above Sr. no. 33 to Sr. no. 37. | As Per The Technical Specifications | 1 | job | dharasingh | 45 | |
| 39 | 12 V 42AH VRLA Battery | As Per The Technical Specifications | 24 | nos | dharasingh | 45 | |
| 40 | Digital Earth Meter with all accessories | As Per The Technical Specifications | 1 | nos | dharasingh | 45 | |
| 41 | Aluminum Ladder A type | As Per The Technical Specifications | 3 | nos | dharasingh | 45 | |
| 42 | Anti Static Mat | As Per The Technical Specifications | 500 | sqmeters | dharasingh | 45 | |
| 43 | Extension Boards | As Per The Technical Specifications | 4 | nos | dharasingh | 45 |
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
Additional Doc 1 (Requested in ATC)
Additional Doc 2 (Requested in ATC)
Additional Doc 3 (Requested in ATC)
Additional Doc 4 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
| S.No | Seller | Item | Date | Status |
|---|---|---|---|---|
| 1 | AXIS INFO Under PMA | - | 14-03-2025 10:16:48 | |
| 2 | HIND DEFENCE EQUIPMENT PRIVATE LIMITED Under PMA | - | 13-03-2025 18:08:31 | |
| 3 | INFOSOFT DIGITAL DESIGN AND SERVICES PRIVATE LIMITED Under PMA | - | 14-03-2025 07:52:35 | |
| 4 | MICROTRONICS Under PMA | - | 12-03-2025 18:25:48 | |
| 5 | NUMAX ENERGY SOLUTIONS Under PMA | - | 12-03-2025 17:24:30 | |
| 6 | PALMIRO TECHNOLOGIES PRIVATE LIMITED Under PMA | - | 14-03-2025 01:34:59 | |
| 7 | POOJA BUILDCON CONSTRUCTION Under PMA | - | 13-03-2025 22:09:47 | |
| 8 | SPRINT INTEGRATED SOLUTIONS PRIVATE LIMITED Under PMA | - | 14-03-2025 10:11:05 |
| Rank | Seller | Price | Item |
|---|---|---|---|
| L1 | SPRINT INTEGRATED SOLUTIONS PRIVATE LIMITED(MSE,MII)( MSE Social Category:OBC ) Under PMA | Item Categories : 10 KVA N Plus 1 Modular UPS 3 phase input and single phase output as per Technical Specification wi | |
| L2 | HIND DEFENCE EQUIPMENT PRIVATE LIMITED (MII) Under PMA | Item Categories : 10 KVA N Plus 1 Modular UPS 3 phase input and single phase output as per Technical Specification wi | |
| L3 | AXIS INFO Under PMA | Item Categories : 10 KVA N Plus 1 Modular UPS 3 phase input and single phase output as per Technical Specification wi |
Please sign in or create an account to view contract details and download result documents.
Key insights about GUJARAT tender market
The eligibility requirements include being a registered entity with a valid GST number, demonstration of experience in supplying and installing UPS systems of similar capacity, and compliance with quality standards. Potential bidders must also be capable of providing warranty support for both the UPS and the battery bank. Documentation proving the above eligibility must be submitted with the proposal.
The technical specifications require the provision of a 10 KVA N Plus 1 Modular UPS system, inclusion of surge protection devices, and adherence to ISI standard cables. Bidders must ensure that all equipment meets safety standards and comes with necessary certifications. Additionally, all installations must follow industry best practices for robust and reliable operation.
The Earnest Money Deposit (EMD) details will be specified in the tender documentation. Typically, the EMD serves as a guarantee to ensure commitment from the bidders and may vary based on project scope. Bidders are advised to confirm the specific requirements within their tender documents to prevent any miscommunication or oversight.
Micro, Small, and Medium Enterprises (MSEs) can benefit from this tender through provisions designed specifically to enhance their participation. These include relaxed eligibility criteria and potential financial relief in terms of reduced bid security or assistance with compliance requirements. Interested MSEs must provide necessary documentation to avail of these benefits.
Submissions must be made electronically via the official bidding portal. All documents should be submitted in the specified format, ensuring compliance with all outlined criteria. Key timelines, including submission deadlines and bid opening dates, will be detailed in the official tender notice and should be carefully noted for alignment with all requirements.
Airports Authority Of India ,rhq Nr - Rangpuri
Indian Army
📍 INDORE, MADHYA PRADESH
Hindustan Petroleum Corporation Ltd
📍 GORAKHPUR, UTTAR PRADESH
Patratu Vidyut Utpadan Nigam Limited
📍 HAZARIBAG, JHARKHAND
Indian Army
📍 BISHNUPUR, MANIPUR
Sign up now to access all documents
Main Document
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS