Hospital Medical Education invites bids for Ultrasound Machine (V2) (Q2) in AIZAWL, MIZORAM. Quantity: 1. Submission Deadline: 05-03-2026 11: 00: 00. Submit your proposal before the deadline.
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Iocl- Wrpl
Oil India Limited
DIBRUGARH, ASSAM
N/a
BILASPUR, CHHATTISGARH
N/a
U.p.rural Institute Of Medical Sciences And Research Saifai
ETAWAH, UTTAR PRADESH
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| GENERAL | Product Description | Ultrasound Machine |
| Types of Probes & Features | Applications | Abdomen, Abdominal vascular, Urology, OB/GYN, Neonatal brain, Small parts (breast, thyroid, scrotal, prostate, musculoskeletal) |
| Types of Probes & Features | Convex Probe | 2.5 to 5 MHz (±2) |
| Types of Probes & Features | Microconvex probe | Not Provided |
| Types of Probes & Features | Linear array probe | 6 to 15 MHz (±2) |
| Types of Probes & Features | TVS Probe | 4 to 9 MHz (±2) |
| Types of Probes & Features | Cardiac Probe | Not Provided |
| Types of Probes & Features | Hockey Stick Probe | Not Provided |
| Types of Probes & Features | Volume Convex Probe | Not Provided |
| Types of Probes & Features | Volume Linear Probe | Not Provided |
| Types of Probes & Features | Volume TVS Probe | Not Provided |
| Types of Probes & Features | Endorectal Probe | Not Provided |
| Types of Probes & Features | E-Breast Elastography technique | No |
| Types of Probes & Features | E-Thyroid Elastography technique | No |
| Types of Probes & Features | Liver Elastography technique | No |
| Types of Probes & Features | Gel Warmer | No |
| Types of Probes & Features | Dedicated 3-D/4-D | Yes, No |
| Scan Modes | B-mode | Yes |
| Scan Modes | M-mode | Yes |
| Scan Modes | Contrast harmonic imaging with angio mode | No |
| Scan Modes | Tissue harmonic imaging mode | Yes |
| Scan Modes | Provision of Harmonic imaging in Linear Probes | No |
| Scan Modes | Color Doppler imaging (CDI) | Yes |
| Scan Modes | Color Doppler 3-D/4-D option | No |
| Scan Modes | Power Doppler imaging (PDI) | Yes |
| Scan Modes | Power Doppler 3-D/4-D option | Yes, No |
| Scan Modes | Continuous wave | No |
| Scan Modes | Pulsed wave | Yes |
| Scan Modes | Duplex mode | Yes |
| Scan Modes | Triplex mode | No |
| Scan Modes | Tissue Doppler imaging | No |
| Scan Modes | Contrast-enhanced ultrasound (CEUS) option | No |
| Scan Modes | Tissue synchronization, tissue velocity | No |
| Scan Modes | Provision for higher sensitivity for low frequency doppler in all probes | Yes |
| Scan Modes | Number of channels in color doppler system | 300000 or more (if channels are being designated as digital channels) |
| Scan Modes | Live 3 D imaging in color doppler system | Yes, No |
| Scan Modes | Colour Doppler system with all application packages ,Quad loop for serial studies with high frame rate revies, harmonic imaging capability in all modes and integrated stress echo package digital storage and retrieval | No |
| Scan Modes | Number of grey shades for sharp contrast resolutions in db | 256 or more |
| Scan Modes | High-definition acoustic zoom provision for enlarging sections of 2D and Colour flow images with more acoustic information for greater clarity and detail while maintaining an optimal frame rate | Yes |
| Scan Modes | Colour Flow Imaging Option | Yes |
| Scan Modes | Provision of Tissue Colorization (B-Colour) for improved contrast resolution | No |
| Scan Modes | All application packages should be inbuilt into the system | Yes |
| Scan Modes | Cine Loop Features | Yes |
| Scan Modes | Cine Loop Memory in MB | >=100 |
| Scan Modes | Frame grabber facility for post analysis | No |
| Scan Modes | User defined system and application presets for multi-user department | Yes |
| Scan Modes | Number of transducer/probe ports | 4 or More |
| Scan Modes | System should be capable of generating real time live 3- D images | No |
| Scan Modes | Contrast agent imaging | No |
| Image Display and Processing | DICOM 3 Compliant | Yes |
| Image Display and Processing | Automated B-mode (2-D) image | Yes |
| Image Display and Processing | Automated CDI(Color Doppler Imaging) image optimization | Yes |
| Image Display and Processing | Automated PW Doppler image optimization | Yes |
| Image Display and Processing | Grayscale levels | 256 |
| Image Display and Processing | Image magnification (zoom) | Yes |
| Image Display and Processing | Real-time image | Yes |
| Image Display and Processing | Touch Screen | Yes, No |
| Image Display and Processing | Monitor shall have high-resolution | Yes |
| Image Display and Processing | Monitor display size (inch) | 21 or more Or higher |
| Image Display and Processing | Split screen | Twin View |
| Image Display and Processing | Single/dual monitors | Single, Single with optional second console, Dual (image display and touch panel) |
| Image Display and Processing | Depth, cm | ≥30 |
| Image Display and Processing | Pre processing | Yes |
| Image Display and Processing | Post processing | Yes |
| Image Display and Processing | Selectable dynamic range (dB) | >=275 |
| Image Display and Processing | Spectrum analyzer | Yes |
| Image Display and Processing | Digital Image Storage | Yes |
| Image Display and Processing | Cine loop playback | Yes |
| Image Display and Processing | Max number frames | >=1000 |
| Image Display and Processing | Digital storage hard drive, GB | >=500 |
| Image Display and Processing | DVD/CD Writer/ USB | Yes |
| Image Display and Processing | Flash Memory | Yes |
| Image Display and Processing | USB connector | Yes |
| Image Display and Processing | Facility for high definition digital acquisition, review and editing of complete patient studies | Yes |
| Image Display and Processing | Type of processor (in PC) | NA |
| Image Display and Processing | RAM capacity of PC in GB (hint: In case PC not provided put zero) | NA |
| Image Display and Processing | Processor speed in GHz (PC) | NA |
| Image Display and Processing | Frame Grabber incorporated(PC) | No |
| Image Display and Processing | Connectivity between USG and PC | No |
| Image Display and Processing | PC with all software inclusive interfaced with USG machine | No |
| Image Display and Processing | Laser Color printer provided | No |
| Image Display and Processing | Inkjet/Thermal printer provided | No |
| Image Display and Processing | CD/DVD/USB Produced should be playable on any system | No |
| Image Display and Processing | Glossy Colour Print Paper supplied | NA |
| Image Display and Processing | Dicom Interfacability Dicom to PACS | No |
| Image Display and Processing | Interfacability Dicom to RIS | No |
| Power Requirements | Power input, VAC | 220-240VAC, 50Hz fitted with Indian plug |
| Power Requirements | Resettable over current breaker shall be fitted for protection | Yes |
| Power Requirements | Power backup | UPS |
| Power Requirements | Back up time in minutes (minimum) | 30.0 |
| Power Requirements | Suitable Servo Controlled Stabilizer / CVT should be provided | No |
| Certifications | Compliance to Medical Device Rules (MDR) 2017 as amended till date | Yes |
| Certifications | Availability of valid drug/Medical Device license for the product issued from the competent authority defined under Drugs and Cosmetic Act 1940 and Rules made there under as amended till date | Yes |
| Certifications | Certification for manufacturing unit | ISO:13485 (Latest) |
| Certifications | Availability of Test Report for each supplied batch/product as per Medical Device Rule (MDR) 2017 as amended till date | Yes |
| Certifications | Submission of all necessary certifications, licenses and test reports to the buyer at the time of bid submission or along with supplies as per buyer requirement | Yes |
| Certifications | Electrical Safety standards | IEC-60601-1-1 or equivalent BIS |
| Warranty and Maintenance | Warranty in Years (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) | 5 Or higher |
| Miscellaneous Requirements | OEM/Reseller shall ensure uninterrupted availability of all spares, consumables and reagents for atleast 10 years | Yes |
| Miscellaneous Requirements | Availability of toll free facility for technical support maintened by OEM or authorized agencies | Yes |
| Miscellaneous Requirements | User/Technical/Maintenance manuals to be provided in English in hard and soft copy | Yes |
| Miscellaneous Requirements | Details of equipments and procedures required for local calibration and routine maintenance to be provided and advanced maintenance task documentation also to be furnished | Yes |
| Miscellaneous Requirements | Supplier to perform installation, safety and operation checks before handover | Yes |
| Miscellaneous Requirements | Training of users in operation and basic maintenance shall be provided | Yes |
| Miscellaneous Requirements | Contact details of manufacturer, supplier and local service agent to be provided | Yes |
| Miscellaneous Requirements | Certificate of calibration from the manufacturer | Yes |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Extended Deadline
05-Mar-2026, 11:00 am
Opening Date
05-Mar-2026, 11:30 am
Extended Deadline
02-Mar-2026, 11:00 am
Opening Date
02-Mar-2026, 11:30 am
West Bengal Medical Services Corporation (wbmsc) Kolkata
📍 NORTH 24 PARGANAS, WEST BENGAL
All India Institute Of Medical Sciences (aiims)
📍 GORAKHPUR, UTTAR PRADESH
Aligarh Muslim University (amu)
📍 ALIGARH, UTTAR PRADESH
U.p.rural Institute Of Medical Sciences And Research Saifai
📍 ETAWAH, UTTAR PRADESH
All India Institute Of Medical Sciences (aiims)
📍 BATHINDA, PUNJAB
Sign up now to access all documents
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS